4 April 2014

FA9101-14-R-0005

SURFACE COOLER TUBE BUNDLES

Per Drawing # TUL-4321, the following questions and answers are provided.

Q1. What are the thickness for the 3 baffles?

A1. According to the drawings: 3/8" thick

Q2. What are the thickness for the 2 tube-sheets?

A2. According to the drawings: 1" thick

Q3. Are you rolling both tubes' into the tube-sheets and 3 baffles or you just interested in rolling the tubes' into 2 tube-sheet's?

A3. The tubes are rolled into the tube sheets, only. The baffles are used as spacers.