This document is a List of Materials (LOM) for contract FA875125Q0148, updated on 21AUG25, specifying fiber optic cable requirements on a brand name or equal basis. The list includes 20 line items of specialized optical fiber from manufacturers like Fibercore, Corning, and others, with varying specifications such as fiber type (SM300, SM450, SM600, Hi 780, Hi 1060, PM S350-HP, PM 980), connector types (APC to APC, APC to UPC), and lengths ranging from 2 to 80 meters. The fibers are specified with precise technical details including core diameter, numerical aperture, jacket material (predominantly 900um OD Hytrel in blue or red, with one 3mm OD black PVC option), and specific connector alignment characteristics. Quantities range from 2 to 6 units per line item, totaling approximately 54 fiber optic cables with different technical configurations intended for specialized optical applications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| QA 2 25AUG25.pdf | ||
| QA 1 21AUG25.pdf | ||
| Attch 2 - Offeror Representations and Certifications.pdf | ||
| Attch 1 - 25q148 - List of Materials.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FA875125Q0148
Attch 1 – List of Materials (LOM) Updated 21AUG25
The following items are required on a brand name or equal basis:
1). SM300 Fiber, APC to APC, L = 8 meters. S-FAkFUk-2.2f/125/.9bu-8. QTY = 6 Narrow Key, 300 to 360 um Long End-Cap (Both Ends) on Fibercore SM300 Fiber, 900um OD Blue Hytrel Tubing, NA at 405nm @ D4Sigma: 0.07 - 0.1
2). SM 300 Fiber, APC to UPC, L = 8 meter. S-FAkFAk-2.2f/125/.9bu-8, QTY = 6 Narrow Key, 300 to 360um Long End-Cap (Both Ends) on Fibercore SM300 Fiber, 900um OD Blue Hytrel Tubing, NA at 405nm @ D4Sigma: 0.07 - 0.1
3). PM S350-HP fiber, APC to UPC, L = 8 meters. P-FAnskFUnsk-2.3n/125/.9bu-8. QTY = 4 Narrow Key, Slow A�is Alignment, 295 to 355um Long End-Cap (Both Ends) on PM-S350-HP Fiber, 900um OD Blue Hytrel Tubing, NA at 405nm @ D4Sigma: 0.07 - 0.1
4). PM S350-HP fiber APC to APC, L = 8 meters. P-FAnskFAnsk-2.3n/125/.9bu-8. QTY = 4 Narrow Key, Slow A�is Alignment, 295 to 355um Long End-Cap (Both Ends) on PM-S350-HP Fiber, 900um OD Blue Hytrel Tubing, NA at 405nm @ D4Sigma: 0.07 - 0.1
5). SM450 fiber, APC to APC, L = 4 meters. S-FAFA-3.8f/125/.9bu-4. QTY = 6 Fibercore SM450 Fiber in 900um OD Blue Hytrel Jacket, 6). SM450 fiber, APC to APC, L = 8 meters. S-FAFA-3.8f/125/.9bu-8. QTY = 3 Fibercore SM450 Fiber in 900um OD Blue Hytrel Jacket
7). SM450 fiber APC to APC L = 2 meters. S-FAFU-3.8f/125/.9bu-2. QTY = 4 Fibercore SM450 Fiber in 900um OD Blue Hytrel Jacket
8). SM600 fiber APC to APC L = 4 meters. S-FAFA-4f/125/.9r-4. QTY = 4 Fibercore SM600 Fiber in 900um OD Red Hytrel Jacket, 9). SM600 fiber APC to APC L = 8 meters S-FAFA-4f/125/.9r-8. QTY = 3 Fibercore SM600 Fiber in 900um OD Red Hytrel Jacket
10). SM600 fiber APC to UPC L = 2 meters S-FAFU-4f/125/.9r-2 QTY = 4 Fibercore SM600 Fiber in 900um OD Red Hytrel Jacket
11). Corning Hi 780 fiber APC to APC L = 4 meters S-FAFA-5c/125/.9r-4 QTY = 4 Corning Hi 780 Fiber in 900um OD Red Hytrel Jacket
12). Corning Hi 780 fiber APC to APC L = 8 meters S-FAFA-5c/125/.9r-8 QTY = 2 Corning Hi 780 Fiber in 900um OD Red Hytrel Jacket
13). Corning Hi 780 fiber APC to APC L = 4 meters S-FAFA-5c/125/.9r-2 QTY = 2
FA875125Q0148
Attch 1 – List of Materials (LOM) Updated 21AUG25
Corning Hi 780 Fiber in 900um OD Red Hytrel Jacket
14). Corning Hi 1060 fiber APC to APC L = 4 meters S-FAFA-7c/125/.9r-4 QTY = 4 Corning Hi1060 Fiber in 900um OD Red Hytrel Jacket
15). Corning Hi 1060 fiber APC to APC L = 8 meters S-FAFA-7c/125/.9r-8 QTY = 2 Corning Hi1060 Fiber in 900um OD Red Hytrel Jacket
16). Corning Hi 1060 fiber APC to APC L = 2 meters S-FAFA-7c/125/.9r-2 QTY = 4 Corning Hi1060 Fiber in 900um OD Red Hytrel Jacket
17). PM 980 fiber APC to APC L = 4 meters P-FAnsFAns-6c/125/.9r-4 QTY = 2 Narrow Key, Slow Axis Aligned Connectors, Corning PM980 Fiber in 900um OD Red Hytrel Jacket
18). PM 980 fiber APC to APC L = 2 meters P-FAnsFAns-6c/125/.9r-2 QTY = 2 Narrow Key, Slow Axis Aligned Connectors, Corning PM980 Fiber in 900um OD Red Hytrel Jacket
19). Corning Hi 1060 fiber APC to APC L = 80 meters S-FAFA-7c/125/3bl-80 QTY = 4 Corning Hi1060 Fiber in 3mm OD Black PVC Jacket
20). PM 980 fiber APC to APC L = 80 meters P-FAnsFAns-6c/125/.9r-80 QTY = 4 Narrow Key, Slow Axis Aligned Connectors, Corning PM980 Fiber in 900um OD Red Hytrel Jacket