Building 106 FAC.pdf
PDF 1 MB Posted
- Attached to
- Fire Alarm, Mass Notification, Fire Suppression Inspection/Testing/Maintenance Federal contract opportunity
- Solicitation number
- FA875122R0003
About this file
This is a solicitation for fire alarm, mass notification, and fire suppression inspection, testing, and maintenance services. The contractor shall provide these services on a firm fixed price basis at specified facilities in Rome, New York, for a one-year period beginning January 1, 2022 with four optional one-year extensions. This procurement is set aside for service-disabled veteran-owned small businesses. Proposals are due by December 24, 2021 and shall be submitted electronically. The award will be made to the lowest priced technically acceptable offeror with no negative past performance based on technical acceptability, price, and past performance evaluation.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Building 2 FAC.pdf | ||
| Fire Supression - All Buidlings.pdf | ||
| Building 101 FAC.pdf | ||
| B1609 Upper Mezz Sprinkler Plan.PNG | PNG image | |
| B1609 First Floor Fire Alarm System.PNG | PNG image | |
| B1609 Upper and Lower Mezzanine Fire Alarm Sys.PNG | PNG image | |
| B1610 Fire Pump Details.PNG | PNG image | |
| B1609 LowerMezz Sprinkler Plan.PNG | PNG image | |
| Building 1 FAC.pdf | ||
| Building 3 FAC.pdf | ||
| Building 1480 FAC.pdf | ||
| Building 1477 FAC.pdf | ||
| B1609 First Floor Sprinkler Plan.PNG | PNG image | |
| Attach 3_PPQ.pdf | ||
| Attach 4_Bid Schedule.pdf | ||
| Attach 2_Offeror Representations and Certifications.pdf | ||
| Attach 1_Fire Alarm_MNS_ Fire Suppression PWS.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M a tc hl in e
T hi s
S he et
M a tc hl in e
T hi s
S he et
Syracuse, NY 13206 2201 Burnet Avenue
Fax 315−463−5006 Ph. 315−433−1234
Endicott, NY 13760 428 East Main Street
Ph. 607−722−3200 Fax 607−722−2124
Syracuse Time & Alarm Co., Inc.
"Our Concern Makes the Difference"
R
R
REQUIREMENTS:
Drawing Number: Revision:
D5794
Scale: (Sheet 24" x 36")
Project Number:
Date:
Approved By:
Checked By:
Drawn By:
26−Sep−2011
1/16" = 1’−0"
WAR
MJS
MSR
12000032805
N.Y.S. LICENSE#
PLOTTED
R E V
IS
IO
N
N O
D A T E
A
DATE
REVIEW TO SPECIFICATION
COMPANY FIELD ADVISOR
B C D E F G H J http://www.syrtime.com
A B C D E F G H J
Sheet:
21−Jul−14 provided to Syracuse Time & Alarm Co., Inc. (STA) as an aid for the installation using documentation and specifications. These drawings were produced utilized in conjunction with the contract plans be an installation drawing by itself. It shall be This is a typical drawing and is not intended to functionality. All questions or concerns must be equipment, plans, scope of the system or STA assumes no responsibility for changes in or to equipment manufacturer.
submitted in writing to an STA representative
The information contained in this document is the information contained on them shall not be authorized personnel only. These drawings and property of STA and is intended solely for use by permission by an authorized STA official only.
distributed to others without prior written
R om e R es ea rc h L a b
B ui ld in g
R om e, N ew Y or k
F ir e
A la rm
M a ss
N ot if ic a ti on
F ir st
F lo or
RTS
DT
S116L1 P1 air supply
RTS
P1 return air
RTS
DT
S115L1
P1
DT
S112L1
P1
RTS
P1 ahu−1s
RTS
DT
S110L1 P1 ahu−s
RTS
DT
S111L1
P1
RTS
DT
S101L1 RTS
DT
S109L1
DT
S108L1
P1ahu−r
RTS
P1 pecs−r
DH
DH
DH
DHDH
DH
DH
DH DH
DH
DH
DHDH
DH
DH
DH
DH
NGA − Node 3 VGC − Node 4
#1
LOC
LO
C
#10
LOC
LO
C
#8
LOC
#6
LOC
#7
LOC
LO
C
LO
C
LO
C
LO
C
L1S035
L1S034
L1S033
L1S032
L1S031
L1 S030
L1S029
L1S028
L1S027
L1S026
L1S024
L1S023
L1S022
L1S021
L1 S020
L1S019
L1S018L1S017
L1S016
L1S015
L1S014
L1S013
L1S012 L1S011
L1S010
L1S009
L1S002
L1S037 L1S036
L1S001
#12
LOC
NA
C
NA
C
NA
C
AMM4F
M003L1
AMM4F
M002L1
AMM4F
M011L1
AMM4F
M008L1
F M001L1
1 W
SPK 4−2
W
SPK 3−1 W
AMM4F
M007L1
AMM4F
M006L1
AMM4F
M005L1
AMM4F
M004L1
AMM4F
M012L1
V NAC 2−2
DT
S100L1
DT
S117L1
DT
S105L1
DT
S114L1
DH
L1S038 in pit
L1S039
135F
S040L1
AOM2SF primary recall
M082L1
AOM2SF alternate recall
M083L1
AOM2SF fireman’s hat
M080L1
AOM2SF shunt trip
M081L1
FA
CP #
FA
CP
1 W
NAC 3−3
SPK 2−1 S
1/2 W
NAC 1−1
SPK 2−1
S30
NAC 1−3 M
N27L1S041 in pit
L1S043
135F
S044L1
AOM2SF primary recall
M084L1
AOM2SF alternate recall
M085L1
AOM2SF fireman’s hat
M086L1
AOM2SF shunt trip
M087L1
Elevator Controls
AMM4F
M015L1
NAC 1−1
SPK 4−2
S
NAC 2−2
SPK 3−1SNAC 2−4 M
NAC 2−3
M
NAC 2−2
SPK 3−1
S
NAC 2−4M
NAC 2−2
SPK 3−1 S
NAC 2−4M
NAC 2−2
SPK 3−1
S
NAC 2−4M
NAC 2−1
SPK 3−2 S NAC 2−3M
1/2 W
NAC 2−2
SPK 3−1
S
NAC 2−4M
NAC 2−1
SPK 3−2S
NAC 2−1
SPK 3−2
S
NAC 2−3M
NAC 2−1
SPK 3−2
SV NAC 2−1
NAC 2−3M
NAC 2−1
SPK 3−2 S
NAC 2−1
SPK 3−2SNAC 2−3 M
NAC 2−1
SPK 3−2 S NAC 2−3M
NAC 2−1
SPK 3−2 S
NAC 2−1
SPK 3−2S
NAC 2−3
M
NAC 2−3
M
NAC 2−1
SPK 3−2 S
NAC 2−3M
NAC 2−1
SPK 3−2S
1/2 W
NAC 2−1
SPK 3−2
S
NAC 2−3 M
1/2
NAC 2−1
SPK 3−2S
NAC 2−3
M
NAC 2−3 M
1/2 W
NAC 2−1
SPK 3−2
S
NAC 2−1
SPK 3−2S
NAC 2−3M
NAC 2−1
SPK 3−2S
NAC 2−3M
NAC 2−1
SPK 3−2S
NAC 2−3M
NAC 2−1
SPK 3−2S
NAC 2−3M
NAC 2−2
SPK 3−1
S
NAC 2−4M
NAC 2−2
SPK 3−1S
NAC 2−4M
NAC 2−2
SPK 3−1S
NAC 2−4M
NAC 2−2
SPK 3−1S
NAC 2−4M
NAC 2−2
SPK 3−1S
NAC 2−4M
NAC 2−2
SPK 3−1S
NAC 2−4M
NAC 2−2
SPK 3−1 S
NAC 2−2
SPK 3−1 S
NAC 2−2
SPK 3−1S
NAC 2−4M
NAC 2−2
SPK 3−1S
NAC 2−4M
NAC 2−2
SPK 3−1S
NAC 2−4M
NAC 2−2
SPK 3−1S
NAC 2−4M
NAC 2−2
SPK 3−1S
NAC 2−4M
NAC 2−2
SPK 3−1S
NAC 2−4M
NAC 4−1
SPK 1−2S
NAC 4−3M
NAC 2−2
SPK 3−1SNAC 2−4 M
NAC 4−1
SPK 1−2S
NAC 4−1
SPK 1−2 S
NAC 2−4MNAC 2−2
SPK 3−1 S
NAC 4−1
SPK 1−2 S
NAC 1−1
SPK 4−2S
NAC 1−1
SPK 4−2S
NAC 1−3M
NAC 3−2
SPK 2−2S
NAC 3−4
M
NAC 1−1
SPK 4−2
S
NAC 1−3M
NAC 1−3M
NAC 3−2
SPK 2−2 S NAC 3−4M
NAC 3−2
SPK 2−2SNAC 3−4 M
NAC 3−1
SPK 2−2
S
NAC 3−3M
1/2 W
NAC 1−1
SPK 4−2
S
NAC 1−3 M
NAC 1−1
SPK 4−2
S
NAC 1−3M
NAC 1−1
SPK 4−2
S
NAC 1−1
SPK 4−2S
NAC 1−3
M
NAC 1−1
SPK 4−2S
NAC 1−3M
NAC 1−1
SPK 4−2S
NAC 1−1
SPK 4−2S
NAC 1−1
SPK 4−2
S
NAC 1−3M
NAC 1−1
SPK 4−2
S
NAC 1−3M
NAC 1−2
SPK 4−1
S
NAC 1−2
SPK 4−1
S
NAC 1−4M
NAC 1−4M
NAC 1−2
SPK 4−1S NAC 1−2
SPK 4−1S
NAC 1−2
SPK 4−1
S
NAC 1−2
SPK 4−1S
NAC 1−4M
NAC 1−4M
NAC 1−4M
NAC 1−2
SPK 4−1
S
NAC 1−4M
NAC 1−2
SPK 4−1
S
NAC 1−4M
NAC 1−2
SPK 4−1
S
NAC 1−4M
NAC 1−2
SPK 4−1
S
NAC 1−4M
NAC 1−2
SPK 4−1
S
NAC 1−2
SPK 4−1
S
NAC 1−2
SPK 4−1SNAC 1−4 M
NAC 1−2
SPK 4−1S
NAC 1−4M
NAC 1−2
SPK 4−1
S
NAC 1−2
SPK 4−1
S
NAC 1−1
SPK 4−2 S
NAC 1−1
SPK 4−2 S
NAC 1−1
SPK 4−2
S
NAC 1−3M
NAC 1−1
SPK 4−2
S
NAC 1−3
M
NAC 1−2
SPK 4−1
S
NAC 1−4
M
NAC 1−1
SPK 4−2S
NAC 1−1
SPK 4−2S
NAC 1−1
SPK 4−2S
NAC 1−3
M
NAC 1−2
SPK 4−1S
NAC 3−1
SPK 2−2
S
NAC 3−3M
NAC 3−3M
NAC 3−1V
NAC 3−3M
1/2 W
NAC 3−1
SPK 2−2
S
1 W
NAC 3−2
SPK 2−1
S
NAC 3−4M
NAC 3−1
SPK 2−2 S
NAC 3−1
SPK 2−2
S
NAC 3−3M
NAC 4−1
SPK 2−2S
NAC 3−1
SPK 2−2S
NAC 1−1
SPK 2−1S
NAC 1−3M
NAC 3−1
SPK 2−2 S
NAC 3−1
SPK 2−2SNAC 3−3 M
NAC 3−1
SPK 2−2S
NAC 1
SPK 1S
NAC 2M
NAC 3−2
SPK 2−1 S
NAC 1
SPK 1S
NAC 2M
NAC 3−2
SPK 2−1S
NAC 3−4M
NAC 3−2
SPK 2−1S
NAC 3−4M
NAC 3−2
SPK 2−1S
NAC 3−2M30
1/2 W
NAC 3−2
SPK 2−1
S
NAC 3−4 M
1 W
NAC 3−2
SPK 2−1
S
NAC 3−4M
NAC 3−2
SPK 2−1 S
NAC 3−2
SPK 2−1
S
NAC 3−3M
1 W
NAC 3−1
SPK 2−2
S
NAC 4−4M
1 W
NAC 4−2
SPK 1−1
S
NAC 4−3 M
1 W
NAC 4−1
SPK 1−1
S
NAC 4−2
SPK 1−1S
NAC 4−4
M
NAC 4−2
SPK 1−1S
NAC 4−2
SPK 1−1 S
NAC 4−2
SPK 1−1 S
NAC 4−2
SPK 1−1S
NAC 4−4
SPK 1−1 S
NAC 4−2M
NAC 4−2
SPK 1−1
S
NAC 4−4M
1 W
NAC 4−2
SPK 1−1
S
NAC 4−4M
NAC 4−2
SPK 1−1 S NAC 4−4M
1 W
NAC 4−2
SPK 1−1
S
NAC 4−4M
NAC 4−2
SPK 1−1 S
NAC 4−4 M
1 W
NAC 4−1
SPK 1−2
S75
NAC 4−3 M
NAC 4−4 MNAC 4−4M
NAC 4−2
SPK 1−1S
NAC 4−4M
NAC 4−2
SPK 1−1 SNAC 4−2
SPK 1−1S
NAC 4−2
SPK 1−1S
NAC 4−4M
NAC 4−2
SPK 1−1S
NAC 4−4M
NAC 4−4 M NAC 4−2
SPK 1−1SNAC 4−1
SPK 1−2S
NAC 4−3M
1 W
NAC 4−1
SPK 1−2S75
NAC 4−3 M
NAC 2−2
SPK 3−1
S
NAC 2−4M
1/2 W
NAC 4−1
SPK 1−2
S
NAC 4−1
SPK 1−2SNAC 4−3 M NAC 4−1
SPK 1−2S
NAC 4−3M
NAC 4−3 M
NAC 4−1
SPK 1−2
S
NAC 4−3 M 75
1 W
NAC 4−1
SPK 1−2
S
NAC 4−1
SPK 1−2S
NAC 4−1
SPK 1−2S
NAC 4−3M
1/2 W
NAC 4−1
SPK 1−2
S
NAC 4−3 M
NAC 3−4M
1 W
NAC 3−2
SPK 2−1
S
NAC 4−3M
1/2 W
NAC 4−1
SPK 1−2
S
NAC 4−3M
1 W
NAC 4−1
SPK 1−2
S75
1 W
NAC 4−1
SPK 1−2
S
1 W
NAC 4−1
SPK 1−2
S
NAC 4−3 M
NAC 4−3 M
SPK 3−2
M
SPK 3−2
M
SPK 3−2
M
SPK 3−2
M
SPK 3−1
MSPK 3−2
M
SPK 3−2
M
SPK 3−1
M
SPK 3−1
M
SPK 3−1
M
SPK 3−2
M
SPK 3−2
M
SPK 3−2
M
SPK 3−2
M
SPK 3−2
M
SPK 3−2
M
SPK 3−2
M
SPK 3−2
M
SPK 3−2
M
SPK 3−2
M SPK 3−2
M
SPK 3−2
M
SPK 3−2
M
SPK 3−2
M
SPK 3−1
M
SPK 3−1
M
SPK 3−1
M
SPK 3−2
M
SPK 3−2
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 2−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−2
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 3−2
M
SPK 3−2
M
SPK 3−2
M
SPK 3−2
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−2
M
SPK 3−1
M
SPK 3−1
M
SPK 3−1
M
SPK 3−1
M
SPK 3−1
M
SPK 1−2
M
SPK 1−2
M
SPK 1−2
M
SPK 1−2
M
SPK 1−2
M
SPK 1−2
M
SPK 1−2
M
SPK 3−1
M
SPK 3−1
M
SPK 2−2
M
SPK 2−2
M
SPK 4−1
M
SPK 4−1
M
SPK 2−2
M
SPK 2−1
M
SPK 2
M
SPK 2−1
M
SPK 2−1
M
SPK 1
M
SPK 2−2
M
SPK 4−2
M
SPK 4−2
M
SPK 2−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−1
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
MSPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
MSPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 4−2
M
SPK 2−1
M
SPK 2−2
M
SPK 3−1
M
SPK 1−2
M
SPK 1−2M
SPK 3−1
M
SPK 1−2
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−2
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1
M
SPK 1−1W
1 W
SPK 1−2
W
SPK 1−1
W
1 W
SPK 1−1W
1 W
SPK 2−1W
1 W
SPK 4−2W
1 W
SPK 4−2W
1 W
SPK 3−2 W
1 W
SPK 3−1W
1 W
SPK 1−2
W
SPK 3−1
M
FS sprinkler riser #123
FS sprinkler riser #124
FS sprinkler riser #125a
FS sprinkler riser #121
FS sprinkler riser #122
FS sprinkler riser #120
FS sprinkler riser #125
FS sprinkler riser #125
PAM−1
Remote Annunciator
NGA, ASM−16,
INCC−MIC
Addressable Output Relay Control Module AOM−2RF
E3Fire Alarm Control Panel
NAC Expander Panel HPFF12
AOM−2SFAddressable Output Relay Supervised Control Module
Magnetic Door Holder DHF−24120C
DNR w/
ASD−PL2FR
Addressable Photoelectric Smoke Sensor w/ Base
ASD−PL2F &
B210LP
Speaker Strobe (15 candela, 1/4 watt U.O.N.)
SPSR
Remote Test Station Test & Reset Switch w/ Alarm LED
RTS151
SYMBOL LIST
SYMBOL DESCRIPTION MODEL
Sprinkler System Tamper Switch By Others
Sprinkler System Flow Switch
Dry−Pipe Sprinkler System Pressure Switch By Others
Strobe, Ceiling Mounted (30 candela U.O.N.)
SCR
Speaker Strobe, Ceiling Mounted (30 candela, 1/4 watt U.O.N.)
SPSCR
Relay Module
Addressable Photoelectric Duct Smoke Detector w/ Remote Test Capability
Addressable Monitor Module, Class A AMM−4F
DT
AOM2RF
AOM2SF
AMM4F
TS
FS
P1
PS
FACP
LOC
NAC
S
V
S
DH
RTS
By Others
Mass Notification Speaker Strobe (15 candela, 1/4 watt U.O.N.)
SPR
Mass Notification Strobe with Amber Lens (15 candela U.O.N.)
SW−P
Mass Notification Strobe with Amber Lens Ceiling Mounted (30 candela U.O.N.)
SCW−P
Mass Notification Speaker Strobe, Ceiling Mounted (1/4 watt U.O.N.)
SPSCRM
M
M
M
Mass Notification Speaker Only, Ceiling Mounted (1/4 watt U.O.N.)
SPCWM
W Mass Notification Speaker Only, Weatherproof (1 watt U.O.N.)
SPSRK
Addressable Double−Action Manual Station MS−7AFF
Mass Notification Strobe with Amber Lens Weatherproof (110 candela U.O.N.)
SWK−PW
Addressable 135° Fixed Temp. Thermal Sensor w/ Base
ATD−L2F &
B210LP135F
AOM−TELFAddressable Telephone Monitor ModuleTELF
TBDSurge Suppressor ModuleSS
Addressable Monitor Module, Class B AMM−2FAMM2F
Network Graphic Annunciator NGANGA
Addressable Switch Module ASM−16ASM
Microphone INCC−MICMIC
Digital Alarm Communicator / Transmitter DACT−E3DACT
AOM2SF
M111L1
AOM2SF
M105L1
AOM2SF
M112L1
AOM2SF
M115L1
AOM2SFM116L1
AOM2SF
M114L1
AOM2SF
M100L1
AOM2SF
M108L1
AOM2SF
M106L1
FS sprinkler riser TBD
NAC 1−4 M
NAC 1−3 M
NAC 1−3 M
NAC 1−4 M
NAC 1−4 M
NAC 1−4 M
NAC 1−4
M
NAC 1−3 M
NAC 1−3 M
NAC 1−3 M
NAC 1−3 M
NAC 1−4 M
NAC 4−3 M
NAC 4−3 M
NAC 4−3 M
NAC 2−4 M
NAC 2−4 M
NAC 2−4 M
NAC 2−3 M
NAC 2−3 M
NAC 2−3 M
NAC 4−4 M
NAC 4−4 M
NAC 4−4 M
NAC 4−4 M
NAC 4−3 M
NAC 4−3 M
NAC 4−3
M
NAC 3−3 M
NAC 1−3
M
NAC 4−3 M
NAC 3−4
M
NAC 3−3 M
NAC 3−3 M
SPK 2
M
SPK 2
MSPK 2
M
NAC 3−4 M
NAC 3−4 M
NAC 3−4 M
1 W
NAC 1−2
SPK 4−1
S
NAC 1−3 M
NAC 3−1
SPK 2−2
S
NAC 3−3 M
NAC 1−4 M
P1 pwr supv.
120 vac
AMM4F
M026L1
TS sprinkler riser
AMM4F
M025L1
FS sprinkler riser
SPK 3−2
M
RTS
AMM4F
M013L1
P1 pwr supv.
NAC 2−3 M
PS
#3
AMM4F
M021L1
NGA − Node 5 VGC − Node 6
NGA − Node 7 VGC − Node 8
NGA − Node 21 VGC − Node 22
NGA − Node 9 VGC − Node 10
1 W
NAC 4−1
SPK 1−2
S
NGA − Node 23 VGC − Node 24
1 W
NAC 4−1
SPK 1−2
S
NAC 4−3M
RTS
Breakers
PSAMM4F
M020L1
PS #
NA
C
FA
CP #
AMM2F
M017L1
AMM2F
M018L1
ILI−MB − Node 1 VGX − Node 2 ANX − Node 61
NGA − Node 11 VGC − Node 12
NGA − Node 13 VGC − Node 14
NGA − Node 15 VGC − Node 16
SPK 1−2
M
ILI−MB − Node 57 VGX − Node 58
L1S001 DT
S100L1
AOM2SF
M100L1
AMM4F
M001L1
NGA − Node 25 VGC − Node 26
PS
#4
AMM4F
M022L1
M
L
NAC 1−1
SPK 2−1S
M
L
NAC 3−3 M
NAC 3−1
SPK 2−2 S
L1S001
ILI−MB − Node 59 VGX − Node 60
#4
NAC 3−2
SPK 2−1S
NAC 3−4M
NAC 3−2
SPK 2−1 S
NAC 3−4 M
NAC 3−4 M
NAC 3−2
SPK 2−1 S
SPK 2−1
M
NAC 3−4 M
NAC 3−2
SPK 2−1 S
NAC 3−4 M
NAC 3−2
SPK 2−1SNAC 3−4 M
SPK 2−1
M
SPK 2−1
M
SPK 2−1
M
SPK 3−2
M
AMM2F
M019L1
AMM2F
M016L1
P1pwr supv
SPK 2−1
M
L1S106 L1S107
SPK 2−2
M
SPK 2−2
M
SPK 2−2
M
SPK 2−2
M
SPK 2−2
M
SPK 2−2
M
NGA − Node 17 VGC − Node 18
No Connections to Elevator Controls
SPK 2−2
M
SPK 2−2
M
SPK 2−2
M
SPK 2−2
M SPK 2−2
M
SPK 2−2
M
SPK 2−2
M
SPK 2−2
M
SPK 2−2
M
AOM2RF
L1M098 holders AC door
SPK 4−1
MNAC 1−4 M
NAC 1−4 M
NAC 1−2
SPK 4−1
S
NAC 1−2
SPK 4−1
S
SPK 4−1
M
NGA − Node 19 VGC − Node 20
NAC 1−3 M
P1
RTS
A
A
−A ug
N ot if ic a ti on
C ir cu it C ha ng es
−J ul
R ec or d
D ra w in gs A s−
B ui lt s)
R ec or d
D ra w in gs A s−
B ui lt
s) w
N ot a ti on s
−J a n−
’1
R ec or d
D ra w in gs A s−
B ui lt
s) U pd a te d
−J un
1/2 W
NAC 3−2
SPK 2−1
S
M a tc hl in e
T hi s
S he et
M a tc hl in e
T hi s
S he et
Syracuse, NY 13206 2201 Burnet Avenue
Fax 315−463−5006 Ph. 315−433−1234
Endicott, NY 13760 428 East Main Street
Ph. 607−722−3200 Fax 607−722−2124
Syracuse Time & Alarm Co., Inc.
"Our Concern Makes the Difference"
R
R
COMPANY FIELD ADVISOR
REVIEW TO SPECIFICATION
REQUIREMENTS:
Drawing Number: Revision:
Scale: (Sheet 24" x 36")
Project Number:
Date:
Approved By:
Checked By:
Drawn By:
WAR
MJS
MSR
12000032805
N.Y.S. LICENSE#
DATE
PLOTTED
R E V
IS
IO
N
N O
D A T E
A
B C D E F G H J http://www.syrtime.com
A B C D E F G H J
Sheet:
21−Jul−14 provided to Syracuse Time & Alarm Co., Inc. (STA) as an aid for the installation using documentation and specifications. These drawings were produced utilized in conjunction with the contract plans be an installation drawing by itself. It shall be This is a typical drawing and is not intended to functionality. All questions or concerns must be equipment, plans, scope of the system or STA assumes no responsibility for changes in or to equipment manufacturer.
submitted in writing to an STA representative
The information contained in this document is the information contained on them shall not be authorized personnel only. These drawings and property of STA and is intended solely for use by permission by an authorized STA official only.
distributed to others without prior written
26−Sep−2011
1/16" = 1’−0"
L1 S038
DH
DH
L1 S132 uf
L1 S035
L1 S034 uf
L1 S033
L1 S032
L1 S030
L1 S029
L1 S131 ra opening in front of
L1 S027
L1 S026L1 S025
L1 S024
L1 S023 L1 S022
L1 S021
L1 S020
L1 S018
L1 S017
L1 S016
L1 S015
L1 S014
L1 S013
L1 S012
L1 S011
L1 S010 L1 S009
L1 S008
L1 S007
FS
FS
TSAMM4F
M003L1
AMM4F
M002L1
AMM4F
M001L1
DH
DH
DH
DH
L1 S006
DH
DH
DH
DH
DH
DH
DH
DH
L1 S037
#13 LOC
#14
LOC
LO
C
#16
LOC
LO
C
LO
C
#22LOC
LO
C
LO
C
#23
LOC
#21
LOC
DT
S113L1
DT
S111L1
DT
S110L1
DT
S109L1
DT
S108L1
DT
S107L1
DT
S118L1N1
DT
S119L1N1
DT
S104L1N1
DT
S102L1
DT
S101L1
DT
S100L1
P1 supply
P1
RTS
P1
RTS
RTS
RTS
RTS
AOM2SF
M131L1
AOM2SF
M112L1
RTS
RTS
LO
C
R om e R es ea rc h L a b
B ui ld in g
R om e, N ew Y or k
F ir e
A la rm
M a ss
N ot if ic a ti on
S ec on d
F lo or
D5794
557930
NAC 7−4
M
M NAC 6−4
M NAC 6−4
L1 S042
SPK 6−2
M
SPK 6−2 M
SPK 6−2
M
SPK 5−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 5−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 6−2
M
SPK 5−2
M
SPK 5−2
M
SPK 6−2
M
SPK 5−2
M
SPK 5−2
M
SPK 6−1
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 5−2
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 5−1
M
SPK 6−1M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 6−1
M SPK 6−1
M
SPK 6−1
M
SPK 6−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 6−1
M
SPK 6−1
M
SPK 5−1
M
SPK 2−1
M
SPK 5−1
M
SPK 6−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
SPK 5−1
M
NAC
#7
1/2 W
NAC 6−1
SPK 6−2
S 1/2 W
NAC 6−1
SPK 6−2
S
1/2 W
NAC 6−1
SPK 6−2
S
NAC 6−3 M
1/2 W
NAC 6−1
SPK 6−2
S
NAC 6−1
SPK 6−2S
NAC 6−3M
1/2 W
NAC 6−1
SPK 6−2
S
NAC 6−3M
NAC 6−1
SPK 6−2SNAC 6−3 M NAC 6−3MNAC 6−1
SPK 5−2 S
NAC 6−4M
1/2 W
NAC 6−2
SPK 6−2
S
NAC 6−4M
1/2 W
NAC 6−2
SPK 6−2
S
NAC 6−4M
NAC 6−4M
1/2 W
NAC 6−2
SPK 6−2
S
NAC 6−2
SPK 6−2 S
NAC 6−1
SPK 5−2 S NAC 6−3M
NAC 6−1
SPK 5−2S
NAC 6−2
SPK 6−2S
NAC 7−1
SPK 6−1SNAC 7−3 M
NAC 7−1
SPK 6−1S
NAC 7−2
SPK 6−1 S
NAC 7−4
M
NAC 7−2
SPK 6−1SNAC 7−4 M
NAC 6−3M
NAC 6−1
SPK 5−2
S
NAC 6−3M NAC 6−3 M
NAC 6−1
SPK 5−2
S
NAC 6−1
SPK 5−2S
NAC 6−3
M
NAC 6−1
SPK 5−2
S
NAC 6−1
SPK 5−2
S
NAC 6−3M
NAC 6−1
SPK 5−2
S
NAC 6−2
SPK 5−2
S
1/2 W
NAC 6−2
SPK 5−2
S
NAC 6−4M
1/4 W
NAC 6−2
SPK 5−2
S
NAC 6−2
SPK 5−2 S NAC 6−4M
1/2 W
NAC 6−2
SPK 5−2
S
NAC 6−4M
NAC 6−2
SPK 5−2
S
M NAC 6−4
V NAC 6−2
NAC 5−1
SPK 5−2
S
NAC 5−1
SPK 5−2 S NAC 5−3MNAC 5−3M
NAC 5−1
SPK 5−1
S
NAC 5−3M
M NAC 7−4
V NAC 7−2
NAC 7−2
SPK 6−1
S
NAC 7−4M
NAC 7−2
SPK 6−1
S
NAC 5−3 M
NAC 5−1
SPK 5−1
S
NAC 7−2
SPK 6−1S
NAC 7−2
SPK 5−1SNAC 7−4 M
NAC 7−2
SPK 5−1 S NAC 7−4M
NAC 7−4 M
NAC 7−2
SPK 5−1
S
NAC 5−3M
NAC 5−1
SPK 5−1
S
NAC 5−1
SPK 5−1 S NAC 5−3M
NAC 7−2
SPK 5−1SNAC 7−4 M
M NAC 5−3
V NAC 5−1
1/2 W
NAC 5−1
SPK 5−1
S
M NAC 5−3
1/2 W
NAC 5−1
SPK 5−1
S
NAC 5−1
SPK 5−1 S NAC 5−3M
NAC 5−1
SPK 5−1 S NAC 5−3M
NAC 5−3 M
NAC 5−1
SPK 5−1
S
NAC 5−3
M
NAC 5−1
SPK 5−1
S
NAC 5−1
SPK 5−1SNAC 5−3 M
1/2 W
NAC 7−2
SPK 5−1
S
NAC 7−4M
1/2 W
NAC 7−2
SPK 5−1
S
NAC 7−4 M
NAC 5−3M
NAC 5−1
SPK 5−1
S
NAC 7−1
SPK 6−1SNAC 7−3 M
M NAC 5−3
1/2 W
NAC 5−2
SPK 5−1
S
M NAC 5−4
NAC 5−4M
NAC 5−2
SPK 5−1
S
NAC 5−4M
NAC 5−2
SPK 5−1
S
NAC 5−4M
NAC 5−2
SPK 5−1
S NAC 5−4M
NAC 5−2
SPK 5−1
S
NAC 5−4 M
NAC 5−2
SPK 5−1
S
NAC 5−2
SPK 5−1S
NAC 5−4
M
1/2 W
NAC 7−2
SPK 5−1
S
NAC 5−3
M
1/2 W
NAC 5−1
SPK 5−1
S
NAC 5−4M
NAC 5−2
SPK 5−1
S
NAC 3−4
M
1/2 W
NAC 3−2
SPK 2−1
S
NAC 3−4
M
1/2 W
NAC 3−2
SPK 2−1
S
NAC 5−1
SPK 5−1
S
NAC 5−1
SPK 5−2
S
NAC 6−2
SPK 6−2 S NAC 6−4M
NAC 6−2
SPK 6−2 S NAC 6−4M
NAC 6−2
SPK 6−2 S NAC 6−4M
V NAC 6−2
NAC 6−2
SPK 6−2
S
1/2 W
NAC 5−2
SPK 5−1
S
M NAC 5−4
1/2 W
NAC 5−2
SPK 5−1
S
M NAC 5−4
1/2 W
NAC 5−2
SPK 5−1
S
M NAC 5−4
1/2 W
NAC 5−2
SPK 5−1
S
M NAC 5−4
1/2 W
NAC 5−2
SPK 5−1
S
M NAC 5−4
1/2 W
NAC 5−2
SPK 5−1
S
M NAC 5−4
1/2 W
NAC 5−2
SPK 5−1
S
M NAC 5−4
1/2 W
NAC 5−2
SPK 5−1
S
M NAC 5−4
1/2 W
NAC 5−2
SPK 5−1
S
M NAC 5−4
SPK 6−1
M
P1P1
PAM−1
Remote Annunciator
NGA, ASM−16,
INCC−MIC
Addressable Output Relay Control Module AOM−2RF
E3Fire Alarm Control Panel
NAC Expander Panel HPFF12
AOM−2SFAddressable Output Relay Supervised Control Module
Magnetic Door Holder DHF−24120C
DNR w/
ASD−PL2FR
Addressable Photoelectric Smoke Sensor w/ Base
ASD−PL2F &
B210LP
Speaker Strobe (15 candela, 1/4 watt U.O.N.)
SPSR
Remote Test Station Test & Reset Switch w/ Alarm LED
RTS151
SYMBOL LIST
SYMBOL DESCRIPTION MODEL
Sprinkler System Tamper Switch By Others
Sprinkler System Flow Switch
Dry−Pipe Sprinkler System Pressure Switch By Others
Strobe, Ceiling Mounted (30 candela U.O.N.)
SCR
Speaker Strobe, Ceiling Mounted (30 candela, 1/4 watt U.O.N.)
SPSCR
Relay Module
Addressable Photoelectric Duct Smoke Detector w/ Remote Test Capability
Addressable Monitor Module, Class A AMM−4F
DT
AOM2RF
AOM2SF
AMM4F
TS
FS
P1
PS
FACP
LOC
NAC
S
V
S
DH
RTS
By Others
Mass Notification Speaker Strobe (15 candela, 1/4 watt U.O.N.)
SPR
Mass Notification Strobe with Amber Lens (15 candela U.O.N.)
SW−P
Mass Notification Strobe with Amber Lens Ceiling Mounted (30 candela U.O.N.)
SCW−P
Mass Notification Speaker Strobe, Ceiling Mounted (1/4 watt U.O.N.)
SPSCRM
M
M
M
Mass Notification Speaker Only, Ceiling Mounted (1/4 watt U.O.N.)
SPCWM
W Mass Notification Speaker Only, Weatherproof (1 watt U.O.N.)
SPSRK
Addressable Double−Action Manual Station MS−7AFF
Mass Notification Strobe with Amber Lens Weatherproof (110 candela U.O.N.)
SWK−PW
Addressable 135° Fixed Temp. Thermal Sensor w/ Base
ATD−L2F &
B210LP135F
AOM−TELFAddressable Telephone Monitor ModuleTELF
TBDSurge Suppressor ModuleSS
Addressable Monitor Module, Class B AMM−2FAMM2F
Network Graphic Annunciator NGANGA
Addressable Switch Module ASM−16ASM
Microphone INCC−MICMIC
Digital Alarm Communicator / Transmitter DACT−E3DACT
AOM2SF
M100L1
AOM2SF
M157N1L1
AOM2SF
M102N1L1
AOM2SFM113L1
AOM2SF
M109L1
AOM2SF M111L1
AOM2SF
M107L1
AOM2SF
M118N1L1
P1
P1 accu−f242−1
NAC 6−4 M
NAC 6−4 M
NAC 7−4 M
NAC 7−3 M
NAC 5−3 M
NAC 6−4 M
NAC 6−3 M
NAC 6−3 M
NAC 6−4 M
NAC 5−3 M
NAC 7−4 M
RTSRTS
P1
AMM4F
M013N1L1
NGA − Node 45 VGC − Node 46
NAC 7−2
SPK 6−1
S
NAC 7−4 M
NAC 7−1
SPK 6−1S
NAC 7−3
M
NAC 7−3
M
NAC 7−1
SPK 6−1S
NAC 7−1
SPK 6−1 S
135F
S043L1
NAC
#6
PS
#5
AMM2F
M004L1
AMM2F
M005L1
AMM2F
M006L1
FACP
#2
ILI−MB: Node 27 VGX: Node 28
DT
S112L1
RTS
NGA − Node 29 VGC − Node 30
NAC 5−3MNAC 5−1
SPK 5−2 S
1 W
NAC 5−1
SPK 5−1
S
NAC 5−3M
NAC
#5
PS
#9
AMM2F
M011L1
AMM2F
M010L1
AMM2F
M009L1
PS
#8
N27L1S031
P1
P1
RTS
NGA − Node 31 VGC − Node 32
NGA − Node 33 VGC − Node 34
#15
P1 release door latch
AOM2SF
M098N27L1
AOM2SF
M102N27L1
DT
S102L1
DT
S103L1
DT
S104L1
DT
S105L1
AOM2SF
M104N27L1
NGA − Node 39 VGC − Node 40
SPK 5−2
M
NGA − Node 37 VGC − Node 38
NGA − Node 35 VGC − Node 36
NAC 6−4MNAC 6−2
SPK 6−2 S
NGA − Node 41 VGC − Node 42
NGA − Node 49 VGC − Node 50
NGA − Node 43 VGC − Node 44
AMM2F pwr supv
M014L1
NAC 6−3 MNAC 6−3 M
NAC 6−3 M
NAC 6−3 M
NAC 6−1
SPK 6−2
S
NAC 6−3M
NAC 6−1
SPK 6−2
S
NGA − Node 51 VGC − Node 52
NGA − Node 47 VGC − Node 48
PS#7
AMM2F
M007L1
AMM2F
M008L1
PS #8
DT
S103L1N1
DT
S106L1
RTS
AOM2SF
M106L1
P1
AMM2F pwr supv
M013L1
Above C139
−A ug
N ot if ic a ti on
C ir cu it C ha ng es
−J ul
R ec or d
D ra w in gs A s−
B ui lt s)
R ec or d
D ra w in gs A s−
B ui lt
s) w
N ot a ti on s
−J a n−
’1
R ec or d
D ra w in gs A s−
B ui lt
s) U pd a te d
−J un
Syracuse, NY 13206 2201 Burnet Avenue
Fax 315−463−5006 Ph. 315−433−1234
Endicott, NY 13760 428 East Main Street
Ph. 607−722−3200 Fax 607−722−2124
Syracuse Time & Alarm Co., Inc.
"Our Concern Makes the Difference"
R
R
COMPANY FIELD ADVISOR
REVIEW TO SPECIFICATION
REQUIREMENTS:
Drawing Number: Revision:
Scale: (Sheet 24" x 36")
Project Number:
Date:
Approved By:
Checked By:
Drawn By:
WAR
MJS
MSR
12000032805
N.Y.S. LICENSE#
DATE
PLOTTED
R E V
IS
IO
N
N O
D A T E
A
B C D E F G H J http://www.syrtime.com
A B C D E F G H J
Sheet:
21−Jul−14 provided to Syracuse Time & Alarm Co., Inc. (STA) as an aid for the installation using documentation and specifications. These drawings were produced utilized in conjunction with the contract plans be an installation drawing by itself. It shall be This is a typical drawing and is not intended to functionality. All questions or concerns must be equipment, plans, scope of the system or STA assumes no responsibility for changes in or to equipment manufacturer.
submitted in writing to an STA representative
The information contained in this document is the information contained on them shall not be authorized personnel only. These drawings and property of STA and is intended solely for use by permission by an authorized STA official only.
distributed to others without prior written
26−Sep−2011
1/16" = 1’−0"
R om e R es ea rc h L a b
B ui ld in g
R om e, N ew Y or k
F ir e
A la rm
M a ss
N ot if ic a ti on
P en th ou se L ev el
DT
S123L1
DT
S130L1
DT
S129L1
DT
S128L1
DT
S127L1
DT
S125L1
DT
S124L1
DT
b2
S114L1
DT
p2
S122L1
DT
S121L1
DT
p1
S120L1
DT
p1
S119L1 DT
S118L1
DT
b2
S116L1
L1 S039
RTS
P1 ef−b2−1
P1ef−p1−2
P1 ahu−p1
P1 ahu−p2
RTS
RTSRTS
RTS
RTS
P1 ahu−a1
P1 ef−a1−1
RTS
RTS
RTS
RTS
LO
C
L1 S040 shaft top of
D5794
1/2 W
NAC 6−2
SPK 5−2S
1/2 W
NAC 7−1
SPK 6−2S
1/2 W
NAC 7−1
SPK 6−2S
NAC 6−4
M
1/2 W
NAC 6−2
SPK 5−2
S
NAC 7−3 M
P1 ahu−a2
PAM−1
Remote Annunciator
NGA, ASM−16,
INCC−MIC
Addressable Output Relay Control Module AOM−2RF
E3Fire Alarm Control Panel
NAC Expander Panel HPFF12
AOM−2SFAddressable Output Relay Supervised Control Module
Magnetic Door Holder DHF−24120C
DNR w/
ASD−PL2FR
Addressable Photoelectric Smoke Sensor w/ Base
ASD−PL2F &
B210LP
Speaker Strobe (15 candela, 1/4 watt U.O.N.)
SPSR
Remote Test Station Test & Reset Switch w/ Alarm LED
RTS151
SYMBOL LIST
SYMBOL DESCRIPTION MODEL
Sprinkler System Tamper Switch By Others
Sprinkler System Flow Switch
Dry−Pipe Sprinkler System Pressure Switch By Others
Strobe, Ceiling Mounted (30 candela U.O.N.)
SCR
Speaker Strobe, Ceiling Mounted (30 candela, 1/4 watt U.O.N.)
SPSCR
Relay Module
Addressable Photoelectric Duct Smoke Detector w/ Remote Test Capability
Addressable Monitor Module, Class A AMM−4F
DT
AOM2RF
AOM2SF
AMM4F
TS
FS
P1
PS
FACP
LOC
NAC
S
V
S
DH
RTS
By Others
Mass Notification Speaker Strobe (15 candela, 1/4 watt U.O.N.)
SPR
Mass Notification Strobe with Amber Lens (15 candela U.O.N.)
SW−P
Mass Notification Strobe with Amber Lens Ceiling Mounted (30 candela U.O.N.)
SCW−P
Mass Notification Speaker Strobe, Ceiling Mounted (1/4 watt U.O.N.)
SPSCRM
M
M
M
Mass Notification Speaker Only, Ceiling Mounted (1/4 watt U.O.N.)
SPCWM
W Mass Notification Speaker Only, Weatherproof (1 watt U.O.N.)
SPSRK
Addressable Double−Action Manual Station MS−7AFF
Mass Notification Strobe with Amber Lens Weatherproof (110 candela U.O.N.)
SWK−PW
Addressable 135° Fixed Temp. Thermal Sensor w/ Base
ATD−L2F &
B210LP135F
AOM−TELFAddressable Telephone Monitor ModuleTELF
TBDSurge Suppressor ModuleSS
Addressable Monitor Module, Class B AMM−2FAMM2F
Network Graphic Annunciator NGANGA
Addressable Switch Module ASM−16ASM
Microphone INCC−MICMIC
Digital Alarm Communicator / Transmitter DACT−E3DACT
AOM2SF
M124L1
AOM2SF
M139L1
AOM2SF
M126L1
P1 ahu−b2AOM2SF M115L1
P1 ef−p1−1AOM2SF M114L1
P1 ahu−b1AOM2SF M117L1
AOM2SF
M122L1
AOM2SF
M120L1
AOM2SF
M119L1
AOM2SF
M116L1
NAC 7−3 M
NAC 6−4 M
GWF−506RPre−Action Control Panel (Releasing)PACP
Pre−Action System Symbols
SYMBOL DESCRIPTION MODEL
Conventional Smoke Detector w/ Base 2151 & B110LP
Suppression System Manual Station MS−2SF S
Horn Strobe (15/75 candela, Temporal Output U.O.N.)
P2RF
RTS P1
ahu−a2
AOM2SF
M129L1
RTSRTS RTS
NGA − Node 53 VGC − Node 54
P1 ahu−a1
AOM2SF
M125L1
DT
S126L1
AOM2SF
M121L1
P1 ahu−p1
DT
p1
S117L1
DT
b2
S115L1
RTS
P1 ef−b1−1AOM2SF
M118L1
LO
C
VGC − Node 56 NGA − Node 55
1/2 W
NAC 6−1
SPK 5−2S110
NAC 6−3 M
1/2 W
NAC 6−2
SPK 5−2
S110
NAC 6−4 M
1/2 W
NAC 6−2
SPK 5−2S110
NAC 6−4 M
−A ug
N ot if ic a ti on
C ir cu it C ha ng es
−J ul
R ec or d
D ra w in gs A s−
B ui lt s)
R ec or d
D ra w in gs A s−
B ui lt
s) w
N ot a ti on s
−J a n−
’1
R ec or d
D ra w in gs A s−
B ui lt
s) U pd a te d
−J un
Fax 315−463−5006 Ph. 315−433−1234
Endicott, NY 13760 428 East Main Street
Ph. 607−722−3200 Fax 607−722−2124
Syracuse Time & Alarm Co., Inc.
"Our Concern Makes the Difference"
R
R
COMPANY FIELD ADVISOR
REVIEW TO SPECIFICATION
REQUIREMENTS:
Drawing Number: Revision:
Scale: (Sheet 24" x 36")
Project Number:
Date:
Approved By:
Checked By:
Drawn By:
WAR
MJS
MSR
12000032805
N.Y.S. LICENSE#
DATE
PLOTTED
R E V
IS
IO
N
N O
D A T E
A
B C D E F G H J http://www.syrtime.com
A B C D E F G H J
Sheet:
21−Jul−14 provided to Syracuse Time & Alarm Co., Inc. (STA) as an aid for the installation using documentation and specifications. These drawings were produced utilized in conjunction with the contract plans be an installation drawing by itself. It shall be This is a typical drawing and is not intended to functionality. All questions or concerns must be equipment, plans, scope of the system or STA assumes no responsibility for changes in or to equipment manufacturer.
submitted in writing to an STA representative
The information contained in this document is the information contained on them shall not be authorized personnel only. These drawings and property of STA and is intended solely for use by permission by an authorized STA official only.
distributed to others without prior written
26−Sep−2011
1/16" = 1’−0"
R om e R es ea rc h L a b
B ui ld in g
R om e, N ew Y or k
F ir e
A la rm
M a ss
N ot if ic a ti on
R is er
D ia gr a m
E3 FACP #1
LCD−E3
Mounted at Electric D150
SPK
1−1
NAC
RTU
Radio / IP
Transmitter
SPK
1−2
COAX BY STA
(100’ MAX.)
ANTENNA
TELFLine Audio
120VAC
C
NAC
RT
Battery Cabinet with 2 x 55Ah Batteries
12/2
NET
SLC
24V
D (Typ.)
B
Mounted adjacent to FACP
A
AOM2SF
P1
F SLC Return to FACP Class ’A’ Module
A (Typ.)
FLOOR
CEILING
8"
T O C
E N T E R
T O B
O T T O M O
F L
E N S
PULL STATION
NOTIFICATION
APPLIANCE IN
PUBLIC SPACE
T O T
O P O
F P
A N E L S
A N D A
N N U N C
IA
T O R S
SMOKE OR THERMAL DETECTOR
J-BOX
Equipment Mounting Heights SCALE: No Scale
To LOC #15 (2nd Floor)
AOM2SF
DH DH
E
NET
FACP
#1
LOC
#5
LOC
#6
LOC
#7
LOC
#12
LOC
#8
LOC
#9
LOC
#10
LOC
#1
LOC
#2
LOC
#3
LOC
#4
LOC
#11
LOC
#21
LOC
#23
LOC
#19
LOC
#22
LOC
#24
LOC
#20
LOC
#16
LOC
#17
LOC
#25
LOC
#18
LOC
#14
LOC
#15
LOC
#26
AOM2RF
P1
P1
AOM2RF
LOC
#13
D5794
NAC
NAC
NAC
NAC
B (Typ.)B (Typ.)
NAC Return to HPFF12 Class ’A’ Module
V
V
NAC Return to HPFF12 Class ’A’ Module
S
S
S S
S
NAC
NAC
B (Typ.)
S
S
S
NAC
NAC
NAC
NAC
B (Typ.)
NAC
NAC
NAC
NAC
B (Typ.)
NAC
NAC Return to HPFF12 Class ’A’ Module
NAC Return to HPFF12 Class ’A’ Module
Return to FACP #1
B (Typ.)
M
Speaker Return to FACP
C
Mounted @ Room D150
M W W
Speaker Return to FACP
C (Typ.)
B (Typ.)
NAC Return to HPFF12 Class ’A’ Module
NAC
NAC Return to HPFF12 Class ’A’ Module
M MM M
NAC Return to HPFF12 Class ’A’ Module
NAC
M MM M
NAC Return to HPFF12 Class ’A’ Module
M MM M
M MM M
C
B (Typ.)
NAC Return to HPFF12 Class ’A’ Module
V
V
NAC Return to HPFF12 Class ’A’ Module
S S
S
S S
S
NAC Return to HPFF12 Class ’A’ Module
NAC Return to HPFF12 Class ’A’ Module
B (Typ.)
NAC Return to HPFF12 Class ’A’ Module
NAC Return to HPFF12 Class ’A’ Module
M MM M
NAC Return to HPFF12 Class ’A’ Module
M MM M
NAC Return to HPFF12 Class ’A’ Module
M MM M
M MM M
Speaker Return to FACP
C
B (Typ.)
Mass Notification
Fire Alarm
Fire Alarm
Fire Alarm
Fire Alarm
Mass Notification
Mass Notification
Fire Alarm
B
Input #2
Input #1
SPK
2−1
SPK
2−2
SLC
Door Holder Power
B
PS
#1
AMM4F
B
B,D B,D D
PS
#4
AMM4F
B
B,D B,D D
PS
#3
AMM4F
B
B,D B,D D
PS
#2
AMM4F
B
B,D B,D D
Input #2
Input
#1HPFF12 NAC
Booster Panel #4
Input #2
Input #1
Input #2
Input #1
FS
AMM4F
FS
AMM4F
DT
RTS
DT
RTS
135F 135F
AOM2SF AOM2SF
Elevator Controls
P1P1
Fan Shutdowns
E3 FACP #2
LCD−E3
Mounted at Room E220
Battery Cabinet with 2 x 55Ah Batteries
12/2
NET
SLC
24V
FACP
#2
SLC
D (Typ.)
SPK
5−1
NAC
SPK
5−2
NAC
B
NAC
NAC
NAC
NAC
B (Typ.)B (Typ.)
NAC Return to HPFF12 Class ’A’ Module
V
V
NAC Return to HPFF12 Class ’A’ Module
S
S
NAC Return to HPFF12 Class ’A’ Module
NAC Return to HPFF12 Class ’A’ Module
Mounted @ Rm C239
M MM M
M MM M
Mass Notification
Fire Alarm
SPK
6−1
SPK
6−2
Input #2
Input #1
M
Speaker Return to FACP
C
M W W
NAC
NAC
NAC
NAC
B (Typ.)
C (Typ.)
S
S
B (Typ.)
NAC Return to HPFF12 Class ’A’ Module
NAC Return to HPFF12 Class ’A’ Module
M MM M
NAC Return to HPFF12 Class ’A’ Module
M MM M
NAC Return to HPFF12 Class ’A’ Module
Fire Alarm
Fire Alarm
Mass Notification
Input #2
Input #1
NAC
NAC
NAC
NAC
B (Typ.)
S
S
B (Typ.)
NAC Return to HPFF12 Class ’A’ Module
NAC Return to HPFF12 Class ’A’ Module
M MM M
NAC Return to HPFF12 Class ’A’ Module
M MM M
NAC Return to HPFF12 Class ’A’ Module
Input #2
Input #1
120VAC
AOM2SF
P1
Fan Shutdowns
P1
DH DH
Door Holder Power
A
B
FS
AMM4F
FS
AMM4F
TS
AMM4F
TS
AMM4F
PS
AMM4F SLC Return to FACP Class ’A’ Module
A (Typ.)
DT
RTS
DT
RTS
120VAC
NAC Return to FACP #2
NAC Return to FACP #2 Mass
Notification
Fire Alarm
B
PS
#5
AMM4F
B
PS
#7
AMM4F
B
PS
#9
AMM4F
B
PS
#5
AMM4F
B
PS
#8
AMM4F
B
B
NET
B,D D D B,D D D D B,D D
DD
B,D
C
C
C (Typ.)
C (Typ.)C (Typ.)
120VAC
120VAC 120VAC
120VAC
120VAC
120VAC
E3 FACP #3
Mounted at Room C139
FACP
#3
120VAC
SPK
SPK
NAC
NAC
1 S
Speaker Return to FACP
C
FA Return to FACP
MM
Speaker Return to FACP
C
24V
SLC
SLC
NET
From Network of LOC #26
LOC
#26
D
To FACP #2
NET
E3 FACP #4
Mounted at Rm C147
FACP
#4
120VAC
SPK
SPK
NAC
NAC
1 S
Speaker Return to FACP
M B
Speaker Return to FACP
C
24V
SLC
SLC
NET
NET
Network Return to FACP #1
E
C
S pa re S pa re
S pa reE B
C
E
From Network of FACP #1
LOC Annunciator Layout SCALE: No Scale
General Fire Alarm Notes
1) No conduits allowed into bottom of fire alarm cabinets.
2) Riser diagram is for general wiring purposes only.
3) T−Tapping of IDCs is permitted.
4) T−Tapping of NACs is permitted.
6) Wiring must be in accordance with Article 760, NFPA 70, and state & local codes.
7) Separate earth ground required. Cold waterpipe or approved equal.
8) Do use PAM−1 relays to directly control fan motors.
5) T−Tapping of SLCs is permitted.
PAM−1
Remote Annunciator
NGA, ASM−16,
INCC−MIC
Addressable Output Relay Control Module AOM−2RF
E3Fire Alarm Control Panel
NAC Expander Panel HPFF12
AOM−2SFAddressable Output Relay Supervised Control Module
Magnetic Door Holder DHF−24120C
DNR w/
ASD−PL2FR
Addressable Photoelectric Smoke Sensor w/ Base
ASD−PL2F &
B210LP
Speaker Strobe (15 candela, 1/4 watt U.O.N.)
SPSR
Remote Test Station Test & Reset Switch w/ Alarm LED
RTS151
SYMBOL LIST
Sprinkler System Tamper Switch By Others
Sprinkler System Flow Switch
Dry−Pipe Sprinkler System Pressure Switch By Others
Strobe, Ceiling Mounted (30 candela U.O.N.)
SCR
Speaker Strobe, Ceiling Mounted (30 candela, 1/4 watt U.O.N.)
SPSCR
Relay Module
Addressable Photoelectric Duct Smoke Detector w/ Remote Test Capability
Addressable Monitor Module, Class A AMM−4F
DT
AOM2RF
AOM2SF
AMM4F
TS
FS
P1
PS
FACP
LOC
NAC
S
V
S
DH
RTS
By Others
Mass Notification Speaker Strobe (15 candela, 1/4 watt U.O.N.)
SPR
Mass Notification Strobe with Amber Lens (15 candela U.O.N.)
SW−P
Mass Notification Strobe with Amber Lens Ceiling Mounted (30 candela U.O.N.)
SCW−P
Mass Notification Speaker Strobe, Ceiling Mounted (1/4 watt U.O.N.)
SPSCRM
M
M
M
Mass Notification Speaker Only, Ceiling Mounted (1/4 watt U.O.N.)
SPCWM
W Mass Notification Speaker Only, Weatherproof (1 watt U.O.N.)
SPSRK
Addressable Double−Action Manual Station MS−7AFF
Mass Notification Strobe with Amber Lens Weatherproof (110 candela U.O.N.)
SWK−PW
Addressable 135° Fixed Temp. Thermal Sensor w/ Base
ATD−L2F &
B210LP135F
AOM−TELFAddressable Telephone Monitor ModuleTELF
E120Surge Suppressor ModuleSS
Addressable Monitor Module, Class B AMM−2FAMM2F
Network Graphic Annunciator NGANGA
Addressable Switch Module ASM−16ASM
Microphone INCC−MICMIC
Digital Alarm Communicator / Transmitter DACT−E3DACT
SS
SS
SS
SSSS
AOM2SF
P1
Battery Cabinet w/ 2 x 33AH Batteries
NGA: Node 7 VGC: Node 8
NGA: Node 9 VGC: Node 10
NGA: Node 23 VGC: Node 24
NGA: Node 11 VGC: Node 12
NGA: Node 13 VGC: Node 14
NGA: Node 15 VGC: Node 16
NGA: Node 25 VGC: Node 26
NGA: Node 17 VGC: Node 18
NGA: Node 19 VGC: Node 20
NGA: Node 21 VGC: Node 22
NGA: Node 3 VGC: Node 4
NGA: Node 5 VGC: Node 6
Battery Cabinet w/ 2 x 33AH Batteries
Battery Cabinet w/ 2 x 33AH Batteries
Battery Cabinet w/ 2 x 33AH Batteries
NGAASM−16MIC
NGAMIC ASM
ASM−16
ASM
ILI: Node 1 VGX: Node 2
Battery Cabinet w/ 2 x 33AH Batteries
Battery Cabinet w/ 2 x 33AH Batteries
Battery Cabinet w/ 2 x 33AH Batteries
Battery Cabinet w/ 2 x 33AH Batteries
NGA: Node 45 VGC: Node 46
ILI: Node 27 VGX: Node 28
NGA: Node 49 VGC: Node 50
NGA: Node 41 VGC: Node 42
NGA: Node 47 VGC: Node 48
NGA: Node 51 VGC: Node 52
NGA: Node 43 VGC: Node 44
NGA: Node 35 VGC: Node 36
NGA: Node 37 VGC: Node 38
NGA: Node 53 VGC: Node 54
NGA: Node 39 VGC: Node 40
NGA: Node 31 VGC: Node 32
NGA: Node 33 VGC: Node 34
NGA: Node 29 VGC: Node 30
NGA: Node 55 VGC: Node 56
ILI: Node 57 VGX: Node 58
ILI: Node 59 VGX: Node 60
120VAC 120VAC 120VAC 120VAC
120VAC 120VAC 120VAC 120VAC
120VAC
AM−50
Amplifier
AM−50
Amplifier
16 / 2 FPLR, Unshielded, Twisted West Penn 990
CABLE LEGEND
SYMBOL DESCRIPTION MODEL
A
12 / 2 FPLR, Unshielded, Twisted West Penn 998B
16 / 2 FPLR, Shielded, Twisted West Penn 991C
NOTE:
of that type of cable to be used. No preceding number indicates that one (1)
The number preceding the designated cable type indicates the quantity of the quantity of that cable indicated is to be used.
16 / 2 FPLR, Unshielded, Twisted West Penn D990D
E 62.5/125 Micron Multi−Mode Fiber Pair To Be Determined
GWF−506RPre−Action Control Panel (Releasing)PACP
Pre−Action System Symbols
SYMBOL DESCRIPTION MODEL
Conventional Smoke Detector w/ Base 2151 & B110LP
Suppression System Manual Station MS−2SF S
Horn Strobe (15/75 candela, Temporal Output U.O.N.)
P2RF
AM−50
Amplifier
AM−50
Amplifier
AM−50
Amplifier
AM−50
Amplifier
M
B
B
B C
1.7 Amps
2.2 Amps
1.6 Amps
2.2 Amps
1.3 Amps
2.0 Amps
1.3 Amps
2.4 Amps
1.4 Amps
1.5 Amps
1.5 Amps
1.5 Amps
1.7 Amps
1.6 Amps
1.7 Amps
1.9 Amps
0.8 Amps
1.1 Amps
0.8 Amps
1.1 Amps
1.5 Amps
1.5 Amps
1.5 Amps
1.5 Amps1.7 Amps
1.4 Amps
1.4 Amps
1.1 Amps
SPK
3−1
SPK
3−2
Spare
SPK
4−1
SPK
4−2
.5
W a tt s
.7
W a tt s
.7
W a tt s
.5
W a tt s
.7
W a tt s
.0
W a tt s
.2
W a tt s
.5
W a tt s
.7
W a tt s
.7
W a tt s
C (Typ.)
S S
S
Speaker Return to FACP
SS
S
S S
S
S S
SS S
S
S
S
S
S
S
SS
Speaker Return to FACP #2
M
Speaker Return to FACP
C
M W W
M
Speaker Return to FACP
C
M W W
C (Typ.)
M
Speaker Return to FACP
M W W
M
Speaker Return to FACP
M W W
C
C Speaker Return to FACP
C
B (Typ.)
V
V
C (Typ.)
Speaker Return to FACP
V
C
V
V
NAC
HPFF12 NAC
Booster Panel #3
NAC
HPFF12 NAC
Booster Panel #2
NAC
HPFF12 NAC
Booster Panel #1
NAC
HPFF12 NAC
Booster Panel #7
NAC
HPFF12 NAC
Booster Panel #6
NAC
HPFF12 NAC
Booster Panel #5
.0
W a tt s
.7
W a tt s
AMM4F
INI−VGX NET
Network to
FACP #3
Network from
FACP #4
NET
D
Network from
LOC #14
INI−VGX
RPT−E3
D
D150 C128
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
B105 F152
Mounted at Room C128
Mounted at Room C128
M
B
B
MNS Return to FACP
B
B
FA Return to FACP
MNS Return to FACP
DT
AOM2SF
P1
Mounted @ Room D150
RT
B A
INI−VGX
SLC
RPT−E3
AMM2F
AMM2F AMM2F
AMM2F
RTS
Return to FACP #1
AMM2F
AMM2FAMM2F
C (Typ.)
Mounted at Room E220
Mounted at Room E220
E220 C239
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
NGAASM−16MIC
NGAMIC ASM
C239
B
To FACP #1
From LOC #11
D
PS
#9
AMM4F
B
PS
#6
AMM4F
B
120VAC120VAC
PS
#9
AMM4F
B
120VAC
PS
#6
AMM4F
B
Battery Cabinet w/ 2 x 33AH Batteries
120VAC
PS
#6
AMM4F
B
120VAC
Mech. Rm.
near Auditorium
Mech. Rm.
near Auditorium
Mech. Rm.
near Auditorium
Mech. Rm.
near Auditorium
C239
C239 E220
POWER
ON
ALARM
SUPERVISORY
SYSTEM
TROUBLE
FAULT
GROUND
19.25"
−A ug
N ot if ic a ti on
C ir cu it C ha ng es
−J ul
R ec or d
D ra w in gs A s−
B ui lt s)
R ec or d
D ra w in gs A s−
B ui lt
s) w
N ot a ti on s
−J a n−
’1
R ec or d
D ra w in gs A s−
B ui lt
s) U pd a te d
−J un
Fax 315−463−5006 Ph. 315−433−1234
Endicott, NY 13760 428 East Main Street
Ph. 607−722−3200 Fax 607−722−2124
Syracuse Time & Alarm Co., Inc.
"Our Concern Makes the Difference"
R
R
COMPANY FIELD ADVISOR
REVIEW TO SPECIFICATION
REQUIREMENTS:
Drawing Number: Revision:
Scale: (Sheet 24" x 36")
Project Number:
Date:
Approved By:
Checked By:
Drawn By:
WAR
MJS
MSR
12000032805
N.Y.S. LICENSE#
DATE
PLOTTED
R E V
IS
IO
N
N O
D A T E
A
B C D E F G H J http://www.syrtime.com
A B C D E F G H J
Sheet:
21−Jul−14 provided to Syracuse Time & Alarm Co., Inc. (STA) as an aid for the installation using documentation and specifications. These drawings were produced utilized in conjunction with the contract plans be an installation drawing by itself. It shall be This is a typical drawing and is not intended to functionality. All questions or concerns must be equipment, plans, scope of the system or STA assumes no responsibility for changes in or to equipment manufacturer.
submitted in writing to an STA representative
The information contained in this document is the information contained on them shall not be authorized personnel only. These drawings and property of STA and is intended solely for use by permission by an authorized STA official only.
distributed to others without prior written
26−Sep−2011
1/16" = 1’−0"
R om e R es ea rc h L a b
B ui ld in g
R om e, N ew Y or k
F ir e
A la rm
M a ss
N ot if ic a ti on
D et a il s
D5794
2 3
U L L
IS
T E D
C O M P A T
IB
L E
C O N T R O L P
A N E L
B210LP Detector Base
SCALE: NTS
MODELS:
● All ASD models filtrex
● All ATD models
GENERAL NOTES:
● Set address(es) as shown on plans.
● Do use looped wire under terminals 1 & 2.
● Break wire run to provide supervision of connections.
B210LP
Base
B210LP
Base
Back of the MS−7AF
1 2 3 4
From the FACP or Previous Device
To Next Device or Return to
FACP
Inside the MS−7AF
LOOP
ADDRESS
NO
RM
AL
ACTIVATED
LED
MS−7AF Double−Action Manual Station
SCALE: NTS
6 7 8 9
ONES
6 7 8 9
TENS
COMM.
LINE (+)
First Detector in Loop
Last Detector in Loop
COMM.
LINE (−)
UL / FM Listed Control Panel
COMM.
LINE
System Wiring Diagram for DNR
Wiring Diagram from DNR to RTS151 w/ Remote Test Capable Detector Head
TEST COIL +
TEST COIL −
COMM +
OUT +
COMM −
RA / RTS −
RA +
RTS +
Jumper
DNR Duct Smoke Detector Detail
SCALE: NTS
SCALE: NTS
Addressable SLC from FACP or Previous Device
AOM−2RF
AOM−2RF Relay Control Module Controlling 24VDC Door Holder Circuits
SCALE: NTS
Addressable SLC to Next Device or Return to FACP
N.C.
N.O.
COM
N.C.
COM
N.O.
24VDC
DOOR
HOLDER
DOOR
HOLDER
24VDC
PAM−1
WHITE
BLACK
RED
YELLOW (NC)
BLUE (COM)
ORANGE (NO)
PWR. SUPV.
RELAY
NOTE: PAM−1 relay wired to AOM EOL resistor for monitoring power circuit integrity.
PAM−1 WHITE
BLACK
RED
YELLOW (NC)
BLUE (COM)
ORANGE (NO)
WHITE
BLACK
RED
YELLOW (NC)
BLUE (COM)
ORANGE (NO)
WHITE
BLACK
RED
YELLOW (NC)
BLUE (COM)
ORANGE (NO)
47K
EOLR
T o
C on tr ol le d
D ev ic es o r
C ir cu it s
47K
EOLR
AMM−2F
VIOLET
YELLOW
R E D
B L A C K
PAM−1
PAM−1
MONITOR
MODULE
AOM−2SF
From 24VDC power supply.
Isolated, Regulated &
Power−Limited per NFPA70. (+)
AOM−2SF Supervised Control Module with Multiple Control Relays & AMM−2F for Power supervision
SCALE: NTS
Addressable SLC from FACP or Previous Device
22 μF Capacitor
Audio Input (1 volt peak−to−peak max)
Telephone System Interface (By TELCO Provider)
Isolated Audio to AOM−TEL
AOM−TEL
CNO
INI−VG Audio Riser from TB5−1 & TB5−2
SLC Loop from INI−VG
TB4−3 & TB4−4
AOM−TEL Mass Notification Interface Diagram
SCALE: NTS
22 μF Capacitor
AMM−2F
LOOP
ADDRESS
TENS ONES
SLC Loop from FACP or Previous
Device
SLC Loop to Next Device
Generic Terminal Block
Capacitors from 2 R−C (AOM−TEL) filters without the resistor.
NOTE: These are non−polarized capacitors.
3.9K Ω EOL
47K Ω
EOLR
SPEAKER
TO NEXT STROBE
OR EOLR
STROBE
FROM PREVIOUS
SPEAKER OR FACP(−)
FROM PREVIOUS
STROBE OR FACP(−)
SPECTRALERT SPEAKER/STROBE
INSTALLATION DIAGRAM
MODELS: ● All Models ● All Models
1W
2W
70V
25V
V O L T S
W A T T S
Adjust the slide switch on the rear of the device to the position for the desired candela setting. The candela setting is shown in the small window on the front of the device.
NOTE: SUPPLY POWER MUST BE CONTINUOUS FOR PROPER OPERATION.
TO NEXT SPEAKER
OR EOLR
To Next Device or Return to
FACP
To Next Device or Return to
FACP
Addressable SLC to Next Device or Return to FACP
AMM−4F Monitor Module
SCALE: NTS
Do use looped wire under terminals 1 & 2. break wire run to provide supervision of connections.
Do connect circuit wiring to the control unit or module, or apply power to any portion of the system until after the circuit test has been performed. All wiring must conform to all applicable codes, ordinances & regulations.
T0
T2
T4
T5
AMM−4F
T1T10
T8
T7
T6
T9
T3
T11
N or m a ll y O pe n D ev ic es
F or
C la ss B
C ir cu it .9
K E
O L R
Class "A" Return
Internal EOL at T8 & T9
Addressable SLC from FACP or Previous Device
Addressable SLC to Next Device or Return to FACP
SpectrALERT Strobe Installation Diagram
Input from FACP or Previous Device
Adjust the slide switch on the rear of the device to the position for the desired candela setting. The candela setting is shown in the small window on the front of the device.
Models: ● All models
Note: Supply Power must be continuous for proper operation.
Output to Next Device or EOLR
SpectrALERT ADVANCE Strobes
SCALE: NTS
SpectrALERT ADVANCE Speaker/Strobes
SCALE: NTS
J
4 + T
B
R S
R E L A Y D
R Y C
O N T A C T S
P W R S
U P I N T F
J
ARCNET ADDRESSSW2
1235 468 7
G N D
P W R
T R B L
S U P V
A L R M
D C
R S T
R X
T X
D U P
M R C
R E C
L E D
L E D
L E D
L E D
L E D
L E D
L E D
L E D
L E D
L E D
L E D
L E D
F L
TTB1
1 +
VD
C G N D
VD
C G N D
TB2
N A C
N A C
1 TB3
5A
85B
R B
G N D
A B
G N D
M U
M U
W5
AUX TERM
MB PR
W7
MB PR
W8
J T A G
J3
W1
J2 LOCAL ARCNET
BSEL0
BSEL1
W4
ARCNET
TERM
J4 ARCNET REPEATER
W9
GFLTJ5 LOCAL ARCNET
OFF ON OFF ON
W2
W3
DIS ENA
FACTORY
USE
1 2 3 4 5
T B
T B
T B
A
A
B B
1A
1A
1B
1B
.2
A
0V
F
S L O B
L O J
D3
D4
D2
E3 Cabinet (Internal View)
ILI−MB−E3
PM−9 (UNDER)
120VAC
AC POWER
ON
POWER
FAULT FAULT
GROUND ALARM SYSTEM
TROUBLE
SUPERVISORY SYSTEM
SILENCED
ALARM
ACKNOWLEDGE ACKNOWLEDGE
TROUBLE SIGNAL
SILENCE LAMP TEST
SYSTEM RESET/
MENU BACKSPACE/
EDIT
OK/
ENTER
−QZ ABC
2 3
DEF
GHI
4 5
JKL MNO
PRS
TUV
WXY
T1
6 7
L1
C12
C10
C15
C11
V out
G N D
V out
G N D
V out
G N D
JMP1
T B
T B
BATT+
BATT−
D A C T −E
R P T −E
−F
O I N S T A L L E D O
V E R I L I− M B −E
H
E R E
E3 Cabinet Door (Front View)
Node 55
Node 58
ILI−S−E3
Node 56
4 1
TB6
R S
S L C
S L C
TB4
P W R S
U P I N T F
J
ARCNET ADDRESSSW2
1235 468 7
G N D
P W R
T R B L
S U P V
A L R M
D C
R S T
R X
T X
D U P
M R C
R E C
L E D
L E D
L E D
L E D
L E D
L E D
L E D
L E D
L E D
L E D
L E D
L E D
F L
TTB1
1 +
VD
C G N D
VD
C G N D
J T A G
J3
W1
J2 LOCAL ARCNET
BSEL0
BSEL1
W4
ARCNET
TERM
J4 ARCNET REPEATER
W9
GFLT
J5 LOCAL ARCNET
OFF ON
W2
W3
DIS ENA
FACTORY
USE
1 2 3 4 5
ILI−S−E3
Node 57
ARCNET
J10
TB3
J3
J6
J5
J4
J8
J9
J7
J2 GFI
D18
PWR
D10
TX
RX1
D11
RX2
D12
TB2
TB4
RPT−E3.dwg
TB2
TB1
STANDBY
LED3 LED2 LED1
LINE2 LINE1
STATUS STATUS
K4
1"
19.375"
DACT−E3 RPT−E3−FO
(on main FACP only)
Typical FACP Enclosure Detail SCALE: No Scale
−A ug
N ot if ic a ti on
C ir cu it C ha ng es
−J ul
R ec or d
D ra w in gs A s−
B ui lt s)
R ec or d
D ra w in gs A s−
B ui lt
s) w
N ot a ti on s
−J a n−
’1
R ec or d
D ra w in gs A s−
B ui lt
s) U pd a te d
−J un
File details come from the government source that posted it. Updated .