Question and Answer Set 1_25RB003.pdf

PDF 341 KB Posted

Attached to
FA8604 Storage Aid System at Maxwell Air Force Base Alabama MMHS
Solicitation number
FA860425RB003
Issued by

About this file

This is a Question and Answer document (Set 1) for solicitation FA8604-25-R-B003 regarding modular cabinets at Maxwell AFB, AL, dated February 10, 2025. The Q&A clarifies specifications for Type A and Type B modular cabinets, primarily focusing on ESD (Electrostatic Discharge) requirements and cabinet dimensions.

The document addresses six questions covering cabinet specifications, notably clarifying that only one Type A cabinet requires an ESD rubber mat with minimum 1/16 inch thickness, while no ESD mats or fittings are required for other cabinets. It confirms that cabinets with 27" overall depth are acceptable if they meet the interior depth requirement of 25" +/-1". The Q&A also clarifies that ESD paint is not required for shelving, and no static dissipation connections are needed for any of the cabinets. This appears to be a technical clarification document that revises previous ESD requirements downward from what was originally specified in sections 3.1 and 3.2.2.9 of the original solicitation.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FA8604-25-R-B003

Maxwell AFB, AL Question & Answers Set 1 10 February 2025

Appendix C Modular Cabinets

1. 3.2.1 and 3.2.2.1 -

Type A and B Cabinets call for outside depth of 28” +/- ½” in 3.2.1 and an interior depth of 25” +/-1” in 3.2.2.1. If units are overall 27”D but the interior dimensions are in compliance with 3.2.2.1 is that acceptable.

Yes, this is acceptable.

2. 3.1 and 3.2.2.9 are in conflict per below. Please advise which is correct.

Only the ONE type A shall need an ESD rubber mat, no ESD mats or fittings are required for the rest of the modular cabinets.

3. 3.2.2.9 ESD Drawers -

Please elaborate on the requirements as there are numerous options available for ESD mats. Are you requesting only rubber mats or is the requirement for the mats to have attached devices to dissipate the static. Is there a required thickness for the rubber mats?

Only the ONE type A shall need an ESD rubber mat, no dissipation connections will be required. A minimum thickness of 1/16 inch will suffice. The rest of the modular cabinets will not require ESD mats or fittings.

FA8604-25-R-B003

Maxwell AFB, AL Question & Answers Set 1 10 February 2025

4. 3.1. states that one (1) Type A cabinet shall come equipped with proper ESD ttings.

Could you please clarify the specifics of what qualifies as "proper ESD fittings"?

Only the ONE type A shall need an ESD rubber mat and no additional ttings. A minimum thickness of 1/16 inch will suf ce.

5. 3.2.2.9 states Each drawer shall for both Type A and Type B shall ESD mats placed within. We can do this, but having ESD mats in the drawers will not serve any purpose if the rest of the cabinet is not prepped to handle ESD. Do you want ESD matting in all of the drawers for both Type A & B?

ESD matting and ttings are not needed in all the modular cabinets any longer, only the one type A will need the ESD rubber Mat.

Cover Purchase Description

6. 3.1.10 ESD Shelving - Does the ESD Shelving required to have ESD paint? Please elaborate on the requirements as there are numerous options available for ESD mats. Are you requesting only rubber mats or is the requirement for the mats to have attached devices to dissipate the static. Is there a required thickness for the rubber mats?

No ESD paint is required, only ESD rubber mats. Minimum thickness of 1/16 of an inch will suf ce and no connections to dissipation devices are needed.