This solicitation requests proposals for a material handling system at Jacksonville Air National Guard Base in Florida. The Air Force Materiel Command Lifecycle Management Center is seeking the design, fabrication, installation, and testing of conveyors and related equipment for outdoor storage building 1006 under a fixed-price contract. Proposals are due by July 11, 2022 and award will be made to the technically acceptable offeror with the lowest price. Evaluation will be based on lowest price technically acceptable. The acquisition is reserved entirely for small businesses with fewer than 500 employees. The contractor must register in the System for Award Management prior to award. All work must be completed within 300 days of award.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CANOPY-COVERED

ISU OUTDOOR STORAGE

B U

I L

D I N

G

GRAVITY ROLLER CONVEYOR

DEFLECTORS (TYP)

PALLET STOPS (TYP)

OPTION 3 - SEE COVER PD, TABLE 3.1

COLUMNS/FOOTERS

82' MIN

TOP VIEW

LUMBER DETAIL

REMOVABLE PALLET STOP

SIDE VIEW CROSS SECTION

STANDARD 10' CONVEYOR SECTION

SIDE VIEW

TOP VIEW WITHOUT ROLLERS

BACK-TO-BACK

TOP VIEW WITH ROLLERS

10'

6"

6"

30" 30" 30" 30"

3"

4"(MIN)

END VIEW

1"

1/2"

1"

4"(MIN)

5 3/4"(MIN)

4"

2x41x4 STACKED AND TRIMMED

(LUMBER OPTIONS)

1/4"(MIN)

ALL LUMBER TO BE SECURED

TO FRAME WITH CARRIAGE BOLTS

CONVEYOR

CONNECTION

HOLES

ANCHOR PLATES

STEEL ANGLE

SINGLE STEEL ANGLE WITH

CONVEYOR CONNECTION HOLES

ANCHOR PLATES

STEEL ANGLE

FRONT VIEW

SIDE VIEW

DEFLECTOR CONCEPT

OR RECESSED HEADS

FIXED PALLET STOP

SIDE VIEW END VIEW

4"

SLOTTED PLATE BOLTED

TO STEEL ANGLE

1/2"

ALL LUMBER SHALL BE HARDWOOD

112"

42"

(INSIDE OF GUIDE RAIL)

42"

1-1/2" (MIN)

1'-2"

4"

6"

ROLLER SECTION SPACING

GUIDE RAIL FLARE

117" MIN (INSIDE-TO-INSIDE)

112" (INSIDE-TO-INSIDE)

20" 20"

DEFLECTORS

(TYP)

LUMBER

(TYP)

REMOVEABLE

STOPS (TYP)

NOTES:

1. ROLLERS EXTEND A MINIMUM OF 1/4-INCH ABOVE ROLLER FRAME.

2. ALL ROLLERS ARE MINIMUM 2.5-INCH DIA. X 7 GA. STEEL.

3. ALL AXLES ARE MINIMUM 11/16-INCH HEX.

4. ALL STEEL ANGLE ANCHOR PLATES ARE MINIMUM 3-1/2-INCH X 3-INCH X

3/8-INCH ANGLE.

5. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING

CONDITIONS PRIOR TO STARTING WORK.

6. DETAILS/SECTIONS NOT TO SCALE.

G

H

F

E

D

C

B

A

H

G

F

E

D

C

B

A

2 3 4 5 6 7 8

MATERIAL HANDLING ENGINEERING SECTION

AFMC AFLCMC/EZPAE WPAFB OH

REV LTR BY DESCRIPTION DATE

AIR FORCE MATERIEL COMMAND

FILENAME DRAWING NO.

DATE

SCALE

SHEET OF

DRAFTSMAN

PROJECT ENGINEER

TITLE

REVIEWER

T

R

U

E

PLAN

JACKSONVILLE ANGB FL

125 LOGISTICS READINESS SQUADRON

SUPPLY WAREHOUSE

BUILDING 1006 - OUTSIDE STORAGE

GRAVITY ROLLER CONVEYORS OVERVIEW & DETAILS

EMMANUEL PAREL

EMMANUEL PAREL

MEGAN BLACKWELL

1 MARCH 2022

AS SHOWN N/A NJC109-04

1 1

AF Drawing NJC109-04 (rev 1) July 6, 2022

AF Drawing NJC109-04 (rev 1) July 6, 2022

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text N

AutoCAD SHX Text

USAF

AutoCAD SHX Text N

AutoCAD SHX Text E

Sheets and Views
AF DRAWING NJC109-04

File details come from the government source that posted it. Updated .