This solicitation requests proposals for a material handling system at Jacksonville Air National Guard Base in Florida. The Air Force Materiel Command Lifecycle Management Center is seeking the design, fabrication, installation, and testing of conveyors and related equipment for outdoor storage building 1006 under a fixed-price contract. Proposals are due by July 11, 2022 and award will be made to the technically acceptable offeror with the lowest price. Evaluation will be based on lowest price technically acceptable. The acquisition is reserved entirely for small businesses with fewer than 500 employees. The contractor must register in the System for Award Management prior to award. All work must be completed within 300 days of award.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CANOPY-COVERED
ISU OUTDOOR STORAGE
B U
I L
D I N
G
GRAVITY ROLLER CONVEYOR
DEFLECTORS (TYP)
PALLET STOPS (TYP)
OPTION 3 - SEE COVER PD, TABLE 3.1
COLUMNS/FOOTERS
82' MIN
TOP VIEW
LUMBER DETAIL
REMOVABLE PALLET STOP
SIDE VIEW CROSS SECTION
STANDARD 10' CONVEYOR SECTION
SIDE VIEW
TOP VIEW WITHOUT ROLLERS
BACK-TO-BACK
TOP VIEW WITH ROLLERS
10'
6"
6"
30" 30" 30" 30"
3"
4"(MIN)
END VIEW
1"
1/2"
1"
4"(MIN)
5 3/4"(MIN)
4"
2x41x4 STACKED AND TRIMMED
(LUMBER OPTIONS)
1/4"(MIN)
ALL LUMBER TO BE SECURED
TO FRAME WITH CARRIAGE BOLTS
CONVEYOR
CONNECTION
HOLES
ANCHOR PLATES
STEEL ANGLE
SINGLE STEEL ANGLE WITH
CONVEYOR CONNECTION HOLES
ANCHOR PLATES
STEEL ANGLE
FRONT VIEW
SIDE VIEW
DEFLECTOR CONCEPT
OR RECESSED HEADS
FIXED PALLET STOP
SIDE VIEW END VIEW
4"
SLOTTED PLATE BOLTED
TO STEEL ANGLE
1/2"
ALL LUMBER SHALL BE HARDWOOD
112"
42"
(INSIDE OF GUIDE RAIL)
42"
1-1/2" (MIN)
1'-2"
4"
6"
ROLLER SECTION SPACING
GUIDE RAIL FLARE
117" MIN (INSIDE-TO-INSIDE)
112" (INSIDE-TO-INSIDE)
20" 20"
DEFLECTORS
(TYP)
LUMBER
(TYP)
REMOVEABLE
STOPS (TYP)
NOTES:
1. ROLLERS EXTEND A MINIMUM OF 1/4-INCH ABOVE ROLLER FRAME.
2. ALL ROLLERS ARE MINIMUM 2.5-INCH DIA. X 7 GA. STEEL.
3. ALL AXLES ARE MINIMUM 11/16-INCH HEX.
4. ALL STEEL ANGLE ANCHOR PLATES ARE MINIMUM 3-1/2-INCH X 3-INCH X
3/8-INCH ANGLE.
5. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS PRIOR TO STARTING WORK.
6. DETAILS/SECTIONS NOT TO SCALE.
G
H
F
E
D
C
B
A
H
G
F
E
D
C
B
A
2 3 4 5 6 7 8
MATERIAL HANDLING ENGINEERING SECTION
AFMC AFLCMC/EZPAE WPAFB OH
REV LTR BY DESCRIPTION DATE
AIR FORCE MATERIEL COMMAND
FILENAME DRAWING NO.
DATE
SCALE
SHEET OF
DRAFTSMAN
PROJECT ENGINEER
TITLE
REVIEWER
T
R
U
E
PLAN
JACKSONVILLE ANGB FL
125 LOGISTICS READINESS SQUADRON
SUPPLY WAREHOUSE
BUILDING 1006 - OUTSIDE STORAGE
GRAVITY ROLLER CONVEYORS OVERVIEW & DETAILS
EMMANUEL PAREL
EMMANUEL PAREL
MEGAN BLACKWELL
1 MARCH 2022
AS SHOWN N/A NJC109-04
1 1
AF Drawing NJC109-04 (rev 1) July 6, 2022
AF Drawing NJC109-04 (rev 1) July 6, 2022
AutoCAD SHX Text S
AutoCAD SHX Text W
AutoCAD SHX Text N
AutoCAD SHX Text
USAF
AutoCAD SHX Text N
AutoCAD SHX Text E