The file's text, extracted by GovTribe without its formatting.
Attachment 5
FA8601-19-R-A011
BIDDING SCHEDULE
FOR OPTION YEAR 2
ON-CALL MAINTENANCE OF PAVEMENTS AND GROUNDS
WRIGHT PATTERSON AIR FORCE BASE, OHIO
PROJECT NUMBER: ZHTV181050
| Line NO. |
| ITEM |
| UOM |
| EST QTY |
| Unit Cost |
| Total |
| 2001AA |
| Replace Steel Handrails |
| LF |
| 125 |
| 2001AB |
| Provide Steel Handrails |
| LF |
| 125 |
| 2001AC |
| Provide Aluminum Handrails |
| LF |
| 125 |
| 2001AF |
| Replace Sign |
| EA |
| 25 |
| 2001AG |
| Replace Post |
| EA |
| 25 |
| 2001AH |
| Relocate Sign |
| EA |
| 25 |
| 2001AI |
| Relocate Post |
| EA |
| 25 |
| 2001AJ |
| Provide Sign |
| EA |
| 25 |
| 2002AJ |
| Provide New Monument/Sign complaint with UFC 3-120-01 Ch 3-1 |
| EA |
| 2 |
| 2001AK |
| Provide Post |
| EA |
| 25 |
| 2002AK |
| Provide Bollard |
| EA |
| 50 |
| 2003AK |
| Relocate or Replace Bollard |
| EA |
| 25 |
| 2001AL |
| Replace 3-Phase Vertical Induction Motor, 1/2-HP |
| EA |
| 13 |
| 2002AL |
| Provide Underground Ductbank for electrical system, Single Compartment |
| LF |
| 1000 |
| 2003AL |
| Provide Underground Ductbank for electrical system, Double Compartment |
| LF |
| 750 |
| 2001AM |
| Provide Traffic Signal Programming and Coding |
| HR |
| 30 |
| 2002AM |
| Provide Temporary Traffic Control During Construction, Heavy Traffic |
| Day |
| 40 |
| 2003AM |
| Provide Temporary Traffic Control During Construction, Light Traffic |
| Day |
| 300 |
| 2001AN |
| Replace Traffic Signal LED Light Ball |
| EA |
| 38 |
| 2001AO |
| Provide Pedestrian Signaling Head |
| EA |
| 5 |
| Line NO. |
| ITEM |
| UOM |
| EST QTY |
| Unit Cost |
| Total |
| 2001AP |
| Remove Traffic Signal |
| EA |
| 5 |
| 2002AP |
| Remove Traffic Signal System |
| INTXN |
| 1 |
| 2003AP |
| Provide Traffic Signal System |
| INTXN |
| 1 |
| 2001AQ |
| Provide Traffic Signal Loop Detector |
| EA |
| 10 |
| 2002AQ |
| Provide Traffic Counter System |
| EA |
| 1 |
| 2001AR |
| Relocate Street Light |
| EA |
| 5 |
| 02AR |
| Provide new Parking Light, |
| EA |
| 5 |
| 2003AR |
| Provide new Street Light |
| EA |
| 5 |
| 2001AS |
| Remove 30 Feet High Aluminum Street Light |
| EA |
| 5 |
| 2001AT |
| Remove 30 Feet Wood Pole |
| EA |
| 5 |
| 2001AU |
| Provide 2 Inch Polyvinyl Chloride Pipe (PVC) Schedule 40 |
| LF |
| 250 |
| 2001AV |
| Provide 4 Inch Polyvinyl Chloride Pipe (PVC) Schedule 40 |
| LF |
| 250 |
| 2001AW |
| Excavation |
| CY |
| 4250 |
| 2002AW |
| Provide Erosion Control |
| EA |
| 4 |
| 2001AX |
| Remove Pavement Rigid and Flexible |
| CY |
| 2500 |
| 2001AY |
| Remove Structural Concrete, Slabs, Walls and Footings |
| CY |
| 250 |
| 2001AZ |
| Remove Curb and Gutter |
| LF |
| 1250 |
| 2001BA |
| Remove Sidewalk |
| SF |
| 12500 |
| 2002BA |
| Remove Chain Link Fence |
| LF |
| 5000 |
| 2001BB |
| Remove Concrete Barrier Curb |
| LF |
| 500 |
| 2001BC |
| Remove Inlet |
| EA |
| 15 |
| 2001BD |
| Provide Select Fill |
| CY |
| 2500 |
| 2001BE |
| Re-Install Satisfactory Fill |
| CY |
| 1250 |
| 2001BF |
| Provide Rock Excavation |
| CY |
| 500 |
| 2001BG |
| Provide Cold Milling |
| SY |
| 25000 |
| 2002BG |
| Load and haul debris |
| Load |
| 4 |
| 2001BH |
| Provide Crack Sealing |
| LF |
| 500 |
| 2001BI |
| Provide concrete patching |
| CY |
| 63 |
| 2001BJ |
| Provide Compacted Aggregate ODOT-304 |
| TON |
| 9500 |
| 2001BK |
| Provide Bituminous Base Course ODOT-301 |
| TON |
| 625 |
| Line NO. |
| ITEM |
| UOM |
| EST QTY |
| Unit Cost |
| Total |
| 2001BL |
| Provide Tack Coat ODOT-407 |
| GAL |
| 7500 |
| 2001BM |
| Provide Prime Coat ODOT-408 |
| GAL |
| 2500 |
| 2001BN |
| Provide Coal Tar Seal |
| SY |
| 7500 |
| 2001BO |
| Provide Bituminous Rejuvenation |
| GAL |
| 7500 |
| 2001BP |
| Provide Single Bituminous Surface Treatment |
| SY |
| 12500 |
| 2001BQ |
| Provide Asphalt Concrete ODOT Item 448 Type I Binder Mix PG 64-22 |
| TON |
| 9250 |
| 2001BR |
| Provide Asphalt Concrete ODOT Item 448 Type II Binder Mix PG 64-22 |
| TON |
| 1875 |
| 2001BS |
| Provide Pothole Repair Hot Patch |
| SF |
| 25 |
| 2001BT |
| Provide Pothole Repair Cold Patch |
| SF |
| 25 |
| 2001BU |
| Remove Asphalt Concrete Curb |
| LF |
| 500 |
| 2001BV |
| Provide Paving Fabric |
| SY |
| 10000 |
| 2001BW |
| Provide Forms Reinforcing Steel and Concrete For Docks, Slabs, Walls, Ramps and Stairs |
| CY |
| 188 |
| 2001BX |
| Provide Non-Reinforced Concrete Pavement For Docks, Slabs, Walls, Ramps and Concrete Encased Conduits |
| CY |
| 188 |
| 2001BY |
| Provide Curb and Gutter |
| LF |
| 11250 |
| 2001BZ |
| Provide Concrete Barrier Curb |
| LF |
| 1750 |
| 2001CA |
| Provide Sidewalk |
| SF |
| 15000 |
| 2001CB |
| Provide Handicapped Curb and Sidewalk Ramp |
| EA |
| 50 |
| 2001CC |
| Remove Bumper Blocks |
| EA |
| 250 |
| 2001CD |
| Reset Bumper Blocks |
| EA |
| 250 |
| 2001CE |
| Provide Concrte Bumper Block |
| EA |
| 125 |
| 2001CF |
| Provide Concrete Block Pavement Include Edge Restraints |
| SF |
| 3750 |
| 2001CG |
| Provide Double Yellow Centerline |
| LF |
| 3750 |
| 2001CH |
| Provide 4 Inch Dash Yellow Line |
| LF |
| 8750 |
| 2001CI |
| Provide 4 Inch Dash White Line |
| LF |
| 2500 |
| 2001CJ |
| Provide 24 Inch Wide White Stop Bar |
| LF |
| 625 |
| 2001CK |
| Provide 4 Inch Solid White Line |
| LF |
| 27500 |
| 2001CL |
| Provide White Pavement Arrows |
| EA |
| 300 |
| 2001CM |
| Provide White Pavement Letters |
| EA |
| 300 |
| 2001CN |
| Provide 24 Inch Solid White Line For Crosswalk |
| LF |
| 250 |
| 2001CO |
| Provide 4 Inch Solid Yellow Line |
| LF |
| 5100 |
| Line NO. |
| ITEM |
| UOM |
| EST QTY |
| Unit Cost |
| Total |
| 2001CP |
| Replace Chain Link Fence, 4 Feet High |
| LF |
| 50 |
| 2001CQ |
| Replace Chain Link Fence, 6 Feet Hugh |
| LF |
| 50 |
| 2001CR |
| Replace Chain Link Fence, 7 Feet High |
| LF |
| 50 |
| 2001CS |
| Replace Chain Link Fence, 8 Feet High |
| LF |
| 6250 |
| 2001CT |
| Replace Chain Link Fence Gate, 4 Feet High |
| LF |
| 30 |
| 2001CU |
| Replace Chain Link Fence Gate, 6 Feet High |
| LF |
| 30 |
| 2001CV |
| Replace Chain Link fence Gate, 7 Feet High |
| LF |
| 50 |
| 2001CW |
| Replace Chain Link Fence Gate, 8 Feet High |
| LF |
| 250 |
| 2001CX |
| Provide Wood Fence, 8 Feet High |
| LF |
| 250 |
| 2001CY |
| Provide Steel Fence, 8 Feet High |
| LF |
| 125 |
| 2001CZ |
| Provide Chain Link Fence, 6 Feet High |
| LF |
| 125 |
| 2001DA |
| Provide Chain Link Fence, 7 Feet High |
| LF |
| 250 |
| 2001DB |
| Provide Chain Link Fence, 8 Feet High |
| LF |
| 125 |
| 2001DC |
| Provide Steel Fence Gate, 8 Feet High |
| LF |
| 60 |
| 2001DD |
| Provide Chain Link Fence Gate, 6 Feet High |
| LF |
| 60 |
| 2001DE |
| Provide Chain Link Fence Gate, 7 Feet High |
| LF |
| 150 |
| 2001DF |
| Provide Chain Link Fence Gate, 8 Feet High |
| LF |
| 60 |
| 2001DG |
| Remove Guardrail |
| LF |
| 125 |
| 2001DH |
| Provide Guardrail |
| LF |
| 125 |
| 2001DI |
| Provide 3/4 Inch Wire Rope 2 Runs of Cable Include Hardware |
| LF |
| 5000 |
| 2001DJ |
| Provide Deadman Anchor |
| EA |
| 25 |
| 2002DJ |
| Provide Tie Down & Pad for NMUSAF |
| EA |
| 1 |
| 2001DK |
| Provide Topsoil, Fertilizer, Seed and Mulch |
| SY |
| 8750 |
| 2001DL |
| Provide Topsoil, Fertilizer and Sod |
| SY |
| 2500 |
| 2001DM |
| Provide Tree Plantings 3 Inch Cal. B&B |
| EA |
| 125 |
| 2001DN |
| Remove Tree, Trunk Diameter 12 inch Includes Stump Chipping Down 18 inch |
| EA |
| 25 |
| 2001DO |
| Remove Tree, Trunk Diameter 24 Inch Includes Stump Chipping Down 18 inch |
| EA |
| 25 |
| 2001DP |
| Provide 8 Inch Water Pipe |
| LF |
| 125 |
| 2001DQ |
| Provide 8 Inch Water Gate Valve |
| EA |
| 3 |
| 2001DR |
| Provide Fire Hydrant With Valve |
| EA |
| 3 |
| Line NO. |
| ITEM |
| UOM |
| EST QTY |
| Unit Cost |
| Total |
| 2001DS |
| Relocate Fire Hydrant Includes New 6 Inch Diameter PVC Water Pipe C-900 and New Water Valve |
| EA |
| 5 |
| 2001DT |
| Relocate Post Indicator Valve Includes New 6 Inch Diameter PVC Water Pipe C-900 and New Water Valve |
| EA |
| 5 |
| 2001DU |
| Repair and Adjust Water Valve Box |
| EA |
| 25 |
| 2001DV |
| Provide 8 Inch Sanitary Pipe |
| LF |
| 250 |
| 2001DW |
| Provide 12 Inch RCP Storm Pipe |
| LF |
| 250 |
| 2001DX |
| Provide 24 Inch RCP Storm Pipe |
| LF |
| 125 |
| 2002DX |
| Provide 6 Inch Underdrain |
| LF |
| 5625 |
| 2001DY |
| Rebuild and Adjust Inlet |
| EA |
| 25 |
| 2001DZ |
| Rebuild and Adjust Manhole |
| EA |
| 25 |
| 2001EA |
| Provide Inlet |
| EA |
| 50 |
| 2001EB |
| Provide Manhole |
| EA |
| 5 |
| 2001EC |
| Provide Adjusting Ring For Manhole |
| EA |
| 25 |
| 2001ED |
| Provide Hydrostatic and Leak Test For Water Lines |
| EA |
| 3 |
| 2001EE |
| Provide Bacteriological Test For Water Lines |
| EA |
| 3 |
| 2001EF |
| Provide Leakage Test For Storm or Sanitary Lines |
| EA |
| 3 |
| 2001EG |
| Provide Deflection Test For Storm or Sanitary Lines |
| EA |
| 3 |
| 2001EH |
| Testing Concrete For Strength, Air Content and Slump |
| EA SHIFT |
| 3 |
| 2001EI |
| Testing Soil For Optimum Moisture Content and Maximum Laboratory Density |
| EA |
| 3 |
| 2001EJ |
| Testing Soil For Field Density |
| EA |
| 3 |
| 2001EK |
| Testing Aggregate Base Course For Optimum Moisture Content and Maximum Laboratory Density |
| EA |
| 3 |
| 2001EL |
| Testing Aggregate Base Course For Field Density |
| EA |
| 3 |
| 2001EM |
| Testing Bituminous Base Course For Field Density |
| EA |
| 3 |
| 2001EN |
| Testing Hot-Mix Asphalt As Specified |
| EA LOT |
| 3 |
Total for Option Year 2