Attachment_2_Drawings_181050.pdf
PDF 21 MB Posted
- Attached to
- On Call Base Wide Paving and Grounds Federal contract opportunity
- Solicitation number
- FA860119RA011
About this file
This document package includes drawings and technical specifications for concrete work and aircraft tie-downs at Wright-Patterson Air Force Base. The drawings provide details for reinforced concrete pads, anchors, and associated site work to support parking and tie-downs for military aircraft. Specifications require the use of corrosion-resistant stainless steel and epoxy-coated rebar. Sustainability requirements include recycling construction waste and protecting existing trees and vegetation. Offerors must verify dimensions and comply with Unified Facilities Criteria, engineering codes, and Air Force standards.
The related federal contract opportunity is for on-call maintenance, repair, and alteration of pavements, grounds, roads, parking lots, sidewalks, and security infrastructure at Wright-Patterson Air Force Base. Additional concrete, asphalt, excavation, and landscaping work may be ordered on an as-needed basis. The solicitation was issued by the Department of the Air Force Materiel Command Lifecycle Management Center located at Wright-Patterson Air Force Base.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment_4_Bid_Sched_Opt_1_181050.docx | DOCX document | |
| Attachment_5_Bid_Sched_Opt_2_181050.docx | DOCX document | |
| Attachment_3_Bid_Sched_Base_Yr_181050.docx | DOCX document | |
| Attachment_8_Addendum_1_Sect_L_&_M_Tables.docx | DOCX document | |
| Attachment_7_WDOL.pdf | ||
| Solicitation_-_FA860119RA011.pdf | ||
| Attachment_1_Specifications_181050.pdf | ||
| Attachment_6_TEP_Calculation.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES
1. ALL METAL AND WIRING SHALL TO BE RECYCLED AT THE WPAFB BASE RECYCLING CENTER. THE WPAFB RECYCLING CENTER IS AVAILABLE FOR CONTRACTOR USE TO REDUCE WASTE DISPOSAL. ALL RECYCLABLE METAL IS TO BE
RECYCLED THROUGH THE BASE RECYCLING CENTER. ALL RECYCLING MUST BE ACCOMPLISHED IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 02 20. CONTACT WPAFB RECYCLING PROGRAM MANAGER AT 937-257-5060
TO CONFIRM WHAT MATERIALS ARE RECYCLABLE AND TO COORDINATE TURN-IN. THE CONTRACTOR SHALL SUBMIT A QUARTERLY SUMMARY REPORT TO THE GOVERNMENT CONTRACT REPRESENTATIVE IAW WPAFB
SPECIFICATION SECTION 01 02 20 STATING (1) THE COST TO RECYCLE AND THE TONNAGE OF CONSTRUCTION AND DEMOLITION MATERIALS RECYCLED, (2) THE COST TO DIVERT/REUSE THE TONNAGE OF CONSTRUCTION AND
DEMOLITION MATERIALS DIVERTED/REUSE, (3) THE COST TO MULCH AND THE TONNAGE AND COST OF CONSTRUCTION AND DEMOLITION MATERIALS MULCHED, (4) THE COST FOR WASTE-TO-ENERGY AND THE TONNAGE OF
CONSTRUCTION AND DEMOLITION MATERIALS CONVERTED FROM WASTE-TO-ENERGY, (5) THE COST TO LANDFILL AND THE TONNAGE OF CONSTRUCTION AND DEMOLITION MATERIALS LAND-FILLED, (6) THE COST TO INCINERATE
AND THE TONNAGE OF CONSTRUCTION AND DEMOLITION MATERIALS INCINERATED, AND (7) EXPLANATION OF THE DIVERSION RATE IF LESS THAN 60%. THE QUARTERLY SUMMARY REPORTS SHALL BE RECEIVED ON APRIL 7, JULY
7, OCTOBER 7, AND JANUARY 7 COVERING THE THREE MONTHS PRIOR. THE QUARTERLY SUMMARY REPORTS SHALL BE ON THE WPAFB DIVERSION FORM. FOR ADDITIONAL INFORMATION CONTACT THE RECYCLING PM, DAVE
DALTON, AT 937-257-5060 OR DAVID.DALTON.2@US.AF.MILTURN-IN ALL MERCURY CONTAINING DEVICES, SWITCHES AND THERMOSTATS TO 88 CEG/CEIE IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 02 20 FOR
RECYCLING.
2. WHERE TREES, SHRUBS, FENCE, SIGNS, LIGHT POLES, AND OTHER MISCELLANIOUS ITEMS ARE REMOVED, THE CONTRACTOR SHALL PROTECT ITEMS TO REMAIN AND IF DAMAGED, REPAIR AT NO ADDITIONAL COST. SHOULD
CUTTING OR REMOVAL OF TREES BE NECESSARY, PRIOR TO ANY ACTION, A DETAILED REPORT CONTAINING THE LOCATION, NUMBER, TYPE, AND SIZE OF TREE(S) SHALL BE COORDINATED WITH THE 88 CEG/CEIE (NRPM) NATURAL
RESOURCES PROGRAM MANAGER (257-4857).
3. PROJECTS THAT DISTURB LESS THAN AN ACRE OF SOIL, AN EROSION CONTOL PLAN IS REQUIRED PRIOR TO SOIL DISTURBANCE. FOR PROJECTS THAT DISTURB MORE THAN AN ACRE A NOTICE OF INTENT (NOI) MUST BE APPROVED
BY THE OHIO EPA PRIOR TO ANY SOIL BEING DISTURBED AS WELL AS A STORM WATER POLLUTION PREVENTION PLAN (SWPPP) APPROVED BY 88CEG/CEIEA WATER PROGRAM MANAGER (937-257-5889).
4. ANY USE OF RADIOACTIVE MATERIALS BY THE CONTRACTOR, INCLUDING MOISTURE DENSITY GAUGES, MUST BE APPROVED BY THE WPAFB RADIATION SAFETY OFFICER A MINIMUM OF 30 DAYS PRIOR TO BEING BROUGHT ONTO
WPAFB. THIS REQUIREMENT IS FROM WPAFBI 40-201 AND WPAFB SPECIFICATION SECTION 01 02 20.
5. ALL HAZARDOUS MATERIALS MUST BE PROPERLY MANAGED, LABELED AND STORED. ANY HAZARDOUS WASTE
GENERATED FROM THIS CONSTRUCTION ACTIVITY MUST BE PROPERLY CHARACTERIZED, LABELED AND
MANAGED BY TRAINED EMPLOYEE OF THE CONTRACTOR WITH KNOWLEDGE OF THE ACTIVITY / PROCESS WHERE
THE WASTE WAS GENERATED. ALL HAZARDOUS WASTE WILL BE TURNED OVER TO THE GOVT FOR DISPOSAL. IN
ADDITION PROPER COORDINATION IS NEEDED WITH 88 CEG/CEIEC. QUESTIONS CONCERNING THE
REQUIREMENTS FOR STORAGE AND DISPOSAL OF ANY HAZARDOUS MATERIALS CAN BE ADDRESSED BY THE 88
CEG/CEIEC HAZARDOUS MATERIALS PM, MIKE VAUGHN, (937-257-8028 OR MICHAEL.VAUGHN.3@US.AF.MIL) OR 88
CEG/CEIEC HAZARDOUS WASTE PM, GARY SELBY (937-257-3349 OR GARY.SELBY@US.AF.MIL).
6. PRIOR TO REMOVING/TRIMMING ANY TREES, SUBMIT A LIST OF THE TREES TO BE REMOVED TO THE 88
CEG/CEIEA NATURAL RESOURCES PM DARRYN WARNER FOR APPROVAL. THREE TREES SHOULD BE REPLACED
FOR EVERY ONE TREE REMOVED. THE GENERAL 10-20-30 DIVERSITY RULE SHOULD BE FOLLOWED WHEN
PLANTING TREES. ONLY PLANTS/TREES ON THE APPROVED PLANTING LIST CAN BE PLANTED AND MUST BE OHIO
NATIVES. CONTACT DARRYN WARNER AT DARRYN.WARNER@US.AF.MIL OR 937-257-4857 FOR AN ACCEPTABLE
TREE REPLACEMENT LISTING OR ADDITIONAL INFORMATION
7. THE GENERATION OF FUGITIVE EMISSIONS MUST BE KEPT TO A MINIMUM USING APPROVED DUST SUPPRESSING
METHODS SUCH AS WATER SPRAYS ON AREA OF HIGH DUST GENERATION. FOR ADDITIONAL INFORMATION
PLEASE CONTACT THE 88 CEG/CEIEA AIR PM CHRIS TUMBUSCH AT 937-257-2455 OR
CHRISTOPHER.TUMBUSCH@US.AF.MIL
Attachment 2
FA8601-19-R-A011
W e s t
R a m p
LOCATION MAP - AREA A
SCALE: NTS
N
LOCATION MAP - AREA B
SCALE: NTS
N
DRH
DRH 5-21-18
4 OF27
C-3
WRL
5-21-18
5 27
C-4
WRL
6 27
C-5
WRL
7 27
C-6
WRL
8 27
C-7
WRL
3/8
3/16
3/16
3/8
3/16
3/16
ˆ ƒ ƒ ƒ
Œ
1/4
1/4
1/2
1/41/2
1/4
1/2
3/4
0.75
3/4
1/2
3/8 1/2
0.75
GENERAL NOTES
1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, ETC. NECESSARY FOR ACCURATE CONSTRUCTION AND
ALIGNMENT OF THE NEW TO THE EXISTING STRUCTURE. THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS NECESSARY
FOR PROPER FABRICATION AND ERECTION OF ALL STRUCTURAL MEMBERS.
2. THE CONTRACTOR SHALL ADHERE TO ALL UNIFIED FACILITIES CRITERIA, UFGS, AFI, APPLICABLE ENGINEERING AND
CONSTRUCTION CODES, ETC.
STRUCTURAL NOTES:
CONCRETE:
1. CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI 301-16 (SPECIFICATIONS FOR CONCRETE STRUCTURES), EXCEPT AS
MODIFIED BY THE SUPPLEMENTAL REQUIREMENTS BELOW.
2. EPOXY COATING OF REINFORCING BAR SHALL CONFORM TO THE SPECIFICATIONS FOR ASTM A934/A934M ON ASTM 615/615M GRADE 60
DEFORMED AND PLAIN CARBON STEEL REINFORCING BARS. THESE SHALL BE PREFABRICATED PRIOR TO SURFACE PREPARATION AND
COATED WITH PROTECTIVE FUSION-BONDED EPOXY COATING BY ELECTROSTATIC SPRAY.
3. ALL WELDING OF 316L STAINLESS STEEL SHALL BE PERFORMED BY CERTIFIED WELDERS AND SHALL CONFORM TO THE AMERICAN WELDING
SOCIETY STANDARD FOR WELDING. WELDING SHALL CONFORM TO ASTM A554/A554M
CONCRETE COATING:
1. APPLY SIKALASTIC 720/745 AL (55MILS TOTAL DRY FILM THICKNESS EXCLUSIVE OF AGGREGATE), HEAVY DUTY TRAFFIC SYSTEM TO THE TOP
SURFACES OF ALL THE NEW CONCRETE PAD STRUCTURES; APPLY SIKA 720/745 AL IN STERN CONFORMANCE WITH THE SPECIFICATIONS OF THE
SIKA CORPORATION, USA.
2. SIKALASTIC 720/745 AL (55MILS) HEAVY DUTY TRAFFIC SYSTEM IS A TWO COMPONENT, CHEMICALLY CURED, ELASTOMETRIC POLYURETHANE
COATING SYSTEM, DESIGNED FOR USE AS A WATERPROOFING MEMBRANE FOR PEDESTRIAN FLOORS AND VEHICULAR TRAFFIC BEARING
SURFACES; IMPERVIOUS TO WATER AND CORROSIVE INDUSTRIAL CHEMICALS.
REMOVAL NOTES
1. SCORE (OR NOTCH) THE TOP SURFACE OF THE SLAB, ALONG THE DIVIDING LINES BETWEEN THE CONCRETE REMOVAL AREA, AND THE REMAINING UNDAMAGED EXISTING CONCRETE STRUCTURES. SCORE INTO THE CONCRETE SLAB BY SAW CUTTING
12-INCH MAXIMUM DEEP INTO THE EXISTING SLAB.
2. ENSURE EXCAVATED HOLE IS CLEANED, FREE OF CUTTING AND GROUND WATER, PRIOR TO INSTALLATION OF 316L STAINLESS
STEEL ANCHOR AND CONCRETE. NOTIFY GOVERNMENT FOR INSPECTIONS AND APPROVAL AFTER THE HOLE HAS BEEN
EXCAVATED (DRILLED), BEFORE PLACING REINFORCEMENT AND FRESH CONCRETE.
LOCATION MAP: WPAFB AREA B, NATIONAL MUSEUM OF THE US AIR FORCE
SCALE: NTS
WORK
LOCATION
TOPOGRAPHIC SITE MAP, ONE OF TWO, TYPICAL
SCALE: NTS
N
PROVIDE TIE DOWN AND PAD FOR NMUSAF
C
GENERAL
LOCATION
OF
WORK
AREA
ELECTRICAL NOTES:
ELECTRICAL GROUNDING ROD
1. WELD #2 COPPER WIRE TO 1/2" DIAMETER COPPER CLAD 10-FT VERTICAL GROUNDING ROD AND TO EACH 316L STAINLESS STEEL ANCHOR
USING EXOTHERMIC WELD IN CONFORMANCE WITH NEC 2017 STANDARDS. STAINLESS STEEL ANCHORS SHALL NOT BE WELDED DIRECTLY TO
GROUNDING ROD.
2. ENSURE 1/2" DIAMETER COPPER CLAD 10-FT VERTICAL ROD IS PLACED AT LEAST 6 INCHES BELOW TOP SURFACE OF CONCRETE ANCHOR
CYLINDER AND AT MINIMUM 4 FT BELOW THE BOTTOM END OF THE CONCRETE ANCHOR CYLINDER IN ACCORDANCE WITH NEC 2017.
GROUNDING ROD MUST BE IN CONTACT WITH EARTH.
73'-6"
37'-11 2"
8'-11 2"
'-6
13'-9" 19'
'-6
6'- 9"
37'-11 2"
'-2
15 16
'-1
01 2"
58'-6"
4'- 7"
6'-
7 16
'-5
15 16
'-7
1 2"
73'-6"
16'-11 2"
'-7
1 2"
'-3
21'
21'-41 2"
9'- 79 16
58'-6"
10'-6"
'-1
115 16
PLAN: CONCRETE PAD AND ANCHOR SHOWING C-5 / VC-25 AIRCRAFT FOOTPRINT
SCALE: 3/16" = 1'-0"
37'-11 2"
'-5
15 16
8'-11 2"
'-1
115 16
10'-6"
37'-11 2"
'-7
1 2"
'-1
01 2"
73'-6"
21'
58'-6"
6'- 9"
'-6
6'-
7 16
'-6
19'
9'- 79 16
'-7
1 2"
13'-9"
'-2
15 16
73'-6"
21'-41 2"16'-11
2"
4'- 7"
'-3
NEW REINFORCED
CONCRETE PAD
NEW REINFORCED
CONCRETE PAD
NEW REINFORCED
CONCRETE PAD
C14
C14
C14
C14
C14
58'-6"
C13
C13
C13
C13
EXISTING ASPHALT SURFACE
'-0
4" ODOT #57 STONE BASE
COMPACTED TO 98%
MAXIMUM DRY DENSITY
EXISTING SUBGRADE
#4 EPOXY COATED STEEL BAR @
12" CENTER-TO-CENTER, TOP
AND BOTTOM OF CONCRETE PAD,
EACH WAY.
EXISTING CONCRETE SLAB
12" 4000PSI REINFORCED
CONCRETE PAD
2" C
LE
AR
5'- 0"
APPLY SIKLASTIC 720/ 745 AL (55MILS TOTAL DRY
THICKNESS EXCLUSIVE OF AGGREGATE), HEAVY DUTY
TRAFFIC SYSTEM TO THE TOP SURFACES OF ALL THE
NEW CONCRETE PAD STRUCTURE; APPLY SIKA 720/ 745
AL IN STERN CONFORMANCE WITH THE SPECIFICATIONS
OF THE SIKA CORPORATION.
2" C
LE
AR
TOP SURFACE OF
CONCRETE PAD: 825FT
4" ODOT #57 STONE BASE
COMPACTED TO 98%
MAXIMUM DRY DENSITY.
#4 EPOXY COATED STEEL BAR @
12" CENTER-TO-CENTER, TOP
AND BOTTOM OF CONCRETE PAD,
EACH WAY.
EXISTING CONCRETE SLAB
12" 4000PSI REINFORCED
CONCRETE PAD
APPLY SIKLASTIC 720/ 745 AL (55MILS TOTAL DRY
THICKNESS EXCLUSIVE OF AGGREGATE), HEAVY DUTY
TRAFFIC SYSTEM TO THE TOP SURFACES OF ALL THE
NEW CONCRETE PAD STRUCTURE; APPLY SIKA 720/ 745
AL IN STERN CONFORMANCE WITH THE SPECIFICATIONS
OF THE SIKA CORPORATION.
TOP SURFACE OF
CONCRETE PAD: 825FT
EXISTING ASPHALT SURFACE
2" C
LE
AR
5'- 0"
'-0
EXISTING SUBGRADE
2" C
LE
AR
ELEVATION DETAIL: REINFORCED CONCRETE PAD
SCALE: 1" = 1'-0"
C13
ELEVATION DETAIL: REINFORCED CONCRETE PAD
SCALE: 1" = 1'-0"
C13
TIE BARS: #4 EPOXY COATED
HOOP STEEL BARS @ 12"
CENTER-TO-CENTER ALONG
CONCRETE ANCHOR CYLINDER.
#9 LONGITUDINAL EPOXY COATED
BARS @ EQUAL SPACING
CENTER-TO-CENTER, AROUND
CONCRETE CYLINDER HOOP TIE
BARS, AS SHOWN.
38" DIAMETER 4000PSI CONCRETE
ANCHOR CYLINDER
#4 EPOXY COATED STEEL BARS @
12" CENTER-TO-CENTER, TOP AND
BOTTOM OF 12" CONCRETE PAD,
AS SHOWN ON DETAIL 1.1/S5.
10"x7-3/4"x5-5/8" 316L STAINLESS
22 GAGE STEEL COVER BOX
WITH 1-3/4" STAINLESS STEEL
INVERTED U-BAR.
1-3/4" DIAMETER 316L STAINLESS
STEEL SHOP WELDED ANCHOR
CROSS BARS AT VERTICAL SPACING
OF 12" CENTER-TO-CENTER. PLACE
BOTTOM CROSS BAR AT THE END OF
INVERTED U-BAR. SEE DETAIL 1.1/S5.
1-3/4" DIAMETER 316L STAINLESS
STEEL INVERTED U-BAR BY
MANUFACTURER SPECIFICATIONS
OR EQUAL WITH CROSS BARS AS
INDICATED ON DETAIL 1.1/S5.
NEW 4000PSI REINFORCED
CONCRETE PAD
1.1 1.1
S5S5
1/2" DIAMETER COPPER CLAD, 10-FT VERTICAL
GROUNDING ROD. EXOTHERMICALLY WELD #2
COPPER WIRE TO 1-3/4" STAINLESS STEEL INVERTED
U-BAR AND TO VERTICAL GROUNDING ROD. SEE
DETAIL 1/S6.
#9 LONGITUDINAL EPOXY COATED
BARS @ EQUAL SPACING
CENTER-TO-CENTER, AROUND
CONCRETE CYLINDER HOOP TIE
BARS. SEE DETAIL 1/S5.
#4 EPOXY COATED STEEL BAR
@ 12" CENTER-TO-CENTER,
TOP AND BOTTOM OF
CONCRETE PAD, EACH WAY.
1-3/4" DIAMETER 316L STAINLESS
STEEL INVERTED U-BAR WITH 1-3/4"
DIAMETER SHOP WELDED ANCHOR
CROSS BARS. SEE 1/S6 FOR
ANCHOR DETAIL..
1-3/4" DIAMETER 316L STAINLESS
STEEL CROSSBARS SHOP WELDED TO
1-3/4" DIAMETER 316L STAINLESS
STEEL INVERTED U-BAR @ 12"
CENTER-TO-CENTER. SEE DETAIL 1/S6.
12" 4000PSI REINFORCED
CONCRETE PAD
38" DIAMETER 4000PSI
CONCRETE ANCHOR
CYLINDER. SEE DETAIL 1/S5.
'-0
'-0
1 16
38'-0"
'-0
TIE BARS: #4 EPOXY COATED
INTERMEDIATE HOOP STEEL
BARS @ 12" CENTER-TO-CENTER
ALONG CONCRETE ANCHOR
CYLINDER.
'-0
4" ODOT #57 STONE BASE
COMPACTED TO 98%
MAXIMUM DRY DENSITY.
EXISTING SUBGRADE
7'- 6"
3'-01
8" CLEAR
2'-8"
2'- 0"
C
LE
AR
'-0
1/2" DIAMETER COPPER CLAD,
10-FT VERTICAL GROUNDING ROD.
EXOTHERMICALLY WELD #2
COPPER WIRE TO 1-3/4" STAINLESS
STEEL INVERTED U-BAR AND TO
VERTICAL GROUNDING ROD. SEE
DETAIL 1/S6.
3" C
LE
AR
2.1
S5
2.1
S5
TIE BARS: #4 EPOXY COATED
HOOP STEEL BARS @ 12"
CENTER-TO-CENTER ALONG
CONCRETE ANCHOR CYLINDER.
1-3/4" DIAMETER 316L STAINLESS
STEEL SHOP WELDED ANCHOR
CROSS BARS AT VERTICAL SPACING
OF 12" CENTER-TO-CENTER. PLACE
BOTTOM CROSS BAR AT THE END OF
INVERTED U-BAR. SEE DETAIL 2.1/S5.
1-3/4" DIAMETER 316L STAINLESS
STEEL INVERTED U-BAR BY
MANUFACTURER SPECIFICATIONS
OR EQUAL WITH CROSS BARS AS
INDICATED ON DETAIL 2.1/S5.
#9 LONGITUDINAL EPOXY COATED
BARS @ EQUAL SPACING
CENTER-TO-CENTER, AROUND
CONCRETE CYLINDER HOOP TIE
BARS, AS SHOWN.
38" DIAMETER 4000PSI CONCRETE
ANCHOR CYLINDER
10"x7-3/4"x5-5/8" 316L STAINLESS
22 GAGE STEEL COVER BOX
WITH 1-3/4" STAINLESS STEEL
INVERTED U-BAR.
EXISTING ASPHALT SURFACE
EXISTING ASPHALT SURFACE
38" DIAMETER 4000PSI
CONCRETE ANCHOR
CYLINDER. SEE DETAIL 2/S5.
9'- 0"
'-3
1 16
5'- 71 2"
EXISTING SUBGRADE
'-0
1-3/4" DIAMETER 316L STAINLESS
STEEL CROSSBARS SHOP WELDED TO
1-3/4" DIAMETER 316L STAINLESS
STEEL INVERTED U-BAR @ 12"
CENTER-TO-CENTER. SEE DETAIL 1/S6.
EXISTING ASPHALT SURFACE
'-0
28'-6"
TIE BARS: #4 EPOXY COATED
INTERMEDIATE HOOP STEEL
BARS @ 12" CENTER-TO-CENTER
ALONG CONCRETE ANCHOR
CYLINDER.
9'- 0"
2'-31
8" CLEAR2'-8"
3'- 0"
EXISTING CONCRETE SURFACE
1/2" DIAMETER COPPER CLAD,
10-FT VERTICAL GROUNDING ROD.
EXOTHERMICALLY BOND #2
COPPER WIRE TO 1-3/4" STAINLESS
STEEL INVERTED U-BAR AND TO
VERTICAL GROUNDING ROD. SEE
DETAIL 1/S6.
2" C
LE
AR
3" C
LE
AR
1-3/4" DIAMETER 316L STAINLESS
STEEL INVERTED U-BAR WITH 1-3/4"
DIAMETER SHOP WELDED ANCHOR
CROSS BARS. SEE 1/S6 FOR
ANCHOR DETAIL..
#9 LONGITUDINAL EPOXY COATED
BARS @ EQUAL SPACING
CENTER-TO-CENTER, AROUND
CONCRETE CYLINDER HOOP TIE
BARS. SEE DETAIL 1/S5.
SECTION DETAIL: THRU REINFORCED CONCRETE PAD ANCHOR CYLINDER
SCALE: 1" = 1'-0"
C14
1.1
SECTION DETAIL: THRU ASPHALT PAVEMENT, CONCRETE ANCHOR
SCALE: 1" = 1'-0"
C14
2.1
PLAN DETAIL: REINFORCED CONCRETE PAD AND ANCHOR
SCALE: 1" = 1'-0"
C14
PLAN DETAIL: REINFORCED CONCRETE CYLINDER
SCALE: 1" = 1'-0"
C14
'-0
1-3/4" DIAMETER 316L STAINLESS
STEEL INVERTED U-BAR
'-0
'-0
1-3/4" DIAMETER 316L STAINLESS
STEEL CROSSBARS SHOP WELDED
TO 1-3/4" DIAMETER 316L STAINLESS
STEEL INVERTED U-BAR @ 12"
CENTER-TO-CENTER, AS SHOWN.
9'-
13 16
5'-0"
6"
'-5 15 16
'-5 7 8"
3'-6"
6'- 9"
1-3/4" DIAMETER 316L STAINLESS
STEEL CROSSBARS SHOP WELDED
TO 1-3/4" DIAMETER 316L STAINLESS
STEEL INVERTED U-BAR @ 12"
CENTER-TO-CENTER, AS SHOWN.
3'- 3"
PLACE 1-3/4" DIAMETER
BOTTOM CROSSBARS AT
BOTTOM END OF INVERTED
U-BAR AS INDICATED.
'-5
7 8" 6"
'-1
115 16
'-5
7 8"
16'-0"
1/2" DIAMETER COPPER CLAD,
10-FT VERTICAL GROUNDING ROD.
EXOTHERMICALLY WELD #2
COPPER WIRE TO 1-3/4" STAINLESS
STEEL INVERTED U-BAR AND TO
VERTICAL GROUNDING ROD.
1-3/4" DIAMETER 316L STAINLESS
STEEL CROSSBARS SHOP WELDED
TO 1-3/4" DIAMETER 316L STAINLESS
STEEL INVERTED U-BAR @ 12"
CENTER-TO-CENTER, AS SHOWN.
4'-6 1 16"4'-6"
1/2" DIAMETER COPPER CLAD,
10-FT VERTICAL GROUNDING ROD.
EXOTHERMICALLY WELD #2
COPPER WIRE TO 1-3/4" STAINLESS
STEEL INVERTED U-BAR AND TO
VERTICAL GROUNDING ROD.
'-1
115 16
'-0
9'-
13 16
16" 5 6
16"
BOTTOM END OF 1/2" DIAMETER COPPER
CLAD GROUNDING ROD SHALL BE AT
MINIMUM 4'-0" FROM BOTTOM CROSS BAR.
1-3/4" DIAMETER 316L STAINLESS
STEEL INVERTED U-BAR
1-3/4" DIAMETER 316L STAINLESS
STEEL INVERTED U-BAR
1/2" DIAMETER COPPER CLAD,
10-FT VERTICAL GROUNDING ROD.
EXOTHERMICALLY WELD #2
COPPER WIRE TO 1-3/4" STAINLESS
STEEL INVERTED U-BAR AND TO
VERTICAL GROUNDING ROD.
OFFSET GROUNDING ROD NOT
LESS THAN 8" FROM STAINLESS
STEEL INVERTED U-BAR.
PLACE 1-3/4" DIAMETER
BOTTOM CROSSBAR AT
BOTTOM END OF INVERTED
U-BAR AS INDICATED.
5'- 0"
3'-6" 3'-6"
15'-1115 16"
'-0
10"
3'-6"
BOTTOM END OF 1/2" DIAMETER COPPER
CLAD GROUNDING ROD SHALL BE AT
MINIMUM 4'-0" FROM BOTTOM CROSS BAR.
DETAIL: STAINLESS STEEL ANCHOR AND GROUNDING ROD
SCALE: 1" = 1'-0"
C15
1/4
1/4
3/8
1/4 3/8 1/2
5/8
5/8
3/16
3/16
5/32
3/8
1 4
Œ ˆ œ ƒ ƒ
3/4
1/4
1/2
3/4
1/2
3/4
3/4
1/4
3/4
1/4 ƒ
1/4
1/4
3/4
1/8
5/8
1/8
1/8
1/16
1/4
3/8
1/4
1/4 ƒ
5/8
3/4
3/4
3/4
3/4
5/8
3/4
3/4
3/4
3/4
| 01 G1 Cover Sheet New |
| 02 C1 Area A Map New |
| 03 C2 Area B Map New |
| 04 TO 08 TO Drawing Details C-3 thru C-7 new |
| 09 to10 0002AK Provide Bollard new |
| 11 TO 16 00002DJ NMUSAF TIE DOWNS new |
| 17 0002DX Provide 6 Underdrain new |
| 18 0002AL Provide Underground Duct Bank new |
| 19 TO 23 0003AP Provide Traffic Signal System new |
| 24 TO 25 0002AR Provide Parking Light new |
| 26 TO 27 0003AR Provide Street Light new |
File details come from the government source that posted it. Updated .