Questions and Answers #2:

23 Aug 18 1.) Do the shields needs to be certified to meet NIJ Level III? Most contracts require a third-party lab certification of the system versus a self-certification of the materials. With the quote/proposal, will third-party certifications be required?

A: Certification needs to be provided with quote submitted. This documentation needs to be performed by an independent company or DoD. We need to be able to review the results have the certification companies information to ensure that the shield can’t be stopped by 5.56 and 7.62 rounds.