S-102E
56 TUNNEL PHOTOS/DESCRIPTIONS
COORDINATOR ENGINEERING CHIEF
DATE REVISION BYNO. DATE NO. REVISION BY
C I
V
IL
ENGI
N
E E
R
US AF
WRIGHT-PATTERSON AIR FORCE BASE
88TH ABW
OF
DESIGN CHIEF
DATEDRAWNDESIGNED CHECKED
RPR/RPL STEAM STANCHIONS
PROJECT NUMBER ZHTV 090018
SUBMITTAL - 100% GOVT. SUBMITTAL
SPR SPR MSS JUNE 2015
EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE
EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE
EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE
BASE OF TUNNEL
STANDING WATER PRESENT ALONG
TOWARDS STANCHION 90 &
VIEW DOWN LENGTH OF TUNNEL
102E-a 102E-b 102E-c
102E-f102E-e102E-d
102E-g 102E-h
AT STANCHION 85.
CORROSION & LOSS OF STEEL SECTION
LEGS & CONNECTION CHANNELS HAVE
OF TUNNEL. BASE OF VERTICAL SUPPORT
STANDING WATER PRESENT ALONG BASE
WIDTH OF CEILING AT STANCHION 86.
& WATER INTRUSION PRESENT ALONG
& LOSS OF STEEL SECTION. CRACKING
HORIZONTAL ROD SUPPORT HAVE CORROSION
TOP OF VERTICAL SUPPORT LEGS &
SUPPORT AT STANCHION 87.
SUPPORT MISSING ON BOTTOM HORIZONTAL
LOSS OF STEEL SECTION. PIPE ROLLER
& CONNECTION PLATES HAVE CORROSION &
TUNNEL. BASE OF VERTICAL SUPPORT LEGS
STANDING WATER PRESENT ALONG BASE OF
ALONG WIDTH OF CEILING AT STANCHION 88.
LEGS. CRACKING & WATER INTRUSION PRESENT
SUPPORT NOT BEARING AT VERTICAL SUPPORT
& LOSS OF STEEL SECTION. TOP HORIZONTAL ROD
TOP PORTION OF SUPPORT LEGS HAVE CORROSION
STEEL SECTION AT STANCHION 88.
LEGS HAVE CORROSION & LOSS OF
OF TUNNEL. BASE OF VERTICAL SUPPORT
STANDING WATER PRESENT ALONG BASE
AT STANCHION 89.
CORROSION & LOSS OF STEEL SECTION
LEGS & CONNECTION CHANNELS HAVE
OF TUNNEL. BASE OF VERTICAL SUPPORT
STANDING WATER PRESENT ALONG BASE
SECTION AT STANCHION 89.
CORROSION & LOSS OF STEEL
& HORIZONTAL ROD SUPPORT HAVE
TOP OF VERTICAL SUPPORT LEGS
1/S-303 FOR REPLACEMENT OF STANCHION DETAIL.
CLEAN AREA ADJACENT TO EXISTING STANCHION. SEE
REMOVE ALL STANDING WATER PRIOR TO NEW WORK.
PERFORMACE EFFICIENCY.
ROUTINE OBSERVATION TO SUMP PUMP FOR
NEED REPLACED. WPAFB MAINTENANCE TO PROVIDE
SUMP PUMP FUNCTIONS PROPERLY & DOES NOT
PER CONVERSATION w/ WPAFB TUNNEL MAINTENANCE, INJECTION REPAIR DETAIL.
DETAIL & 3A/S-301 FOR CONCRETE CRACK
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
DETAIL.
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
REMOVE ALL STANDING WATER PRIOR TO NEW WORK.
WATERPROOFING APPLICATION.
INJECTION REPAIR, AND 2/S-301 FOR INTERNAL
DETAIL, 3A/S-301 FOR CONCRETE CRACK
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
1/S-303 FOR REPLACEMENT OF STANCHION DETAIL.
CLEAN AREA ADJACENT TO EXISTING STANCHION. SEE
REMOVE ALL STANDING WATER PRIOR TO NEW WORK.
OF THE STANCHION.
THE BASE OF THE WALL & AROUND THE BASE
2. CLEAN ALL LOOSE PIECES OF DEBRIS FROM
COATING.
APPLICATION OF A CORROSION RESISTANT
STEEL SHALL BE CLEANED TO ALLOW FOR
STANCHIONS (TO REMAIN) SHALL BE REMOVED.
1. ALL CORROSION PRESENT ON EXISTING STEEL
NOTES:
1/S-303 FOR REPLACEMENT OF STANCHION DETAIL.
CLEAN AREA ADJACENT TO EXISTING STANCHION. SEE
REMOVE ALL STANDING WATER PRIOR TO NEW WORK.
1/S-303 FOR REPLACEMENT OF STANCHION DETAIL.
CLEAN AREA ADJACENT TO EXISTING STANCHION. SEE
S-102F
56 TUNNEL PHOTOS/DESCRIPTIONS
COORDINATOR ENGINEERING CHIEF
DATE REVISION BYNO. DATE NO. REVISION BY
C I
V
IL
ENGI
N
E E
R
US AF
WRIGHT-PATTERSON AIR FORCE BASE
88TH ABW
OF
DESIGN CHIEF
DATEDRAWNDESIGNED CHECKED
RPR/RPL STEAM STANCHIONS
PROJECT NUMBER ZHTV 090018
SUBMITTAL - 100% GOVT. SUBMITTAL
SPR SPR MSS JUNE 2015
EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE
EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE
EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE
102F-b 102F-c
102F-f102F-e102F-d
102F-g 102F-h
CEILING NEAR STANCHION 90.
CRACKING ALONG WALL &
CONCRETE HONEYCOMBING &
INSULATED PIPE AT STANCHION 58.
TUNNEL OF ABANDONED
VIEW DOWN LENGTH OF
STANCHION 72.
UNINSULATED PIPE AT
102F-a
SECTION NEAR STANCHION 83.
CORROSION & LOSS OF STEEL
DUCT BANK SUPPORT STEEL HAS
AT STANCHION 90.
CORROSION & LOSS OF STEEL SECTION
LEGS & CONNECTION CHANNELS HAVE
OF TUNNEL. BASE OF VERTICAL SUPPORT
STANDING WATER PRESENT ALONG BASE
SPECS FOR PROPER DISPOSAL.
PIPING FROM STANCHIONS. REFER TO
63.
& TURNS VERTICAL) AT STANCHION
INSULATED PIPE (PIPE BENDS
TO SPECS FOR PROPER DISPOSAL.
PIPING FROM STANCHIONS. REFER
TO SPECS FOR PROPER DISPOSAL.
PIPING FROM STANCHIONS. REFER
PIPING BELOW NEAR STANCHION 83.
STEEL FALLEN OFF & RESTING ON
THROUGH TUNNEL WALLS. CORRODED
CEILING BETWEEN & PENETRATING
EXISTING DUCT BANK ALONG BOTTOM OF
OF STANCHION DETAIL
STANCHION. SEE 1/S-303 FOR REPLACEMENT
WORK. CLEAN AREA ADJACENT TO EXISTING
REMOVE ALL STANDING WATER PRIOR TO NEW
CONCRETE SURFACE SPALL REPAIR DETAIL.
REPAIR DETAIL AND 3B & 3C/S-301 FOR
SEE 3A/S-301 FOR CONCRETE CRACK INJECTION
3C/S-301 FOR CONCRETE SURFACE SPALL REPAIR DETAIL.
INTERNAL WATERPROOFING APPLICATION AND 3B &
TO SPECS FOR PROPER DISPOSAL. SEE 2/S-301 FOR
REMOVE PIPING TO UNDERSIDE OF CEILING SLAB. REFER
EXISTING DUCT BANK SUPPORT.
REMOVE ALL PIECES OF CORRODED STEEL FROM
DETAIL.
REFERENCE TO STEEL STANCHION REPLACEMENT
EXISTING DUCT BANK SUPPORT. SEE 1/S-303 FOR
REMOVE ALL PIECES OF CORRODED STEEL FROM
OF THE STANCHION.
THE BASE OF THE WALL & AROUND THE BASE
2. CLEAN ALL LOOSE PIECES OF DEBRIS FROM
COATING.
APPLICATION OF A CORROSION RESISTANT
STEEL SHALL BE CLEANED TO ALLOW FOR
STANCHIONS (TO REMAIN) SHALL BE REMOVED.
1. ALL CORROSION PRESENT ON EXISTING STEEL
NOTES: