S-104B
PHOTOS/DESCRIPTIONS
32 CROSSOVER TUNNEL
EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE
EXISTING CONDITION REPAIR PROCEDUREEXISTING CONDITION REPAIR PROCEDUREEXISTING CONDITION REPAIR PROCEDURE
EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE
104B-h104B-g
104B-d 104B-e 104B-f
104B-c104B-b104B-a
PRESENT ALONG BASE AT STANCHION 16.
MISSING AT BOTTOM SUPPORT. WATER INTRUSION
& LOSS OF STEEL SECTION. PIPE ROLLER
HORIZONTAL PIPE SUPPORT HAVE CORROSION
BASE OF VERTICAL SUPPORT LEGS & BOTTOM
PRESENT AT BASE OF WALL AT STANCHION 17.
BOTTOM SUPPORT. CRACKING & WATER INTRUSION
LOSS OF STEEL SECTION. PIPE ROLLER MISSING AT
HORIZONTAL PIPE SUPPORT HAVE CORROSION &
BASE OF VERTICAL SUPPORT LEGS & BOTTOM
AT STANCHION 19.
TO SAME HEIGHT AS OPPOSITE SUPPORT LEG
VERTICAL SUPPORT LEG DOES NOT EXTEND
AT STANCHION 20.
TO SAME HEIGHT AS OPPOSITE SUPPORT LEG
VERTICAL SUPPORT LEG DOES NOT EXTEND
PRESENT ALONG BASE AT STANCHION 20.
& PIPE ROLLERS MISSING. WATER INTRUSION
BOTTOM & CENTER HORIZONTAL PIPE SUPPORTS
CORROSION & LOSS OF STEEL SECTION.
BASE OF VERTICAL SUPPORT LEGS HAVE
PRESENT ALONG BASE AT STANCHION 21.
AT BOTTOM SUPPORT. WATER INTRUSION
& LOSS OF STEEL SECTION. PIPE ROLLER MISSING
HORIZONTAL PIPE SUPPORT HAVE CORROSION
BASE OF VERTICAL SUPPORT LEG & BOTTOM
INTRUSION PRESENT ALONG BASE AT STANCHION 23.
AT BOTTOM & CENTER SUPPORTS. WATER
LOSS OF STEEL SECTION. PIPE ROLLER MISSING
HORIZONTAL PIPE SUPPORT HAVE CORROSION &
BASE OF VERTICAL SUPPORT LEG & BOTTOM
INTRUSION PRESENT ALONG BASE AT STANCHION 24.
AT BOTTOM & CENTER SUPPORTS. WATER
& LOSS OF STEEL SECTION. PIPE ROLLER MISSING
HORIZONTAL PIPE SUPPORT HAVE CORROSION
BASE OF VERTICAL SUPPORT LEG & BOTTOM
APPLICATION
DETAIL & 2/S-301 FOR INTERNAL WATERPROOFING
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
APPLICATION
& 2/S-301 FOR INTERNAL WATERPROOFING
DETAIL, 3A/S-301 FOR CONCRETE CRACK REPAIR,
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
DETAIL.
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
DETAIL.
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
APPLICATION
DETAIL & 2/S-301 FOR INTERNAL WATERPROOFING
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
APPLICATION
DETAIL & 2/S-301 FOR INTERNAL WATERPROOFING
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
APPLICATION
DETAIL & 2/S-301 FOR INTERNAL WATERPROOFING
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
APPLICATION
DETAIL & 2/S-301 FOR INTERNAL WATERPROOFING
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
OF THE STANCHION.
THE BASE OF THE WALL & AROUND THE BASE
2. CLEAN ALL LOOSE PIECES OF DEBRIS FROM
COATING.
APPLICATION OF A CORROSION RESISTANT
STEEL SHALL BE CLEANED TO ALLOW FOR
STANCHIONS (TO REMAIN) SHALL BE REMOVED.
1. ALL CORROSION PRESENT ON EXISTING STEEL
NOTES: COORDINATOR ENGINEERING CHIEF
DATE REVISION BYNO. DATE NO. REVISION BY
C I
V
IL
ENGI
N
E E
R
US AF
WRIGHT-PATTERSON AIR FORCE BASE
88TH ABW
OF
DESIGN CHIEF
DATEDRAWNDESIGNED CHECKED
RPR/RPL STEAM STANCHIONS
PROJECT NUMBER ZHTV 090018
SUBMITTAL - 100% GOVT. SUBMITTAL
SPR SPR MSS JUNE 2015
S-104C
PHOTOS/DESCRIPTIONS
32 CROSSOVER TUNNEL
EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE
EXISTING CONDITION REPAIR PROCEDUREEXISTING CONDITION REPAIR PROCEDUREEXISTING CONDITION REPAIR PROCEDURE
EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE
104C-h104C-g
104C-d 104C-e 104C-f
104C-c104C-b104C-a
SUPPORT AT STANCHION 33.
CORROSION THROUGHOUT STEEL
SUPPORT AT STANCHION 34.
CORROSION THROUGHOUT STEEL
UNINSULATED PIPE AT STANCHION 23. UNINSULATED PIPE AT STANCHION 31.
PRESENT ALONG BASE AT STANCHION 25.
AT BOTTOM SUPPORT. WATER INSTRUSION
LOSS OF STEEL SECTION. PIPE ROLLER MISSING
HORIZONTAL PIPE SUPPORT HAVE CORROSION &
BASE OF VERTICAL SUPPORT LEGS & BOTTOM
PRESENT ALONG BASE AT STANCHION 29.
MISSING AT BOTTOM SUPPORT. WATER INTRUSION
& LOSS OF STEEL SECTION. PIPE ROLLER
HORIZONTAL PIPE SUPPORT HAVE CORROSION
BASE OF VERTICAL SUPPORT LEGS & BOTTOM
BASE AT STANCHION 33.
INTRUSION PRESENT ALONG
STEEL SECTION. WATER
HAVE CORROSION & LOSS OF
BASE OF VERTICAL SUPPORT LEGS
AT STANCHION 34.
WATER INTRUSION PRESENT ALONG BASE
CORROSION & LOSS OF STEEL SECTION.
BOTTOM HORIZONTAL PIPE SUPPORT HAVE
BASE OF VERTICAL SUPPORT LEGS &
TO SPECS FOR PROPER DISPOSAL.
PIPING FROM STANCHIONS. REFER
TO SPECS FOR PROPER DISPOSAL.
PIPING FROM STANCHIONS. REFER
APPLICATION.
DETAIL & 2/S-301 FOR INTERNAL WATERPROOFING
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
APPLICATION.
DETAIL & 2/S-301 FOR INTERNAL WATERPROOFING
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
DETAIL.
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
APPLICATION.
DETAIL & 2/S-301 FOR INTERNAL WATERPROOFING
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
DETAIL.
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
APPLICATION.
DETAIL & 2/S-301 FOR INTERNAL WATERPROOFING
SEE 1/S-303 FOR REPLACEMENT OF STANCHION
CLEAN AREA ADJACENT TO EXISTING STANCHION.
OF THE STANCHION.
THE BASE OF THE WALL & AROUND THE BASE
2. CLEAN ALL LOOSE PIECES OF DEBRIS FROM
COATING.
APPLICATION OF A CORROSION RESISTANT
STEEL SHALL BE CLEANED TO ALLOW FOR
STANCHIONS (TO REMAIN) SHALL BE REMOVED.
1. ALL CORROSION PRESENT ON EXISTING STEEL
NOTES:
COORDINATOR ENGINEERING CHIEF
DATE REVISION BYNO. DATE NO. REVISION BY
C I
V
IL
ENGI
N
E E
R
US AF
WRIGHT-PATTERSON AIR FORCE BASE
88TH ABW
OF
DESIGN CHIEF
DATEDRAWNDESIGNED CHECKED
RPR/RPL STEAM STANCHIONS
PROJECT NUMBER ZHTV 090018
SUBMITTAL - 100% GOVT. SUBMITTAL
SPR SPR MSS JUNE 2015