Attch__17-Drawings_S-105B_and_S-105C.pdf

PDF 12 MB Posted

Attached to
Repair-Replace Steam Pipe Stanchions
Solicitation number
FA8601-15-R-0030
Issued by

About this file

Attch 17-Drawings S-105B and S-105C

View the file

Other files

File Type Posted
Attch_61_Addend_03_Colored_S-105D-updated.pdf PDF
Attch_42_Addend_03_Colored_S-102A-updated.pdf PDF
Attch_43_Addend_03_Colored_S-102B-updated.pdf PDF
Attch_63Addend_03_Colored_S-105F-updated.pdf PDF
Attch_52_Addend_03_Colored_S-103C.pdf PDF
Attch_44_Addend_03_Colored_S-102C.pdf PDF
Attch_49_Addend_03_Colored_S-102H.pdf PDF
Attch_50_Addend_03_Colored_S-103A.pdf PDF
Attch_40_Addend_03_Colored_S-101G.pdf PDF
Attch_62_Addend_03_Colored_S-105E.pdf PDF
Attch_46_Addend_03_Colored_S-102E.pdf PDF
Attch_59_Addend_03_Colored_S-105B.pdf PDF
Attch_33_Addend_03_Colored_G-001.pdf PDF
Attch_36_Addend_03_Colored_S-101C.pdf PDF
Attch_51_Addend_03_Colored_S-103B.pdf PDF
Attch_53_Addend_03_Colored_S-104A.pdf PDF
Attch_54_Addend_03_Colored_S-104B.pdf PDF
Attch_43_Addend_03_Colored_S-102B.pdf PDF
Attch_63Addend_03_Colored_S-105F.pdf PDF
Attch_35_Addend_03_Colored_S-101B.pdf PDF
Attch_42_Addend_03_Colored_S-102A.pdf PDF
Attch_58_Addend_03_Colored_S-105A.pdf PDF
Attch_57_Addend_03_Colored_S-104E.pdf PDF
Attch_38_Addend_03_Colored_S-101E.pdf PDF
Attch_60_Addend_03_Colored_S-105C.pdf PDF
Attch_47_Addend_03_Colored_S-102F.pdf PDF
Attch_34_Addend_03_Colored_S-101A.pdf PDF
Attch_64_Addend_03_Colored_S-105G.pdf PDF
Attch_55_Addend_03_Colored_S-104C.pdf PDF
Attch_56_Addend_03_Colored_S-104D.pdf PDF
Attch_61_Addend_03_Colored_S-105D.pdf PDF
Attch_41_Addend_03_Colored_S-101H.pdf PDF
Attch_37_Addend_03_Colored_S-101D.pdf PDF
Attch_39_Addend_03_Colored_S-101F.pdf PDF
Attch_48_Addend_03_Colored_S-102G.pdf PDF
FA8601-15-R-0030-0002_Amendment_2.pdf PDF
Attch_45_Addend_03_Colored_S-102D.pdf PDF
RFI_0002.pdf PDF
RFI_0001.pdf PDF
FA8601-15-R-0030_Addendum_Number_02.pdf PDF
FFPAddendum(w_Modifications).pdf PDF
108001-00181-S-303.pdf PDF
Rules_of_Engagement.pdf PDF
Sign_In_Sheet_FA8601-15-R-0030.pdf PDF
Attch__15-Drawings_S-104D_and_S-104E.pdf PDF
Attch_8-Drawings_S-102C_and_S-102D.pdf PDF
Attch_1-Specifications.pdf PDF
Attch__14-Drawings_S-104B_and_S-104C.pdf PDF
Attch__18-Drawings_S-105D_and_S-105E.pdf PDF
Attch_19-Drawings_S-105F_and_S-105G.pdf PDF
Show 40 more

Latest 50 of 72 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S-105B 5th STREET TUNNEL PHOTOS/DESCRIPTIONS

EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE

EXISTING CONDITION REPAIR PROCEDUREEXISTING CONDITION REPAIR PROCEDUREEXISTING CONDITION REPAIR PROCEDURE

EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE

105B-c105B-b

105B-d 105B-e 105B-f

105B-h105B-g

44 & 46.

LOCATION BETWEEN STANCHIONS

CRACKING PRESENT NEAR SPALL

REBAR EXPOSED WITHIN CEILING.

CONCRETE SPALL & CORRODED

STANCHIONS 49 & 50.

MEMBER WITHIN CEILING BETWEEN

CONCRETE SPALL & CORRODED

CEILING & WALL AT STANCHION 55.

WITHIN CEILING. CRACKING PRESENT WITHIN

EXPOSED NEAR ABANDONED PIPE SLEEVE

CONCRETE SPALL & CORRODED REBAR

LOCATION BETWEEN STANCHIONS 60 & 63.

WITHIN CEILING PRESENT ACROSS SPALL

EXPOSED WITHIN CEILING. CRACKING

CONCRETE SPALL & CORRODED REBAR

BETWEEN STANCHIONS 60 & 63.

REBAR EXPOSED WITHIN CEILING

CONCRETE SPALL & CORRODED

60 & 63.

CEILING BETWEEN STANCHIONS

CORROSION VISIBLE THROUGHOUT

CONCRETE SPALL & CRACKING w/

STANCHIONS 60 & 63.

ALONG WIDTH OF TUNNEL BETWEEN

OR CRACK REPAIR MATERIAL PRESENT

EXPOSED WITHIN CEILING. JOINT FILLER

CONCRETE SPALL & CORRODED REBAR

105B-a

WITHIN CEILING BETWEEN STANCHIONS 49 & 50.

STEEL SECTION. WATER INSTRUSION PRESENT

SUPPORT LEGS HAVE CORROSION & LOSS OF

REBAR EXPOSED WITHIN CEILING. TOP OF VERTICAL

CONCRETE SPALL & CRACKING w/ CORRODED

OF CONCRETE TUNNEL DETAIL.

APPLICATION, & 2/S-303 FOR REPLACEMENT

DETAIL, 1/S-301 FOR EXTERNAL WATERPROOFING

SEE 1/S-303 FOR REPLACEMENT OF STANCHION

CLEAN AREA ADJACENT TO EXISTING STANCHION.

OF CONCRETE TUNNEL DETAIL.

APPLICATION AND 2/S-303 FOR REPLACEMENT

SEE 1/S-301 FOR EXTERNAL WATERPROOFING

OF CONCRETE TUNNEL DETAIL.

APPLICATION AND 2/S-303 FOR REPLACEMENT

SEE 1/S-301 FOR EXTERNAL WATERPROOFING

OF CONCRETE TUNNEL DETAIL.

APPLICATION, & 2/S-303 FOR REPLACEMENT

DETAIL, 1/S-301 FOR EXTERNAL WATERPROOFING

SEE 1/S-303 FOR REPLACEMENT OF STANCHION

CLEAN AREA ADJACENT TO EXISTING STANCHION.

OF CONCRETE TUNNEL DETAIL.

APPLICATION AND 2/S-303 FOR REPLACEMENT

SEE 1/S-301 FOR EXTERNAL WATERPROOFING

OF CONCRETE TUNNEL DETAIL.

APPLICATION AND 2/S-303 FOR REPLACEMENT

SEE 1/S-301 FOR EXTERNAL WATERPROOFING

OF THE STANCHION.

THE BASE OF THE WALL & AROUND THE BASE

2. CLEAN ALL LOOSE PIECES OF DEBRIS FROM

COATING.

APPLICATION OF A CORROSION RESISTANT

STEEL SHALL BE CLEANED TO ALLOW FOR

STANCHIONS (TO REMAIN) SHALL BE REMOVED.

1. ALL CORROSION PRESENT ON EXISTING STEEL

NOTES:

OF CONCRETE TUNNEL DETAIL.

APPLICATION AND 2/S-303 FOR REPLACEMENT

SEE 1/S-301 FOR EXTERNAL WATERPROOFING

OF CONCRETE TUNNEL DETAIL.

APPLICATION AND 2/S-303 FOR REPLACEMENT

SEE 1/S-301 FOR EXTERNAL WATERPROOFING

COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

RPR/RPL STEAM STANCHIONS

PROJECT NUMBER ZHTV 090018

SUBMITTAL - 100% GOVT. SUBMITTAL

SPR SPR MSS JUNE 2015

S-105C 5th STREET TUNNEL PHOTOS/DESCRIPTIONS

EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE

EXISTING CONDITION REPAIR PROCEDUREEXISTING CONDITION REPAIR PROCEDUREEXISTING CONDITION REPAIR PROCEDURE

EXISTING CONDITION REPAIR PROCEDURE EXISTING CONDITION REPAIR PROCEDURE

105C-c105C-b105C-a

105C-d 105C-e

105C-h105C-g

BETWEEN STANCHIONS 60 & 63.

REBAR EXPOSED WITHIN CEILING

CONCRETE SPALL & CORRODED

AT STANCHION 65.

REBAR EXPOSED WITHIN CEILING

CONCRETE SPALL & CORRODED

79.

ADJACENT TO JOINT AT STANCHION

REBAR EXPOSED WITHIN CEILING

CONCRETE SPALL & CORRODED

IN CEILING AT STANCHION 65.

REBAR EXPOSED AROUND VOID

CONCRETE SPALL & CORRODED

WITHIN CEILING AT STANCHION 81.

REBAR EXPOSED AROUND VOID

CONCRETE SPALL & CORRODED

WITHIN CEILING AT STANCHION 83.

CORRODED STEEL SUPPORTS PRESENT

PRESENT WITHIN WALL & CEILING.

EXPOSED WITHIN CEILING. CRACKING

CONCRETE SPALL & CORRODED REBAR

BETWEEN STANCHIONS 60 & 61.

EXIST STEAM PIPE EXPANSION JOINT

105C-f

STANCHION 3.

& LOSS OF STEEL SECTION AT

SUPPORT LEG HAS CORROSION

REBAR EXPOSED. TOP OF VERTICAL

CONCRETE SPALL & CORRODED

OF CONCRETE TUNNEL DETAIL.

APPLICATION AND 2/S-303 FOR REPLACEMENT

SEE 1/S-301 FOR EXTERNAL WATERPROOFING

OF CONCRETE TUNNEL DETAIL.

APPLICATION AND 2/S-303 FOR REPLACEMENT

SEE 1/S-301 FOR EXTERNAL WATERPROOFING

OF CONCRETE TUNNEL DETAIL.

APPLICATION AND 2/S-303 FOR REPLACEMENT

SEE 1/S-301 FOR EXTERNAL WATERPROOFING

OF CONCRETE TUNNEL DETAIL.

APPLICATION AND 2/S-303 FOR REPLACEMENT

SEE 1/S-301 FOR EXTERNAL WATERPROOFING

OF CONCRETE TUNNEL DETAIL.

APPLICATION AND 2/S-303 FOR REPLACEMENT

SEE 1/S-301 FOR EXTERNAL WATERPROOFING

OF CONCRETE TUNNEL DETAIL.

APPLICATION AND 2/S-303 FOR REPLACEMENT

SEE 1/S-301 FOR EXTERNAL WATERPROOFING

WATERPROOFING APPLICATION

SPALL REPAIR DETAIL, & 2/S-301 FOR INTERNAL

DETAIL, 3B & 3C/S-301 FOR CONCRETE SURFACE

SEE 1/S-303 FOR REPLACEMENT OF STANCHION

CLEAN AREA ADJACENT TO EXISTING STANCHION.

TO STEEL AT EXPANSION JOINT.

CORROSION RESISTANT COATING

CLEAN CORROSION AND APPLY A

OF THE STANCHION.

THE BASE OF THE WALL & AROUND THE BASE

2. CLEAN ALL LOOSE PIECES OF DEBRIS FROM

COATING.

APPLICATION OF A CORROSION RESISTANT

STEEL SHALL BE CLEANED TO ALLOW FOR

STANCHIONS (TO REMAIN) SHALL BE REMOVED.

1. ALL CORROSION PRESENT ON EXISTING STEEL

NOTES: COORDINATOR ENGINEERING CHIEF

DATE REVISION BYNO. DATE NO. REVISION BY

C I

V

IL

ENGI

N

E E

R

US AF

WRIGHT-PATTERSON AIR FORCE BASE

88TH ABW

OF

DESIGN CHIEF

DATEDRAWNDESIGNED CHECKED

RPR/RPL STEAM STANCHIONS

PROJECT NUMBER ZHTV 090018

SUBMITTAL - 100% GOVT. SUBMITTAL

SPR SPR MSS JUNE 2015

File details come from the government source that posted it. Updated .