5.2 B149C17MCCLayout.pdf

PDF 1 MB Posted

Attached to
77361 - FOM Cage with Installation
Solicitation number
FA857125Q0006
Issued by

About this file

This document appears to be a layout for the B149 C-17 Maintenance Control Center (MCC) at Robins Air Force Base in Georgia. The layout shows the planned placement of various rooms, equipment, and features for the MCC, including a break room, pharmacy, rest rooms, sprinkler controls, eye wash stations, personal lockers, and utility areas. The layout includes dimensions, gate/door locations, and requirements for fencing and shelving.

The related federal contract opportunity is for Solicitation Number FA857125Q0006, which is for providing a Facilitate Other Maintenance (FOM) Cage with installation at Building 149 for the Maintenance Support Group (AMXG) at Robins Air Force Base. The contractor will be required to provide all tools, parts, materials, equipment, transportation, and labor for this effort.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BREAK

ROOM

PHARMACY

REST RM.

RR.

RR

SPRINKLER

CONTROLS

EYE

WASH

STATION

EYE

WASH

STATION

MEN's

El ec t P nl

El ec t P nl

El ec t P nl

MEN

wmn

B149 C-17 MCC Layout

Supervisor Office

SupervisorSupervisor

Planning & Scheduling

Portable Eye Wash

Station

PSC

CMXG

CMXG

AMT

Office

U

TILITIES

H

AN

G

AR

C

EN

TER

LIN

E

IPV KITTING

INSPECTION

AND REPAIR

SHOP

25'-4"

32'

30'

26'-11"

20' SLIDING GATE

4'

STANDOFF

FROM

ELECTRICAL

REQUIRED

STANDOFF

FROM

ELECTRICAL

REQUIRED

STANDOFF

FROM

ELECTRICAL

REQUIRED

STANDOFF

FROM

ELECTRICAL

REQUIRED

4' 4'

4'

10' SLIDING GATE 10' SLIDING GATE

20' SLIDING GATE56'-6" 76'-6"

7'-10"7'-10"

25'-4"

20'-8" 20'-8"

7'-10"7'-10"

7'-10" 7'-10"

50'-1"

20'-8" 20'-8"

12' 10'

24'-6" 46'-6"

10' 10'

U

TILITIES

U

TILITIES

U

TILITIES

FENCING SHOWN IN GREEN

WITH TERMINAL POSTS IN

RED. APPROXIMATE RUNS

BETWEEN TERMINAL POSTS

ARE DIMENSIONED.

WILL RUN ON INSIDE

PERIMETER OF BLUE

WALKWAY BORDERING

HANGAR. APPROXIMATELY

700 LINEAR FEET OF

SHELVING TOTAL, 10 FEET

TALL.

THE (2) 20 FOOT GATES

SHOWN WILL BE OFFSET

FROM THE HANGAR

CENTERLINE AND ON THE

OUTSIDE OF THE FENCE

(RATHER THAN INSIDE).

ACCEPTABLE FOR THESE TO

CONSIST OF (2) 10' SLIDING

PANELS EACH.

THE 2 MAN DOORS WILL BE

LOCATED ACROSS FROM THE

DOOR TO THE SUPERVISOR

OFFICE AND ACROSS FROM

THE DOOR TO THE

BREAKROOM. LOCATIONS

SHOWN IN DRAWING ARE

APPROXIMATE.

32'-51 2"

15'-101 2"

15'-7"

6'-9"

36" MAN DOOR

36" MAN DOOR

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Bin24"x8"

AutoCAD SHX Text Bin24"x8"

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

BREAK

ROOM

PHARMACY

REST RM.

RR.

RR

SPRINKLER

CONTROLS

EYE

WASH

STATION

EYE

WASH

STATION

SHED

MEN's

El ec t P nl

El ec t P nl

El ec t P nl

EY

E

W

AS

H

EY

E W

AS

H

MEN

wmn

B149 C-17 MCC Layout

Supervisor Office

SupervisorSupervisor

Planning & Scheduling

Portable Eye Wash

Station

PSC

CMXG

CMXG

AMT

Office

U

TILITIES

H

AN

G

AR

C

EN

TER

LIN

E

IPV KITTING

INSPECTION

AND REPAIR

SHOP

20' SLIDING GATE

STANDOFF

FROM

ELECTRICAL

REQUIRED

STANDOFF

FROM

ELECTRICAL

REQUIRED

STANDOFF

FROM

ELECTRICAL

REQUIRED

STANDOFF

FROM

ELECTRICAL

REQUIRED

4' 4'

4'

10' SLIDING GATE 10' SLIDING GATE

FENCE (SHOWN IN GREEN) WILL RUN ON INSIDE PERIMETER OF BLUE WALKWAY

BORDERING HANGAR. APPROX 700' OF FENCING.

20' SLIDING GATE

U

TILITIES

U

TILITIES

U

TILITIES

12' AISLE

WIDTH

PHASE 1 SHELVING. USE

EXISTING (22) UPRIGHTS

AND 12' BEAMS TO

ASSEMBLE (17)

SHELVING UNITS WITH

SHELVES AT APPROX 4',

8', AND 12' HEIGHTS.

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Bin24"x8"

AutoCAD SHX Text Bin24"x8"

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

AutoCAD SHX Text Personal Locker

Sheets and Views
B149 C17 MCC Layout-Layout1
B149 C17 MCC Layout-Layout1 (2)

File details come from the government source that posted it. Updated .