Questions and Answers
FA8533-11-R-32740
13 February 2012
QUESTION #1 (Staircase & Maintenance Lift) Is it one (1) 1st article unit for each model developed or do both 1st article units for each model that need environmental testing performed.
Government Response: One (1) First Article unit for each model developed.
QUESTION #2 (Staircase & Maintenance Lift) Clarification on the number of manuals needed for this contract. Do we need to develop five manuals to support 3 articulating staircase units and 2 maintenance scissor stands, or is it a total of two manuals, combining the articulating staircase units into one manual and the maintenance scissor stands into the second?
Government Response: The Government’s requirement is for five (5) manuals - three (3) for the articulating staircase types and two (2) for the hydraulic scissor lift types.