DEPARTMENT OF THE AIR FORCE
HEADQUARTERS AIR FORCE MATERIEL COMMAND
WRIGHT-PATTERSON AIR FORCE BASE OHIO
19 December 2017
MEMORANDUM FOR AFSC/PZAAA
FROM: Johnny Mangum USAF AFMC AFLCMC/WIUED
SUBJECT: DC Generator PR 18-00164
Purpose is to identify potential sources of repair/overhaul for direct current generator used on US
Air Force TH-1H training helicopter; aircraft is a derivative of the legacy UH-1H “Huey”, and subject generator appeared on that aircraft and included with the TH-1H after conversion.
NOUN NSN P/N
Generator, Direct Current 6115-00-942-2094 30B37-37A
This requirement is for repair/overhaul services. Our services strategy is a five-year contract
(basic plus four option periods) and will continue through FY22. The projected quantities will be
Best Estimated Quantities (BEQ) of 4 per year. BEQ for the basic year is 15ea.
Generator; PN 30B37-37A, configuration and performance is IAW MIL-G-6162. Generator is used to generate the electrical power for 28-Volt aircraft electrical systems. This DC generator is a brush type rotating machine capable of delivering 30 Volts DC at rated current of 300 amperes, when driven at its rated speed (5000 rpm). The unit is self-cooled by means of an integral fan rotating with the output shaft. A terminal board is mounted on the housing to facilitate external connections. Slotted mounting holes are provided for ease of installation to aircraft engine.
Leading particulars for Generator; 30B37-37A:
ITEM Characteristic
Rated Voltage 30 Vdc
Rated Current 300 Amp
Rated Speed 5000 RPM
Minimum Speed for Regulation 5000 RPM
Maximum Speed for Regulation 10,000 RPM
Cooling Air 40ºC (Max)
Weight 47 lb (Max)
Diameter (Housing) 6-9/16 in
Length (Housing) 11-54/64 in
Output Spline 16 Teeth
Mounting Bolt Circle Diameter 5.000 in
No. of Mounting Slots 6
Rotation (Viewing Drive End) Counterclockwise
Deliver and Support Agile War-Winning Capabilities
DC Generator; Exploded View (Details omitted)
Index Description Index Description
Generator, Direct Current
1. Cover, Terminal Block 25. Washer
2. Nut 26. Screw
3. Washer 27. Washer
4. Washer 28. Washer
Cover Assembly ---*---
5. Nut 29. Terminal
6. Screw 30. Nipple
7. Cover 31. Capacitor, Subassy
8. Brush 32. Retainer
9. Screw 33. Screw
10. Washer ---*---
11. Washer 34. Bushing
---*--- 35. Pin
12. Cover Assy, End Bell 36. Ring
13. Bolt 37. Slinger, Dirt
14. Washer 38. End Bell Assy
15. Washer 39. Bearing, Ball
---*--- 40. Retainer
16. Nut 41. Ring
17. Washer 42. Slinger, Dirt
18. Spring 43. Bearing Ball
19. Fan 44. Retainer
20. Cap 45. Armature Assy
21. Shaft Assy, Drive 46. Plate, ID
22. Plate, Front 47. Screw
Capacitor Assy ---*---
23. Screw 48. Stator
24. Washer
Tools and Equipment or equivalent (respondent will list and explain tools and equipment to be used for inspection, repair/overhaul and testing) expected to accomplish repair/overhaul of DC generator would include balancing machine for armature assembly, dial indicating gage for measuring spring compression and to check for fit and clearance for components and subassemblies, capacitance bridge to verify capacitance values, insulation breakdown test set to verify proper clearances and isolation of components, electrical test set to verify performance and operation of the completed item, steam dispenser to remove dispelled material during prior operation; special tools expected would include spring scale, shaft wrench, brush spring hook and puller and aligner, bearing puller, any assembly or subassembly holding fixture or test stand.
With any solicitation, it is expected for the prospective supplier to offer their business information;
Company/Institute Name:
Address:
Point of Contact:
CAGE Code:
Phone Number:
E-mail Address:
Web Page URL:
Size of business pursuant to North American Industry Classification System (NAICS) Code:
Based on the NAICS Code(s), state whether company is considered:
Small Business (Yes / No)
Woman Owned Small Business (Yes / No)
Small Disadvantaged Business (Yes / No)
8(a) Certified (Yes / No)
HUBZone Certified (Yes / No)
Veteran Owned Small Business (Yes / No)
Service Disabled Veteran Small Business (Yes / No)
Central Contractor Registration (CCR). (Yes / No)
A statement as to whether your company is domestically or foreign owned (if foreign, please indicate the country of ownership).
Regarding capabilities; respond to the following general questions:
1. Describe briefly the capabilities of facility and nature of the goods and/or services provided. Include a description of staff composition and management structure.
2. Describe company's past experience on previous projects similar in complexity to this requirement. Include contract numbers, a brief description of the work performed, period of performance, agency/organization supported, and individual point of contact (Contracting Officer or Program Manager).
3. Describe company’s experience in repair/overhaul the Part Number/NSN listed.
4. Describe company's capabilities and experience in interpreting technical data, engineering drawings and manuals.
5. What is company’s current maximum repair/overhaul capacity per month? Provide information on any facility reserves you may possess to increase repair/overhaul capacity in the event of an immediate need do to critical operational mission requirements.
6. What quality assurance processes and test qualification practices does company employ? Provide a description of your quality program (ex. ISO 9001, AS9100, etc.).
Specific to the repair/overhaul of the Part Number/NSN listed; respond to the following questions.
1. Describe capabilities and experience in modifying any existing systems/equipment (hardware and software) to solve maintenance and support problems encountered during the repair/overhaul process.
2. Describe capabilities and experience in developing/modifying/interpreting test, evaluation, and repair/overhaul maintenance procedures.
3. Demonstrate ability and experience in repair/overhaul of the same or similar components, which are currently in use on commercial or military aircraft by providing the following information on the same or similar items:
a) Contract Number
b) Procuring Agency
c) Contract Value
d) Number of assets shipped
4. Provide any commercial manual(s) or Acceptance Test Procedures (ATP) and rights or access to these manuals and or ATP used for repair/overhaul and functional check of these assets.
5. Describe configuration management processes and how you identify and resolve parts obsolescence and diminishing manufacturing sources problems?
6. Discuss process for addressing any form, fit, and or function issues that may arise out of this effort.
7. Describe process for maintaining inventory records and reporting on hand/work-in-process balances and repair/overhaul status to customer.
8. Include a detailed listing of facilities and equipment, including quantities, required to satisfy the requirements of this effort.
1. Provide an outline of the proposed process, including inspections.
i. State the type of test procedures are anticipated for this effort.
ii. State the type of inspection processes anticipated for this effort.
1. NDI/T (specify inspection type and expected results).
If pre-existing technical information is available and in use to accomplish inspection, repair/overhaul, and testing of the Part number/NSN listed, providing GOV traceable document number and description will suffice.
9. How will organization address the absence of drawings, specifications, technical data, test procedures, etc. to satisfy the requirement.
Regarding Commerciality; respond to the following questions.
1. Is there established catalog or market price for this repair/overhaul?
2. If you offer this product and/or service to both U.S. Government and commercial sources, is the same workforce used for both the U.S. Government and general public?
3. Is this repair/overhaul offered to both under similar terms and conditions? Briefly describe any differences.
4. Describe your standard warranty and return process for goods and services furnished to the government for items similar in nature to this repair/overhaul.
Signed:
MANGUM.JOHNNY.R.12 Digitally signed by
93864140
MANGUM.JOHNNY.R.1293864140
Date: 2017.12.21 09:49:34 -05'00'
Johnny R Mangum
Electronics Engineer
USAF AFMC AFLCMC/WIUED
File details come from the government source that posted it.