This Engineering Data Requirements document (Attachment "A") provides detailed manufacturing specifications for a Data Display with Part Number 10-01128-06 and National Stock Number 5895-01-181-1224WF. The document outlines two primary technical requirements: 1) Item Unique Identifier (IUID) marking specifications, which mandate specific labeling practices including human and machine-readable matrices with minimum lettering/square sizes, and 2) Enhanced Bonding requirements for the display set, which involves replacing all 128 exterior bonds with new gold wire. The gold wire replacement is justified by two technical reasons: gold's superior conductivity and its less brittle nature compared to the original aluminum wire, making it a more robust material for the application.

View the file

Other files

File Type Posted
DED PWS_ 6_Aug_2025.pdf PDF
DED_25R0014 Synopsis.pdf PDF
EI_011435443.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REV: ENGINEERING DATA REQUIREMENTS

(ATTACHMENT “A”)

NOTE: MILITARY SPECIFICATIONS / STANDARDS WILL NOT BE FURNISHED IN THE BID SET.

1. THE FOLLOWING INSTRUCTIONS ARE FURNISHED FOR THE MANUFACTURE OF:

DATA DISPLAY

2. PART NUMBER:

10-01128-06

3. NATIONAL STOCK NUMBER:

5895-01-181-1224WF

PREPARED BY:

JAKE WIDDISON

OFFICE SYMBOL:

DATE:

08/14/2025

HILL AFB FORM 462 Page 1 of 1

4. THE FOLLOWING SPECIFICATIONS/STANDARDS, ETC., WILL BE USED IN LIEU OF THE DATA INDICATED. THE

SUPERSEDED DATA WILL NOT BE FURNISHED UNLESS SO INDICATED.

5. THE SOURCES/MATERIALS IF LISTED ON THE SPECIFICATION, STANDARDS AND DRAWINGS ARE THE ONLY SOURCES/MATERIALS FOR THOSE ITEMS. ANY SUBSTITUTIONS SHALL HAVE PRIOR APPROVAL BY THE COGNIZANT OO-

ALC ENGINEERING ACTIVITY.

6. IUID (ITEM UNIQUE IDENTIFIER) REQUIREMENTS AND EXPECTATIONS WHICH THE CONTRACTOR MUST ENSURE ARE

COMPLIED WITH.

7. CONTRACTORS DRAWINGS SHALL BE CHANGED OR SUPPLEMENTED BY CONTRACTOR FOR IUID COMPLIANCE.

A. LABEL SHALL CONTAIN ALL DATA ON EXISTING LABEL, (IF EXISTING LABEL IS TO BE REPLACED), ONLY

DELETE EXISTING LABEL WITH GOVERNMENT ENGINEERING PERMISSION.

B. USE HRI (HUMAN READABLE) AND MACHINE READABLE MATRIX. (USAF NOT EQUIPED TO READ BARCODE).

C. IUID MATRIX NEEDS TO BE HIGHLY VISIBLE, IN A LOCATION EASILY ACCESSIBLE.

D. IUID MARKING MUST BE PERMANENT.

E. MIL-STD-130, ANSI/AIM BCII, ISO 15434, ISO 15415, AND ISO 15418

F. IUID MARKING SPECIFICATIONS.

1. MINIMUM 1/8 INCH LETTERING ON HUMAN READABLE TO INCLUDE:

A. CAGE (17V)

B. P/N (1P)

C. SERIAL NUMBER (IS)

2. MINIMUM 1/4 INCH SQUARE ON MACHINE READABLE 2D MATRIX -CONSTRUCT 2 - TO INCLUDE

A. CAGE (17V)

B. P/N (1P)

C. SERIAL NUMBER (IS)

8. ENHANCED BONDING WILL BE PREFORMED ON DISPLAY, DATA ENTRY-DATA ENTRY DISPLAY SET.

A. ENHANCED BONDING REQUIRES THAT THE ENTIRE 128 EXTERIOR BONDS BE REPLACED WITH NEW GOLD WIRE RATHER THAN ONLY SPOT REPAIR OF CURRENT FAILED ROW AND COLUMN BONDS AS IN THE

PREVIOUS REPAIR PRACTICE.

B. THE ORIGINAL BOND WIRE WAS ALUMINUM RATHER THAN GOLD. GOLD WIRE IS REQUIRED FOR THIS

APPLICATION FOR TWO REASONS.

1. GOLD IS A BETTER CONDUCTOR THAN ALUMINUM.

2. GOLD IS LESS BRITTLE THAN ALUMINUM AND IS A MORE ROBUST MATERIAL FOR THIS

APPLICATION.