EI_011435443.pdf

PDF 100 KB Posted

Attached to
F-16 DED Head/Tray Repair
Solicitation number
FA825125R0014-Presolicitation
Issued by

About this file

This document is an Engineering Data Requirements form for a Display, Data Entry-Data Entry Display Set, with part number 16VE173003 and National Stock Number 5895-01-143-5443. The document outlines specific technical requirements for manufacturing the display set, with a focus on Item Unique Identifier (IUID) marking specifications and enhanced bonding processes. Key technical requirements include using human and machine-readable matrices for labeling, with minimum 1/8 inch lettering for human-readable and 1/4 inch square for machine-readable components. The enhanced bonding process mandates replacing all 128 exterior bonds with new gold wire, which is specified as superior to the original aluminum wire due to better conductivity and increased robustness. The document was prepared by Jake Widdison at Hill Air Force Base on 08/06/25, indicating this is a military-related engineering specification for a technical display component.

View the file

Other files

File Type Posted
DED PWS_ 6_Aug_2025.pdf PDF
DED_25R0014 Synopsis.pdf PDF
EI 5895-01-181-1224WF.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REV: ENGINEERING DATA REQUIREMENTS

(ATTACHMENT “A”)

NOTE: MILITARY SPECIFICATIONS / STANDARDS WILL NOT BE FURNISHED IN THE BID SET.

1. THE FOLLOWING INSTRUCTIONS ARE FURNISHED FOR THE MANUFACTURE OF:

DISPLAY, DATA ENTRY-DATA ENTRY DISPLAY SET

2. PART NUMBER:

16VE173003

3. NATIONAL STOCK NUMBER:

5895-01-143-5443

PREPARED BY:

Jake Widdison

OFFICE SYMBOL:

DATE:

08/06/25

HILL AFB FORM 462 Page 1 of 1

4. THE FOLLOWING SPECIFICATIONS/STANDARDS, ETC., WILL BE USED IN LIEU OF THE DATA INDICATED. THE

SUPERSEDED DATA WILL NOT BE FURNISHED UNLESS SO INDICATED.

5. THE SOURCES/MATERIALS IF LISTED ON THE SPECIFICATION, STANDARDS AND DRAWINGS ARE THE ONLY SOURCES/MATERIALS FOR THOSE ITEMS. ANY SUBSTITUTIONS SHALL HAVE PRIOR APPROVAL BY THE COGNIZANT

ENGINEERING ACTIVITY.

6. IUID (ITEM UNIQUE IDENTIFIER) REQUIREMENTS AND EXPECTATIONS WHICH THE CONTRACTOR MUST ENSURE ARE

COMPLIED WITH.

7. CONTRACTORS DRAWINGS SHALL BE CHANGED OR SUPPLEMENTED BY CONTRACTOR FOR IUID COMPLIANCE.

A. LABEL SHALL CONTAIN ALL DATA ON EXISTING LABEL, (IF EXISTING LABEL IS TO BE REPLACED), ONLY

DELETE EXISTING LABEL WITH GOVERNMENT ENGINEERING PERMISSION.

B. USE HRI (HUMAN READABLE) AND MACHINE READABLE MATRIX. (USAF NOT EQUIPED TO READ BARCODE).

C. IUID MATRIX NEEDS TO BE HIGHLY VISIBLE, IN A LOCATION EASILY ACCESSIBLE.

D. IUID MARKING MUST BE PERMANENT.

E. MIL-STD-130, ANSI/AIM BCII, ISO 15434, ISO 15415, AND ISO 15418

F. IUID MARKING SPECIFICATIONS.

1. MINIMUM 1/8 INCH LETTERING ON HUMAN READABLE TO INCLUDE:

A. CAGE (17V)

B. P/N (1P)

C. SERIAL NUMBER (IS)

2. MINIMUM 1/4 INCH SQUARE ON MACHINE READABLE 2D MATRIX -CONSTRUCT 2 - TO INCLUDE

A. CAGE (17V)

B. P/N (1P)

C. SERIAL NUMBER (IS)

8. ENHANCED BONDING WILL BE PREFORMED ON DISPLAY, DATA ENTRY-DATA ENTRY DISPLAY SET.

A. ENHANCED BONDING REQUIRES THAT THE ENTIRE 128 EXTERIOR BONDS BE REPLACED WITH NEW GOLD WIRE RATHER THAN ONLY SPOT REPAIR OF CURRENT FAILED ROW AND COLUMN BONDS AS IN THE

PREVIOUS REPAIR PRACTICE.

B. THE ORIGINAL BOND WIRE WAS ALUMINUM RATHER THAN GOLD. GOLD WIRE IS REQUIRED FOR THIS

APPLICATION FOR TWO REASONS.

1. GOLD IS A BETTER CONDUCTOR THAN ALUMINUM.

2. GOLD IS LESS BRITTLE THAN ALUMINUM AND IS A MORE ROBUST MATERIAL FOR THIS

APPLICATION.