Purge Fluid SOW PDF.pdf
PDF 113 KB Posted
- Attached to
- Purge Fluid - Hill, AFB Utah
- Solicitation number
- FA822425272KH
About this file
This document is a Purchase Specification issued by the 309 Aircraft Maintenance Group for Purge Fluid procurement. The specification requires the delivery of 15,000 gallons (+/- tolerance) of Purge Fluid that must conform to MIL-PRF-38299E military specification, specifically Part Number M38299 from Table 1. Delivery will be to Gage Watts at Buildings 236 & 680, 5875 Southgate Ave, Hill Air Force Base, Utah 84056, with a delivery timeline of 3 weeks after receipt of order.
Strict delivery and transportation requirements are outlined, including shipping only in a semi-tanker trailer, providing a Certificate of Conformance, Bill of Lading, and Safety Data Sheet. Delivery is restricted to Monday-Thursday between 0600-1300 Mountain Daylight Time, with each truck arriving at least 24 hours apart. Drivers must have a valid REAL Driver's License, speak and understand English, and pass a security check. Additional requirements include specific off-loading equipment such as 2-inch and 3-inch cam-lock fittings, a 20-foot approved fuel/purge fluid hose, and the ability to pump fluid independently if the base's holding tank pump is inoperable. The government point of contact is Gage Watts or Phil Benstog, and entry to the base will be through I-15 at Exit 338 Roy, UT.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Purge Fluid MIL-PRF-38299E.pdf | ||
| Req_15031_84400_15031 _Purge Fluid SOW 16 Sep 2025.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
309 Aircraft Maintenance Group
Purchase Specification
PURGE FLUID
16 Sep 2025
#15031
1. The Contractor shall deliver 15,000 gallons +/- of Purge Fluid that shall conform to Mil-
Spec: MIL-PRF-38299E.
a. Part Number M38299 (Must be specific to Table 1 found in MIL-PRF-38299E pages 5-6).
2. No recycling is required for this shipment.
3. Equipment required for off-loading Purge Fluid into 309 AMXG’s holding tank(s):
1. 2-inch and 3-inch cam-lock quick connect/disconnect pipefitting, compatible with the 309 AMXG holding tank(s) and system(s).
2. Minimum 20-feet of 3-inch approved fuel/purge fluid hose with 2-inch and 3-inch
Camlock fittings.
3. As an alternative, tanker shall have the ability to pump from tanker through its own pump into AMXG’s holding tanks in case the 309th AMXG holding tank’s pump is in-operable (INOP).
4. Driver must contact Government POC to provide Driver's License info to be sponsored on base through the Truck Gate the day before arrival to Hill AFB, Utah.
5. Contractor/Transportation Agent shell be escorted into 309 AMXG Facilities at all time.
4. Acquisition Requirements:
a. Purge Fluid must be shipped in a semi-tanker trailer (no drums or small containers)
b. The following shall be provided:
i. Certificate of Conformance (COC)
ii. Bill of Lading
iii. Safety Data Sheet (SDS)
c. Delivery location(s):
i. Gage Watts Buildings 236 & 680 5875 Southgate Ave
HAFB, UT 84056
d. Government POC:
i. Gage Watts (801) 499-9630 or Phil Benstog (385) 358-0491
e. Delivery: 3 Weeks ARO
f. Delivery times: Monday – Thursday 0600 to NLT 1300 (6am to 1pm Mountain Daylight Time.)
g. Each truck must arrive at least 24 hours apart from one another
h. Entry point: I-15 at Exit 338 Roy, UT (HAFB Gate)
i. Driver shall have valid REAL Driver License, ability to speak and understand
English, and ability to pass a security check.