Price_List.docx

DOCX document 13 KB Posted

Attached to
B809 Radiator Repair Services
Solicitation number
FA8224-18-Q-0214
Issued by

View the file

Other files

File Type Posted
Performance_Work_Statement.pdf PDF
Sole_Source_Justification.pdf PDF
CDRL_A001.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Inspect Radiator

Remove both tanks, sidewalls, and old solder. Bead-blast all hardware to bare metal.

Inspect to determine if radiator requires rebuild, re-core, or is non-repairable.

After inspection, if the contractor determines additional repairs are needed (that were not previously requested by the Government), the contractor shall notify 526 EMXS/MXDPB cardholder for approval prior to making additional repairs. In addition, the Government will determine if parts are beyond economical repair

B809 Radiator (Rebuild)

Remove both tanks, sidewalls, and old solder. Bead-blast all hardware to bare metal.

Rod out all tubes in core to remove contaminants and plugging. Flush core after rod out is complete.

Remove all old solder at the tube to header joint using header torch.

Clean core with ultrasonic, heat, and flux.

Re-solder all tube to header joints by hand.

Re-solder tanks and sidewalls on core.

Air test at 20 PSI for approximately 30 minutes to ensure there are no leaks.

Air dry and paint final assembly with heat resistant paint.

B809 Radiator (Re-Core)

Remove both tanks, sidewalls, and old solder. Bead-blast all hardware to bare metal.

Re-solder tanks and sidewalls on core. (The core dimensions should be 25 3/16" x 21 3/4" x 2 5/8" heavy duty 4 row, 12 fins per inch.)

Air test at 20 PSI for approximately 30 minutes to ensure there are no leaks.

Air dry and paint final assembly with heat resistant paint.