Questions Group V.docx
DOCX document 10 KB Posted
- Attached to
- Gantry System
- Solicitation number
- FA8224-10-R-0039
About this file
Questions and Answers Group V
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 3.doc | DOC document | |
| Final Amended Gantry1-PSD-20July10.doc | DOC document | |
| Amendment 2.doc | DOC document | |
| Questions Group VI.docx | DOCX document | |
| Questions Group IV.docx | DOCX document | |
| Questions Group III.docx | DOCX document | |
| Questions Group II.docx | DOCX document | |
| Amendment 1.doc | DOC document | |
| Final Purchase Spec Dated 25 May 2010 Amendment 0001.doc | DOC document | |
| Question Group.docx | DOCX document | |
| Solicitation FA8224-10-R-0039.doc | DOC document | |
| Purchase Spec Posted to Internet.pdf | ||
| 1423's.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions and Answers Group V Q1.
The spec refers to multiple 25 lb payload. Is it correct that the EE would carry only one payload at a time?
Answer: There will be one payload per system side (right and left).
Q2. Could you provide the approximate dimensions of the payloads?
Answer: Not needed.
Q3. Is the payload to be gripped automatically by the gantry and are the controls for such part of the Gantry control system?
Answer: No - Not a pick and place system - permanently attached.
Q4. The spec refers to Isolation of the Gantry. Is this an electrical or mechanical isolation?
Answer: Electrical.
Q5. Are door interlocks required?
Answer: No door interlocks are required to interface with chamber door opening and closing. Door interlocks are required for enclosure housing and gantry control components.