Contractor Name
CAGE code
PR No. FD2020-
Date Contract Awarded
Final Delivery Date (FDD)
Program Name
DODIC
Part Number
The contractor, at a minimum, shall allow DCMA to inspect the following points:
Mandatory - M: Stamp and/ or Signature on original documentation (i.e., Mfg. Planning, ATP, FAT Report, etc.)
Witness - W: GSI required to attend per comment section.
Verification - V: Stamp and/or Signature required unless noted otherwise (may be done by written verification) Monitor - R: Will monitor testing, may reduce to verification per comment section.
Notify - N: By phone or email prior to action.
Additional requirements: (DCMA reserves the right to impose additional inspection points as deemed necessary.)
Prepared by:
Date
THIS PLANNING SHEET WILL BE UPDATED IF NECESSARY.
QUALITY ASSURANCE LETTER OF INSTRUCTION
Planning Requirements
COMMENTS
NOTICE
Engineer Signature
Rev Date: 5 May 2019
Sheet1
Text46: 04JUNE2021
2021-06-04T11:36:55-0600
KELLY.ZACHARY.ANDREW.1596765501
undefined_9: N
Text32: 9. Additional Requirements undefined_8: M
Text31: 8. Shippers (DD250, Reports) undefined_7: M
Text30: 7. AMMO Data Card Review undefined_6: V
Text29: 6. Preparation for Shipment undefined_5: W
Text28: 5. LAT undefined_4: V
Text27: 4. LAT Sample Selection undefined_3: V
Text26: 3. X-Ray/N-Ray undefined_2: V
Text25: 2. Leak Test undefined: V
Text36: 1. Explosive Weight
2. Verify gross leak and fine leak check are performed.
3. Ensure film labeling correct. Ensure radiographic film is readable and well-defined. DCMA is not required to interpret film.
4. Randomly select LAT units per latest government approved ATP.
5. Testing should occur in accordance with latest government approved ATP. Prior to LAT ensure proper calibration and validation of all test equipment. Witness proper test setup and at least the first 3 functional tests. Further witnessing may be required if there are known concerns with the item or requested by Government Engineer.
6. Ensure Paperwork is correct.
7. Verify all energetic materials: list original manufacturer,original lot number, and latest certification/recertification date < 24 months.
8. Ensure Paperwork is correct. Verify Packaging, Packing, Preservation & Marking (PPP&M)
9. Any additional requirements imposed by DCMA shall be approved by Government Project Engineer
Text24: 1.Inspection
Part Number: 816949-4, 816948-4
DODIC: SR67, SR68
Text20:
Text19:
Part Number Line 2:
Contract No: 21-52200
Date Contract Awarded:
Final Delivery Date FDD:
Program Name:
Mandatory - M: Stamp and/ or Signature on original documentation (i.e., Mfg. Planning, ATP, FAT Report, etc.)
Verification - V: Stamp and/or Signature required unless noted otherwise (may be done by written verification)
Additional requirements: (DCMA reserves the right to impose additional inspection points as deemed necessary.)
Sheet1
Text46: 04JUNE2021
2021-06-04T11:33:51-0600
KELLY.ZACHARY.ANDREW.1596765501
undefined_9: N
Text32: 9. Additional Requirements undefined_8: M
Text31: 8. Shippers (DD250, Reports) undefined_7: M
Text30: 7. AMMO Data Card Review undefined_6: V
Text29: 6. Preparation for Shipment undefined_5: W
Text28: 5. LAT undefined_4: V
Text27: 4. LAT Sample Selection undefined_3: V
Text26: 3. X-Ray/N-Ray undefined_2: V
Text25: 2. Leak Test undefined: V
Text36: 1. Explosive Weight
2. Verify gross leak and fine leak check are performed.
3. Ensure film labeling correct. Ensure radiographic film is readable and well-defined. DCMA is not required to interpret film.
4. Randomly select LAT units per latest government approved ATP.
5. Testing should occur in accordance with latest government approved ATP. Prior to LAT ensure proper calibration and validation of all test equipment. Witness proper test setup and at least the first 3 functional tests. Further witnessing may be required if there are known concerns with the item or requested by Government Engineer.
6. Ensure Paperwork is correct.
7. Verify all energetic materials: list original manufacturer,original lot number, and latest certification/recertification date < 24 months.
8. Ensure Paperwork is correct. Verify Packaging, Packing, Preservation & Marking (PPP&M)
9. Any additional requirements imposed by DCMA shall be approved by Government Project Engineer
Text24: 1.Inspection
Part Number: 817141-3, 816951-5, 816952-1
DODIC: MT93, MT92, MT10
Text20:
Text19:
Part Number Line 2:
Contract No: 21-52200
Date Contract Awarded:
Final Delivery Date FDD:
Program Name:
DCMA QAR Reviewer
Date Review Completed
Date Issued to Contractor
The contractor is required to impose the listed below DCMA Inspection Points into the appropriate Work Orders.
All Work Orders pertaining to CRITICAL FLIGHT ITEMS must be identified on folders.
Mandatory - M: Stamp and/ or Signature on original documentation (i.e., Mfg. Planning, ATP, FAT Report, etc.)
Witness - W: GSI required to attend, may reduce level of effort after 50% of production lots found acceptable
Verification - V: Stamp and/or Signature required unless noted otherwise (may be done by written verification)
Monitor - R: Will monitor testing, may reduce to verification
Notify - N: By phone or email
Additional requirements: (DCMA reserves the right to impose additional inspection points as deemed necessary.)
Concurrence Signature by QAR/DCMA:
QAR/DCMA
Engineer
Sheet1
Contract No: 21-52200
Date Contract Awarded:
Final Delivery Date FDD:
Program Name: C-17
DODIC: WB40, WB41, WB44, WB46
undefined: V undefined_2: V undefined_3: V undefined_4: M undefined_5: W undefined_6: V undefined_7: V undefined_8: V undefined_9: N undefined_10:
undefined_11:
undefined_12:
Text19: PSEMC
Text20: 06331
Text21:
Text22:
Text23:
Text24: 1.Inspection
Text25: 2. Leak Test
Text26: 3. X-Ray/N-Ray
Text27: 4. LAT Sample Selection
Text28: 5. LAT
Text29: 6. Preparation for Shipment
Text30: 7. AMMO Data Card Review
Text31: 8. Shippers (DD250, DD1149, Reports)
Text32: 9. Additional Requirements
Text33:
Text34:
Text35:
Text36: 1. Verify that the Explosive Weight is identified and meets drawing and hazard classification requirements.
2. Verify gross/fine leak checks are performed per ATP requirements
3. Ensure film labeling correct. Ensure radiographic film readable / well-defined. DCMA not required to interpret film.
4. Randomly select LAT units per latest government approved ATP.
5. Prior to LAT ensure proper calibration and validation of all test equipment. Testing should occur in accordance with latest government approved ATP.
6. Ensure Paperwork is correct.
7. Verify all energetic materials: list original manufacturer, original lot no., and latest certification/recertification date < 24 months.
8. Ensure Paperwork is correct. Verify Packaging, Packing, Preservation & Marking (PPP&M)
9. Notify and obtain approval from the Project Engineer for any additional requirements imposed by DCMA.
2021-05-26T13:24:23-0600
TANNER.MATTHEW.W.1379435919
Text46: 2021-05-26
Text49:
Type name_1:
Type name_4:
Part Number:
Noun: 827843-02, 827844-01, 827844-02, 827843-01
The contractor is required to impose the listed below DCMA Inspection Points into the appropriate Work Orders.
Mandatory - M: Stamp and/ or Signature on original documentation (i.e., Mfg. Planning, ATP, FAT Report, etc.)
Witness - W: GSI required to attend, may reduce level of effort after 50% of production lots found acceptable
Verification - V: Stamp and/or Signature required unless noted otherwise (may be done by written verification)
Additional requirements: (DCMA reserves the right to impose additional inspection points as deemed necessary.)
Sheet1
Contract No: 21-52200
Date Contract Awarded:
Final Delivery Date FDD:
Program Name: C-17
DODIC: SR82
undefined: V undefined_2: V undefined_3: V undefined_4: M undefined_5: W undefined_6: V undefined_7: V undefined_8: V undefined_9: N undefined_10:
undefined_11:
undefined_12:
Text19: PSEMC
Text20: 06331
Text21:
Text22:
Text23:
Text24: 1.Inspection
Text25: 2. Leak Test
Text26: 3. X-Ray/N-Ray
Text27: 4. LAT Sample Selection
Text28: 5. LAT
Text29: 6. Preparation for Shipment
Text30: 7. AMMO Data Card Review
Text31: 8. Shippers (DD250, DD1149, Reports)
Text32: 9. Additional Requirements
Text33:
Text34:
Text35:
Text36: 1. Verify that the Explosive Weight is identified and meets drawing and hazard classification requirements.
2. Verify gross/fine leak checks are performed per ATP requirements
3. Ensure film labeling correct. Ensure radiographic film readable / well-defined. DCMA not required to interpret film.
4. Randomly select LAT units per latest government approved ATP.
5. Prior to LAT ensure proper calibration and validation of all test equipment. Testing should occur in accordance with latest government approved ATP.
6. Ensure Paperwork is correct.
7. Verify all energetic materials: list original manufacturer, original lot no., and latest certification/recertification date < 24 months.
8. Ensure Paperwork is correct. Verify Packaging, Packing, Preservation & Marking (PPP&M)
9. Notify and obtain approval from the Project Engineer for any additional requirements imposed by DCMA.
2021-05-26T13:31:25-0600
TANNER.MATTHEW.W.1379435919
Text46: 2021-05-26
Text49:
Type name_1:
Type name_4:
Part Number:
Noun: 824036-02
The contractor is required to impose the listed below DCMA Inspection Points into the appropriate Work Orders.
Mandatory - M: Stamp and/ or Signature on original documentation (i.e., Mfg. Planning, ATP, FAT Report, etc.)
Witness - W: GSI required to attend, may reduce level of effort after 50% of production lots found acceptable
Verification - V: Stamp and/or Signature required unless noted otherwise (may be done by written verification)
Additional requirements: (DCMA reserves the right to impose additional inspection points as deemed necessary.)
Sheet1
Contract No: 21-52200
Date Contract Awarded:
Final Delivery Date FDD:
Program Name: C-17
DODIC: JM45 (SHIP SET); VARIOUS (INDIVIDUAL LINES)
undefined: V undefined_2: V undefined_3: V undefined_4: M undefined_5: W undefined_6: V undefined_7: V undefined_8: V undefined_9: N undefined_10:
undefined_11:
undefined_12:
Text19: PSEMC
Text20: 06331
Text21:
Text22:
Text23:
Text24: 1.Inspection
Text25: 2. Leak Test
Text26: 3. X-Ray/N-Ray
Text27: 4. LAT Sample Selection
Text28: 5. LAT
Text29: 6. Preparation for Shipment
Text30: 7. AMMO Data Card Review
Text31: 8. Shippers (DD250, DD1149, Reports)
Text32: 9. Additional Requirements
Text33:
Text34:
Text35:
Text36: 1. Verify that the Explosive Weight is identified and meets drawing and hazard classification requirements.
2. Verify gross/fine leak checks are performed per ATP requirements
3. Ensure film labeling correct. Ensure radiographic film readable / well-defined. DCMA not required to interpret film.
4. Randomly select LAT units per latest government approved ATP.
5. Prior to LAT ensure proper calibration and validation of all test equipment. Testing should occur in accordance with latest government approved ATP.
6. Ensure Paperwork is correct.
7. Verify all energetic materials: list original manufacturer, original lot no., and latest certification/recertification date < 24 months.
8. Ensure Paperwork is correct. Verify Packaging, Packing, Preservation & Marking (PPP&M)
9. Notify and obtain approval from the Project Engineer for any additional requirements imposed by DCMA.
2021-05-26T13:27:06-0600
TANNER.MATTHEW.W.1379435919
Text46: 2021-05-26
Text49:
Type name_1:
Type name_4:
Part Number:
Noun: 9510382-30 (SHIP SET); 824341-XX (INDIVIDUAL LINES)
Mandatory - M: Stamp and/ or Signature on original documentation (i.e., Mfg. Planning, ATP, FAT Report, etc.)
Verification - V: Stamp and/or Signature required unless noted otherwise (may be done by written verification)
Additional requirements: (DCMA reserves the right to impose additional inspection points as deemed necessary.)
Sheet1
Text46: 27 May 2021
2021-05-27T14:38:43-0600
KRAMER.LAWRENCE.C.1141472808
undefined_9: N
Text32: 9. Additional Requirements undefined_8: M
Text31: 8. Shippers (DD250, Reports) undefined_7: M
Text30: 7. AMMO Data Card Review undefined_6: V
Text29: 6. Preparation for Shipment undefined_5: W
Text28: 5. LAT undefined_4: V
Text27: 4. LAT Sample Selection undefined_3: V
Text26: 3. X-Ray/N-Ray undefined_2: V
Text25: 2. Leak Test undefined: V
Text36: 1. Explosive Weight
2. Verify gross leak and fine leak check are performed.
3. Ensure film labeling correct. Ensure radiographic film is readable and well-defined. DCMA is not required to interpret film.
4. Randomly select LAT units per latest government approved ATP.
5. Testing should occur in accordance with latest government approved ATP. Prior to LAT ensure proper calibration and validation of all test equipment. Witness proper test setup and at least the first 3 functional tests. Further witnessing may be required if there are known concerns with the item or requested by Government Engineer.
6. Ensure Paperwork is correct.
7. Verify all energetic materials: list original manufacturer,original lot number, and latest certification/recertification date < 24 months.
8. Ensure Paperwork is correct. Verify Packaging, Packing, Preservation & Marking (PPP&M)
9. Any additional requirements imposed by DCMA shall be approved by Government Project Engineer
Text24: 1.Inspection
Part Number: 826812-2, 826812-1, 826813-1, 826808-1, 837400-01, 837410-01
DODIC: DWFI, DWFH, JL53, JL46, JN53, JN54
Text20: 06331
Text19: PSEMC
Part Number Line 2:
Contract No:
Date Contract Awarded:
Final Delivery Date FDD:
Program Name: T-6 CFIS
Mandatory - M: Stamp and/ or Signature on original documentation (i.e., Mfg. Planning, ATP, FAT Report, etc.)
Verification - V: Stamp and/or Signature required unless noted otherwise (may be done by written verification)
Additional requirements: (DCMA reserves the right to impose additional inspection points as deemed necessary.)
Sheet1
Text46: 27 May 2021
2021-05-27T14:43:57-0600
KRAMER.LAWRENCE.C.1141472808
undefined_9: N
Text32: 9. Additional Requirements undefined_8: M
Text31: 8. Shippers (DD250, Reports) undefined_7: M
Text30: 7. AMMO Data Card Review undefined_6: V
Text29: 6. Preparation for Shipment undefined_5: W
Text28: 5. LAT undefined_4: V
Text27: 4. LAT Sample Selection undefined_3: V
Text26: 3. X-Ray/N-Ray undefined_2: V
Text25: 2. Leak Test undefined: V
Text36: 1. Explosive Weight
2. Verify gross leak and fine leak check are performed.
3. Ensure film labeling correct. Ensure radiographic film is readable and well-defined. DCMA is not required to interpret film.
4. Randomly select LAT units per latest government approved ATP.
5. Testing should occur in accordance with latest government approved ATP. Prior to LAT ensure proper calibration and validation of all test equipment. Witness proper test setup and at least the first 3 functional tests. Further witnessing may be required if there are known concerns with the item or requested by Government Engineer.
6. Ensure Paperwork is correct.
7. Verify all energetic materials: list original manufacturer,original lot number, and latest certification/recertification date < 24 months.
8. Ensure Paperwork is correct. Verify Packaging, Packing, Preservation & Marking (PPP&M)
9. Any additional requirements imposed by DCMA shall be approved by Government Project Engineer
Text24: 1.Inspection
Part Number: 826810-3, 826810-4, 826814-5, 826814-8,826814-7, 826814-6
DODIC: JL48, JL47, JL51, JL49, JL50
Text20: 06331
Text19: PSEMC
Part Number Line 2:
Contract No:
Date Contract Awarded:
Final Delivery Date FDD:
Program Name: T-6 MDC and SMDC