Question 6

Based on the previous question responses, why is a 1 millisecond sample rate on a system that only preloads?

a. After further review the 1 millisecond is for Lot Acceptance Testing and Qualification Testing.

The Activation and Conditioning system should have a sample rate adequate for verifying the health and status of the battery. Manufacturer should recommend appropriate sample rate and provide justification.