Item_Price_List_-_Energy_Management_Control_Systems.xlsx
XLSX spreadsheet 22 KB Posted
- Attached to
- Energy Management Control Systems (EMCS) Federal contract opportunity
- Solicitation number
- FA8201-14-R-0016
About this file
Item Price List for required Energy Management and Control Systems supplies incidental installation and repairs. Prospective contractors are to complete all unit and total prices for each item and year based on government quantity estimates. Estimates are not a guarantee of actual quantities or use and do not obligate the government to procure any items repairs or incidental services.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Statement_of_Work_(SOW)_EMCS_Final.docx | DOCX document | |
| Solicitation_-_Energy_Management_Control_System.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLIN 0001 - Supplies & Inc. Ser
| CLIN | 11-Aug-2014 | Est Annual Qty | Year 1 | Year 2 | Year 3 | Year 4 | Year 5 | |||||
| 0001 | Description | Unit Price | Total Price | Unit Price | Total Price | Unit Price | Total Price | Unit Price | Total Price | Unit Price | Total Price |
| 1 | Multi-protocol communications interface controller complete with high-speed Ethernet port and three 485 and one RS485/RS232 ports, in small DIN rail mountable package | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 2 | DB9 adapter Card for using RS-232 communications. Includes Cable and card | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 3 | Universal Controller consisting of digital microprocessor unit with I/O. Includes: | |||||||||||
| 16 Universal Inputs (Software Configured Signal Conditioning) | ||||||||||||
| 8 Digital Outputs (Triac-24VAC) | ||||||||||||
| 8 analog outputs (software selectable 0-10v, 4-20mA) | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ | |
| 4 | Variable Air Volume (VAV) Controller. Includes: | |||||||||||
| Input/Output: Internal Velocity Pressure Sensor, 4 digital Outputs and 2 Analog Outputs (Heat/Damper), | ||||||||||||
| 2 Digital Inputs, and 4 Analog Inputs (see Cut sheet for I/O pre-assignments) | ||||||||||||
| Unit is housed in a plastic Tray and includes a Belimo 35"lb. 2-10 Vdc Damper Actuator | 150 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ | |
| 5 | Controller Enclosure for up to 2 MicroScan 5 UNV cards including AC power switch and fuses, 24 VAC Transformer for power, and a 24" w x 24" h NEMA 4 enclosure. | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 6 | Controller Enclosure for up to 4 MicroScan 5 UNV cards including AC power switch and fuses, 24 VAC Transformer for power, and a 24" w x 36" h NEMA 4 enclosure. | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 7 | NEMA 1 Enclosure/panel, 24hx20wx6d, with provisions for 1MS5-UNV. Includes AC Surge, 24 VAC power supply and DIN rail | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 8 | NEMA 1 Enclosure/panel, 36hx30wx6d, with provisions for up to 3 MS5-UNVs. Includes AC surge, 24 VAC power supply and DIN rail | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 9 | NEMA 1 Enclosure/panel, 20hx20wx6d, with Universal Controller. Also includes AC Surge, 24 VAC transformer and DIN rail | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 10 | NEMA 1 Enclosure/panel, 30hx24wx6d, with two Universal Controllers . Also includes AC Surge, 2 each 24 VAC transformers and DIN rail | 12 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 11 | 2 wire surge protector for communications for UNV panels | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 12 | AC surge protector | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 13 | NEMA 1 Enclosure | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 14 | NEMA 4 Enclosure | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 15 | NEMA 12 Enclosure | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 16 | Cat 6 Ethernet Patch Cable, 10' | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 17 | Adapter Card for using RS-232 communications. Includes Cable and card | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 18 | Single stage heat and cool applications (1H/1C), No local schedule/programming support, no Economizer | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 19 | Two stage heat and cooling applications (2H/2C), No local schedule/programming support, no Economizer | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 20 | Two stage heat and cooling applications (2H/2C), No local schedule/programming support, w/ Economizer | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 21 | Heat Pump, up to three stage heat and two cooling applications (3H/2C), No local schedule/programming support, no Economizer | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 22 | Heat Pump, up to three stage heat and two cooling applications (3H/2C), local schedule/programming support, no Economizer | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 23 | Heat Pump, up to three stage heat and two cooling applications (3H/2C), No local schedule/programming support, no Economizer with passive infra-red (PIR) occupancy sensor | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 24 | Two stage heat/single cool applications (2H/1C), Fan Control, Filter/Fan inputs, local override, no Economizer, digital (on/off) outputs | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 25 | Two stage heat/single cool applications (2H/1C), Fan Control, Filter/Fan inputs, local override, no Economizer, Analog (0-10V) outputs | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 26 | 1000 Ohm RTD, room stat set point adjustment input | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 27 | Single-Ended Voltage 0-5 VDC | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 28 | Loop Powered Current Transmitter 0-20 ma (240 OHM) | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 29 | Self Powered Current Transmitter 0-20 ma (240 OHM) | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 30 | Loop Powered Current Transmitter 0-20 ma (243 ohm) | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 31 | Self Powered Current Transmitter 0-20 ma (243 ohm) | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 32 | +24 Volt Power, 0-5 VDC input signal | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 33 | 0-10V Single-Ended Voltage Input | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 34 | +15 Volt Power, 0-5 VDC input signal | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 35 | Digital Input Module, required for any DI or Accumulator input channels | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 36 | 1000 ohm plat. RTD, override switch & set point adjustment | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 37 | Transmitter option for temperature input | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 38 | Portable terminal for local programming of devices. Includes notebook PC, communications converter, cable, users manual, and carrying case | 2 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 39 | Software only (no PC) | 4 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 40 | Controller with 6 AI, 4 DI and 8 DO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 41 | Controller with 6 AI, 4 DI, 6 DO and 2 AO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 42 | Controller with 6 AI, 4 DI, 8 DO and 4 AO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 43 | Controller with 4 AI, 2 DI, and 4 DO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 44 | Controller with 4 AI, 2 DI, 2 AO, and 4 DO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 45 | Controller with 3 AI, and 4 DO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 46 | Controller with 3 AI, 2 AO, and 4 DO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 47 | Processor card for up to 32 Controllers | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 48 | Motherboard for logic cards | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 49 | Installation - Multi-protocol communications interface controller complete with high-speed Ethernet port and three 485 and one RS485/RS232 ports, in small DIN rail mountable package | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 50 | Installation - DB9 adapter Card for using RS-232 communications. Includes Cable and card | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| Installation - Universal Controller consisting of digital microprocessor unit with I/O. Includes: | ||||||||||||
| 16 Universal Inputs (Software Configured Signal Conditioning) | ||||||||||||
| 8 Digital Outputs (Triac-24VAC) | ||||||||||||
| 51 | 8 analog outputs (software selectable 0-10v, 4-20mA) | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| Installation - Variable Air Volume (VAV) Controller. Includes: | ||||||||||||
| Input/Output: Internal Velocity Pressure Sensor, 4 digital Outputs and 2 Analog Outputs (Heat/Damper), | ||||||||||||
| 2 Digital Inputs, and 4 Analog Inputs (see Cut sheet for I/O pre-assignments) | ||||||||||||
| 52 | Unit is housed in a plastic Tray and includes a Belimo 35"lb. 2-10 Vdc Damper Actuator | 150 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 53 | Installation - Controller Enclosure for up to 2 MicroScan 5 UNV cards including AC power switch and fuses, 24 VAC Transformer for power, and a 24" w x 24" h NEMA 4 enclosure. | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 54 | Installation - Controller Enclosure for up to 4 MicroScan 5 UNV cards including AC power switch and fuses, 24 VAC Transformer for power, and a 24" w x 36" h NEMA 4 enclosure. | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 55 | Installation - NEMA 1 Enclosure/panel, 24hx20wx6d, with provisions for 1MS5-UNV. Includes AC Surge, 24 VAC power supply and DIN rail | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 56 | Installation - NEMA 1 Enclosure/panel, 36hx30wx6d, with provisions for up to 3 MS5-UNVs. Includes AC surge, 24 VAC power supply and DIN rail | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 57 | Installation - NEMA 1 Enclosure/panel, 20hx20wx6d, with Universal Controller. Also includes AC Surge, 24 VAC transformer and DIN rail | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 58 | Installation - NEMA 1 Enclosure/panel, 30hx24wx6d, with two Universal Controllers . Also includes AC Surge, 2 each 24 VAC transformers and DIN rail | 12 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 59 | Installation - 2 wire surge protector for communications for UNV panels | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 60 | Installation - AC surge protector | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 61 | Installation - NEMA 1 Enclosure | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 62 | Installation - NEMA 4 Enclosure | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 63 | Installation - NEMA 12 Enclosure | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 64 | Installation - Cat 6 Ethernet Patch Cable, 10' | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 65 | Installation - Adapter Card for using RS-232 communications. Includes Cable and card | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 66 | Installation - Single stage heat and cool applications (1H/1C), No local schedule/programming support, no Economizer | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 67 | Installation - Two stage heat and cooling applications (2H/2C), No local schedule/programming support, no Economizer | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 68 | Installation - Two stage heat and cooling applications (2H/2C), No local schedule/programming support, w/ Economizer | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 69 | Installation - Heat Pump, up to three stage heat and two cooling applications (3H/2C), No local schedule/programming support, no Economizer | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 70 | Installation - Heat Pump, up to three stage heat and two cooling applications (3H/2C), local schedule/programming support, no Economizer | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 71 | Installation - Heat Pump, up to three stage heat and two cooling applications (3H/2C), No local schedule/programming support, no Economizer with passive infra-red (PIR) occupancy sensor | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 72 | Installation - Two stage heat/single cool applications (2H/1C), Fan Control, Filter/Fan inputs, local override, no Economizer, digital (on/off) outputs | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 73 | Installation - Two stage heat/single cool applications (2H/1C), Fan Control, Filter/Fan inputs, local override, no Economizer, Analog (0-10V) outputs | 40 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 74 | Installation - 1000 Ohm RTD, room stat set point adjustment input | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 75 | Installation - Single-Ended Voltage 0-5 VDC | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 76 | Installation - Loop Powered Current Transmitter 0-20 ma (240 OHM) | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 77 | Installation - Self Powered Current Transmitter 0-20 ma (240 OHM) | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 78 | Installation - Loop Powered Current Transmitter 0-20 ma (243 ohm) | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 79 | Installation - Self Powered Current Transmitter 0-20 ma (243 ohm) | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 80 | Installation - '+24 Volt Power, 0-5 VDC input signal | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 81 | Installation - 0-10V Single-Ended Voltage Input | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 82 | Installation - '+15 Volt Power, 0-5 VDC input signal | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 83 | Installation - Digital Input Module, required for any DI or Accumulator input channels | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 84 | Installation - 1000 ohm plat. RTD, override switch & set point adjustment | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 85 | Installation - Transmitter option for temperature input | 50 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 86 | Installation - Controller with 6 AI, 4 DI and 8 DO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 87 | Installation - Controller with 6 AI, 4 DI, 6 DO and 2 AO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 88 | Installation - Controller with 6 AI, 4 DI, 8 DO and 4 AO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 89 | Installation - Controller with 4 AI, 2 DI, and 4 DO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 90 | Installation - Controller with 4 AI, 2 DI, 2 AO, and 4 DO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 91 | Installation - Controller with 3 AI, and 4 DO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 92 | Installation - Controller with 3 AI, 2 AO, and 4 DO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 93 | Installation - Processor card for up to 32 Controllers | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 94 | Installation - Motherboard for logic cards | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| CLIN | 11-Aug-2014 | Est Annual Qty | Year 1 | Year 2 | Year 3 | Year 4 | Year 5 | |||||
| 0002 | Description | Unit Price | Total Price | Unit Price | Total Price | Unit Price | Total Price | Unit Price | Total Price | Unit Price | Total Price |
| 1 | Repair - MS4- xTalk | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 2 | Repair - UNV (dni triac, relay or 232 board) | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 3 | Repair - Controller only, no actuator VAV/AO | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 4 | Repair - MS5-xTalk | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |
| 5 | Repair - MS-5 UNV | 30 | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ |