FA8126-21-Q-0009 PC4F Mobile Control Booth

Questions and Answers – 25 November 2020

No. Issue Description and/or Question/Recommendation

Government Response

1 Is the contractor to quote and supply the console, UPS, and racks?

No, we will ship those items to the contractor for installation into the cab

2 Will low profile 1” surface mounted LED lights suffice instead of recessed? (The wiring can still be above the ceiling)

No

3 The SoW states 20-gauge steel for the interior walls & ceiling, but the floor plan states 16 gauge.

Please clarify

The drawing package (floor plan) spec is the most current. The thicker metal is use for structural and acoustic reasons.

4 If there is cheaper and larger size booth solution available, can that be offered?

No, the size specification is a requirement based on the end user’s constraints and is not negotiable.