DEPARTMENT OF THE AIR FORCE

OKLAHOMA CITY AIR LOGISTICS COMPLEX (OC-ALC)

TINKER AIR FORCE BASE OKLAHOMA

Statement of Requirement / Item Description

C19-027 Formech 2440Vacuum Thermoforming Machine (Brand Name or Equal)

One (1) Vacuum Thermoforming Machine Specifications:

· Max Size (footprint): W x L x H, 12 ft. x 14 ft. x 15 ft.

· Minimum Forming Area: 45 in. x 65 in.

· Minimum Depth of Draw: 23 in.

· Plastic Clamping: Adjustable pneumatic and/or manual

· Tooling Table: Pneumatic or servo-electric driven

· Configuration: Single Station, Single Sheet

· Heaters: Energy efficient quartz

· Heater Controls: Multiple zones with variable adjustability

· Heater Movement: Servo-electric driven

· Pyrometer Control of heating cycle

· Recipe Profiles Minimum capability to store 40 profiles

· Cooling Fans

· Vacuum Reservoir

· Vacuum Pump

· Vacuum Regulator

· Air regulator and filter

· Operation: Manual and Semi-auto modes

· Adjustable times, speeds, and delays of equipment actions

· Emergency Stop

· Lockout Tag out of all sources of energy

· Controlled Pre-Stretch: Vacuum and/or compressed air

· Reducing window or adj. window 30 in. x 30 in.

· Spare parts kit

· Must not require a pit or other type of foundation work.

· Working height shall be less than 48 inches by design or through the use of contractor supplied work stand.

· Electrical: Shall function on 480V electric utilities and if a transformer is necessary the contractor shall supply as part of this Purchase Document. Electrical requirements shall be provided with the contractor’s bid to include transformer details if necessary.

· Air: Shall function on 100 psi shop air and if a regulator is necessary the contractor shall supply as part of this Purchase Document.

· Types of material: Plastic sheets i.e.: Lexan, Kydex, Royalite

· Material Thickness: up to 0.20 in.

· Pre-Stretch: Billow-vac or Snap-back

· Auto Level: Control sheet sag by air application

· Noise: Below 80dB (A)

· Delivery and Installation

· On-site Training

· Manuals and Warranty must be included image1.wmf