Statement of Requirement / Item Description
C19-027 Formech 2440Vacuum Thermoforming Machine (Brand Name or Equal)
One (1) Vacuum Thermoforming Machine Specifications:
· Max Size (footprint): W x L x H, 12 ft. x 14 ft. x 15 ft.
· Minimum Forming Area: 45 in. x 65 in.
· Minimum Depth of Draw: 23 in.
· Plastic Clamping: Adjustable pneumatic and/or manual
· Tooling Table: Pneumatic or servo-electric driven
· Configuration: Single Station, Single Sheet
· Heaters: Energy efficient quartz
· Heater Controls: Multiple zones with variable adjustability
· Heater Movement: Servo-electric driven
· Pyrometer Control of heating cycle
· Recipe Profiles Minimum capability to store 40 profiles
· Cooling Fans
· Vacuum Reservoir
· Vacuum Pump
· Vacuum Regulator
· Air regulator and filter
· Operation: Manual and Semi-auto modes
· Adjustable times, speeds, and delays of equipment actions
· Emergency Stop
· Lockout Tag out of all sources of energy
· Controlled Pre-Stretch: Vacuum and/or compressed air
· Reducing window or adj. window 30 in. x 30 in.
· Spare parts kit
· Must not require a pit or other type of foundation work.
· Working height shall be less than 48 inches by design or through the use of contractor supplied work stand.
· Electrical: Shall function on 480V electric utilities and if a transformer is necessary the contractor shall supply as part of this Purchase Document. Electrical requirements shall be provided with the contractor’s bid to include transformer details if necessary.
· Air: Shall function on 100 psi shop air and if a regulator is necessary the contractor shall supply as part of this Purchase Document.
· Types of material: Plastic sheets i.e.: Lexan, Kydex, Royalite
· Material Thickness: up to 0.20 in.
· Pre-Stretch: Billow-vac or Snap-back
· Auto Level: Control sheet sag by air application
· Noise: Below 80dB (A)
· Delivery and Installation
· On-site Training
· Manuals and Warranty must be included image1.wmf