DEPARTMENT OF THE AIR FORCE
OKLAHOMA CITY AIR LOGISTICS COMPLEX (OC-ALC)
TINKER AIR FORCE BASE OKLAHOMA
Commodity Item Description
Three (3) MultiRAE Six-Gas Monitor LEL meters (Model: PGM-6228) manufactured by RAE Systems. These will replace existing meters directly, to continue to be used with the RAE Systems AutoRAE 2 calibration equipment on hand.
• Shall be monitor part numbers: MBB3-A1C1E00-020 / GVMBB3-A1C1E00-020 / or model number PGM-6228 with the following sensors installed:
• Must have PID Sensor VOC 10.6 eV (HR), Range: 0.1 to 5,000 ppm, Resolution: 0.1 ppm
• Must have Combustible Sensor: Catalytic LEL, Range: 0 to 100% LEL, Resolution: 1%
LEL
• Must have Electrochemical Sensor: Oxygen (O2), Range: 0 to 30% Vol., Resolution:
0.1% Vol.
• Monitors must meet MIL-STD-810G and -461F compliant.
• Must have Rechargeable Li-ion extended duration batteries (18 hr. runtime) with alkaline battery adapters (4xAA batteries, 6 hr. runtime).
• Must have LCD display with real-time gas concentrations, PID gas measurement and correction, battery status.
• Must have built in pump for air sampling with average minimum flow rate of 250 cc/min and automatic shut off in low-flow conditions.
• Must meet IP-65 ingress protection rating for dust and water resistance.
• Must contains on-board gas libraries and continuous data logging.