This document is a Salient Characteristics specification for a portable wash rack procurement (Item 379 EMXS/ECES). The solicitation requires one (1) EMXS Portable Wash Rack with specific technical and operational requirements. The unit must include on and off ramps with pull-through capabilities featuring entry and exit doors on opposite ends to allow vehicles to pass through after washing. The wash rack must be wind-rated to withstand winds up to 25 meters per second, have water input capabilities, and include an oil-water separator system for environmental compliance. Electrical specifications require 240/415V at 50 hertz operation.
The portable wash rack must be at least 10 feet in width and rated to support loads of 16,000 pounds. Delivery is required to W62G2T, W1 AS DLA DIST SAN JOAQUIN, located at 25600 S Chrisman Road, Rec Whse 57, Tracy, CA 95304-5000. Following delivery, the equipment requires installation at Al Udeid Air Base, which includes site preparation, utility hookup, and testing services. The portability requirement indicates the unit must be capable of relocation while maintaining structural integrity and operational functionality.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Questions and Answers.docx | DOCX document | |
| Combo Synopsis Solicitation Wash Rack 19Feb26.pdf | ||
| Combo Synopsis Solicitation Wash Rack 19Feb26.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
EMXS Portable Wash Rack
379 EMXS/ ECES
• Item Description – Portable Wash Rack o Must include on and off ramp o Must include pull through capabilities - entry/exit doors on opposite ends so that the vehicle can pass through the wash rack after washing o Must be wind rated to withstand winds up to 25m/s o Must have inputs for water o Must catch and separate oil and water i.e. have a oil-water sperator o Needs to be 240/415V o 50 hertz o Must be at least 10 feet in width o Must be rated to support 16,000 lbs o Must be portable o Must be delivered to W62G2T
W1 AS DLA DIST SAN JOAQUIN
25600 S CHRISMAN ROAD, REC WHSE 57
TRACY, CA 95304-5000
o Will require installation at Al Udeid Air Base to include site prep, utility hookup, and testing
• Quantity o 1