Q A RPR BLDG 877 PART 2.docx
DOCX document 16 KB Posted
- Attached to
- Repair Roof Building 877 Commissary
- Solicitation number
- FA5685-12-R-0011
About this file
PART 2 OF QUESTIONS AND ANSWERS.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 00-10-1015RPR ROOF 877_updated dwg 2012_05.pdf | ||
| INC 1106 Forms Bldg No.877.pdf | ||
| LJYC101015-AFF 813 .pdf | ||
| Q A RPR BLDG 877.doc | DOC document | |
| RFP-FA5685-12-R-0011.doc | DOC document | |
| STATEMENT OF WORK-TEMP.doc | DOC document | |
| HAZMAT-ODC-EPA17.pdf | ||
| LJYC 10-1015 Final Specs.pdf | ||
| PPL_Feb_2012.xls | XLS spreadsheet | |
| Attachment 1- Specs.pdf | ||
| Attachment 3 - WAWF Instructions.doc | DOC document | |
| Attachment 5- Incirlik Instuctions.doc | DOC document | |
| FA5685-12-R-0011 REPAIR ROOF FAC. 877 COMMISSARY.doc | DOC document | |
| Attachment 2- LJYC 10-1015 INC-1101 - Untabulated.xlsx | XLSX spreadsheet | |
| Site Visit Reservation Form.doc | DOC document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
The following have been added by full text:
QUESTIONS & ANSWERS PART 2
FA5685-12-R-0011
RPR ROOF Bldg#877 Project No: LJYC 10-1015 Incirlik AB, Turkey Questions and Answers
Question #1
As far as the safety plan is concerned, does the government prefer a plan outlining the measures that the contractor is planning to take for safety while working on the roof, in terms of safety procedures or safety materials or both? In the event there are any additional measures that the contractor will be encouraged to take and will likewise list as part of the Safety Plan, please advise at your convenience.
Answer #1
Per the Engineer: The safety regulation is both the material and the use, or plan. Attached is the specifications for safety that the contractor should meet.
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN SOCIETY OF SAFETY ENGINEERS (ASSE/SAFE)
ASSE/SAFE A10.32 (2004) Fall Protection ASSE/SAFE A10.34 (2001; R 2005) Protection of the Public on or Adjacent to Construction Sites ASSE/SAFE Z359.1 (2007) Safety Requirements for Personal Fall Arrest Systems, Subsystems and Components
3.4.3 Fall Protection for Roofing Work
Implement fall protection controls based on the type of roof being constructed and work being performed. Evaluate the roof area to be accessed for its structural integrity including weight-bearing capabilities for the projected loading.
a. Low Sloped Roofs:
(1) For work within 6 feet of an edge, on low-slope roofs, Protect personnel from falling by use of personal fall arrest systems, guardrails, or safety nets. A safety monitoring system is not adequate fall protection and is not authorized.
(2) For work greater than 6 feet from an edge, erect and install warning lines in accordance with 29 CFR 1926.500 and USACE
EM 385-1-1.
b. Steep-Sloped Roofs: Work on steep-sloped roofs requires a personal fall arrest system, guardrails with toe-boards, or safety nets. This requirement also includes residential or housing type construction.
File details come from the government source that posted it. Updated .