DEPARTMENT OF THE AIR FORCE

86TH AIRLIFT WING (USAFE)

MEMORANDUM FOR ALL OFFERORS 20 Jun 13

FROM: 700 CONS/LGCE

Kapaun Air Station, Bldg. 2767

67661 Kaiserslautern

SUBJECT: Questions and responses FA5613-13-R-0019, Maintenance and Repair of Motor Pool

Equipment in the Kaiserslautern Military Community (KMC)

The responses are provided below the individual questions in bold.

QUESTION 1: Is there a new list of equipment where we can see how many and what typ and manufacture the Equipment today is.

RESPONSE: The Government has provided a list containing the requested information to the extent available with Amendment 0004.

QUESTION 2: Is the maintenance price in the solicitation list 001 -> 007… (1,2,3,4001 - 007 ->) with the parts or only for work hours – will the parts are paid over the Position 0008 – 1,2,3,4008

Reimbursement of Replacement Parts ? may be after the maintenance controlling with a separate estimate?

RESPONSE: Offerors shall provide prices in accordance with the instructions listed on page 32, paragraph (b)(6). Contract Line Item Numbers (CLINs) X001 through X007 shall contain prices for inspection and repair services for the respective system only. All replacement parts will be handled under CLINs X008; no prices are to be provided for these CLINs.

QUESTION 3:

Pos #6 – we now they are more than 5 Air Compressors in these Buildings but in the Solicitation list are only 5

Pos # 8 - Submit Quality Control Program/Plan – what the user need, please give us more information

Pos #4 - carbon monoxide exhaust systems – this will be 5 complete systems ?

(Only one of this system we now, will have 9 separately inlet systems)

RESPONSE:

Regarding Pos # 6 - The quantities listed in Appendix A shall be used for developing a proposal

Regarding Pos # 8 - Please see the PWS, paragraph 4.2

Regarding Pos # 4 - The equipment list provided with Amendment 0004 contains detailed information for the carbon monoxide exhaust systems.

Erich Fauss

Contract Specialist