Specifications:
- Must be at least 3’ long, 2’ wide at the base w/ a tapered base; 3’ long, 1’ wide at top
- Must be at least 12’ tall
- Concrete must be at least 4000PSI
- Must be reinforced with at least #5 rebar 12” on center w/ 2” clear space along vert wall and 3” clear space at base; typical
- Must come with lifting eyes w/ at least #5 rebar; 2 at top, 4 on either side
- Must come with continuous lifting recess(s) at base