The Government requires procurement of a single, fully integrated Counter-sUAS system that combines passive RF detection/telemetry demodulation capabilities with active RF electronic defeat capabilities in one unified system; standalone or non-integrated multi-component systems are technically unacceptable. Minimum mandatory performance thresholds include: passive detection range exceeding 4 km horizontal radius with drone ID and telemetry demodulation capability; active defeat range exceeding 3 km horizontal radius; RF power output exceeding 550 Watts across all operational defeat bands; and GNSS denial coverage with selectable and simultaneous denial of Galileo E1, GPS L1, Galileo E5, GPS L5, GPS L2, and Galileo E6 bands with operator-controlled variable RF output power. All proposed systems must meet or exceed these stated performance metrics. Additionally, the contractor must provide on-site advanced operator training at Andersen AFB accommodating a minimum of 4 personnel, with all training to be completed within 180 days of system delivery. Remote training is not acceptable for this requirement.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions for 736 SFS – CUAS System

1. The Salient Characteristics appear to include both a SkyView-MPV3 passive detection requirement and separate detect/defeat characteristics, including greater-than-3 km defeat range, greater-than-550 W RF power output, GNSS denial, and the larger chassis specifications. Please confirm the exact system configuration and quantities required under CLIN 0001. Specifically, is the Government requiring both a SkyView- MPV3 passive sensor and a separate detect/defeat system, or one integrated system/configuration?

This is procurement of a single system, it should be a Counter-sUAS system, which must integrate both passive radio frequency (RF) detection/telemetry demodulation capabilities and active RF electronic defeat capabilities within a single, unified/ cohesive system. Standalone, or non-integrated multi-component systems are technically unacceptable.

2. Please confirm whether the intended requirements are: Detection Range >4 km horizontal radius with drone ID/telemetry demodulation; Defeat Range >3 km horizontal radius; RF Power Output >550 W; and GNSS Denial Coverage selectable E1/L1, E5/L5, L2, and L6 bands with variable RF output.

Confirmed. The listed parameters represent the minimum mandatory threshold requirements. Any proposed system must meet or exceed all stated performance metrics

- Passive Detection: Passive RF-based detection, identification, and flight telemetry/controller demodulation at a horizontal radius of greater than 4 km. Active Defeat: Directed or omnidirectional RF electronic defeat at a horizontal radius of greater than 3 km. RF Power Output: Total RF power output of greater than 550 Watts across all operational defeat bands. GNSS Denial: Selectable and simultaneous denial coverage of Galileo E1, GPS L1, Galileo E5, GPS L5, GPS L2, and Galileo E6 bands with operator-controlled, variable RF output power.

3. The warranty section includes advanced operator training. Please confirm whether training must be conducted on-site at Andersen AFB, whether remote training is acceptable, the required number of operators, and whether training must be completed within the 120-day delivery period.

All training must be completed on-site within 180 days of delivery at Andersen AFB. This training must be able to fit at a minimum 4 personnel