Attachment 1 - 644 CBCS RF EMI Shielded Portable TSCIF Tent Revised 16SEP24.pdf
PDF 101 KB Posted
- Attached to
- RFQ- 644 CBCS Portable T-SCIF (2024)
- Solicitation number
- FA524024QM134
About this file
This document is an attachment to a Request for Quotes (RFQ) for a Radio Frequency (RF) Electromagnetic Interference (EMI) Shielded Portable TSCIF Tent. The key requirements are: the tent must be able to fit up to four individuals, have minimum interior dimensions of 9' x 9' x 6.5', provide RF EMI shielding, include a portable frame, and have a voice modulation or soundproofing system. The tent must also include a power supply, lighting, ventilation, and data ports. The solicitation has a response date of September 20, 2024 at 1:00pm Chamorro Standard Time and is a 100% Small Business Set-Aside acquisition under NAICS code 314910 with a size standard of 500 employees. The contracting agency is the Department of the Air Force Pacific Air Forces.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
16 September 2024 Attachment 1 – Salient Characteristics for RF EMI Portable Tent Revised 16SEP24
To be deemed technically acceptable, the following specifications respective to their line items, must meet the follow salient characteristics.
CLIN 0001 – Radio Frequency(RF) Electromagnetic Interference(EMI) Portable T-SCIF Tent -Must be able to fit up to four individuals when set up. Minimum interior dimensions must be at least nine feet long (9’) by nine feet wide (9’) by six and a half feet tall (6.5’). [9’ x 9’ x 6.5’] -Must be an EMI RF shielded tent that blocks all electromagnetic signals -Must include a portable and heavy duty frame -Must include portable travel cases that the tents fit into. Tent material must be lightweight and collapsible.
-Must include a voice modulator system or a soundproof system which provides for discussions within the tent to be unintelligible from the outside. Include a portable case for voice modulator or sound blocking system.
-Must include a 90-240VAC/12VDC power supply with US plug -Must include internal lighting system -Must have the following minimum attenuation: at least 85 dB at 1 GHz -Includes a power filter plate -Includes a ventilation system -Minimum door size must be at least five and half feet tall.
-System must be airline checkable when stored and able to be carried by one individual. System storage can include oversized case(s). Two are acceptable, in excess of two may be acceptable depending on single individual portability.
-Systems needs to include 2 to 4 RJ45 ports and at least 2 USB ports -System needs to provide multiple plugin capabilities as follows: for phone, VOIP, and VTC/SVTC interface capabilities.
-Must include standard warranty, at least three years.