This document is a set of Questions and Answers for Solicitation FA524024QM111, which is a Request for Quotes (RFQ) for HF/VHF/UHF Antennas. The solicitation is a 100% Women-Owned Small Business Set-Aside, with a NAICS code of 334220 and a small business size standard of 1,250 employees.
The key details are:
- The mast height required is 20ft minimum for VHF/UHF and 15ft for HF, and the mast must be roll-up rather than push-up or pneumatic. The VHF/UHF antenna must be embedded into the mast.
- The solicitation requires 32 connectors, with two connectors per 50-ft coax cable.
- No coax switch is needed to separate the VHF from the UHF.
- The required HF power output is 150W minimum, with 400W preferred.
- The solicitation closing date is 27 August 2024.
- The procuring agency is the Department of the Air Force, Pacific Air Forces.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 3 – Questions and Answers for Solicitation FA524024QM111 NOTE: This attachment includes inquiries and subsequent Government for solicitation FA524024QM111. Government responses herein function as a supplement and will be considered when evaluating offers for technical acceptability. Government responses are formatted in red font and bold
1. Question: What mast height do you need?
Government response: 20ft minimum for VHF/UHF, 15ft for HF.
2. Question: Can the mast be push up or pneumatic rather than roll up?
Government response: No.
3. Question: Can the V/U antenna be attached to the mast rather than embedded into the mast itself which will wear out quickly?
Government response: No.
4. Question: When you say you need 32 connectors is it right to assume you mean two connectors per coax cable, one on each end? I understand the cables need to be 50' in length.
Government response: Correct.
5. Question: Is a coax switch needed to separate the VHF from the UHF?
Government response: No.
6. Question: What is the power output wattage required for the HF part of the solicitation?
Government response: 150W minimum, 400W preferred.
7. Question: When is the close date on this RFQ Government response: 27 August 2024.