Appendix_A_-_SIPR_Power_Upgrade.pdf
PDF 227 KB Posted
- Solicitation number
- FA5209-17-R-8002
About this file
Appendix A: Floor Plan
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B
C
8 7 6 5 4 3 2 1
D
C
B
A
D
A
FOR CLASSIFIED DOCUMENTS, FOLLOW THE PROCEDURES IN DOD 5220.22-M, INDUSTRIAL SECURITY MANUAL, SECTION 11-19, OR DOD 5200.1-R, INFORMATION SECURITY PROGRAM REGULATION, CHAPTER IX.
DESTRUCTION NOTICE- FOR UNCLASSIFIED, LIMITED DOCUMENTS, DESTROY BY ANY METHOD THAT WILL PREVENT
DISCLOSURE OR RECONSTRUCTION OF THE DOCUMENT.
WARNING, EXPORT-CONTROLLEDDESTRUCTION NOTICE-
DISTRIBUTION F. FURTHER DISSEMINATION ONLY AS DIRECTED BY 374 CS/SCX,
YOKOTA AB, JAPAN 96328; JUN 2012; OR HIGHER DOD AUTHORITY.
REVISIONS
5PJB1
AIR FORCE CODE
IDENT NO
SIZE
D
AIR FORCE AUTHENTICATION
AIR FORCE RELEASE
ENG
CHK
DR
SCALE NONE
TITLE
374 CS/SCXP YOKOTA AIR BASE, JAPAN 96328
374th COMMUNICATIONS SQADRON
U.S. AIR FORCE
DRAWING NO.
SHEET OF
FOR OFFICIAL USE ONLY
CERTIFICATION CHANGES
INSTALLED
DATE
LTR DATEDESCRIPTION APPROVED
ZNREB00650FP380
Building 650 First Floor
Plan
2 9
24' – 1½” 23' – 11½” 23' – 11½” 23' – 11½” 23' – 11½” 23' – 1½” 23' – 1½” 23' – 11½” 23' – 11½” 23' – 11½” 24' – 1½”
59' - 6" 28' – 3½” 23' – 8” 23' – 1½” 24' – 11¾”
9' – ½” 12' – 1¾”
19' – 9½” 15' - 1"24'
25' – 7¼”
23' – 9½”
25' – 7¼”
75'
26' - 7" 18' – ½”
17' – 2¾”
18' – 6½”
44' – 3¾”
59' – 2½”
49' – 4½”
35' – 3½”
47' - 11"
35' – 8¾”
17' – 11¾” 53' – 9¼” 66' – 7¼”
121-D 121-C 121-B
121-E 121-A
15' - 1"
114-A
111-B
-A
-A
H V
A C
126125124123
120 116
134 104
122-A
HVAC
122-B
122-C
Power Panel 23
Main UPS panel
UPS A
UPS B
Load Balanced/Fail
Over Facility UPS
Pathway for electric cable from
Panel 23 to new power panels
B25 and TMGB to new TGBs
8 7 6 5 4 3 2 1
D
C
B
A
D
A
FOR CLASSIFIED DOCUMENTS, FOLLOW THE PROCEDURES IN DOD 5220.22-M, INDUSTRIAL SECURITY MANUAL, SECTION 11-19, OR DOD 5200.1-R, INFORMATION SECURITY PROGRAM REGULATION, CHAPTER IX.
DESTRUCTION NOTICE- FOR UNCLASSIFIED, LIMITED DOCUMENTS, DESTROY BY ANY METHOD THAT WILL PREVENT
DISCLOSURE OR RECONSTRUCTION OF THE DOCUMENT.
WARNING, EXPORT-CONTROLLEDDESTRUCTION NOTICE-
DISTRIBUTION F. FURTHER DISSEMINATION ONLY AS DIRECTED BY 374 CS/SCX,
YOKOTA AB, JAPAN 96328; JUN 2012; OR HIGHER DOD AUTHORITY.
REVISIONS
5PJB1
AIR FORCE CODE
IDENT NO
SIZE
D
AIR FORCE AUTHENTICATION
AIR FORCE RELEASE
ENG
CHK
DR
SCALE NONE
TITLE
374 CS/SCXP YOKOTA AIR BASE, JAPAN 96328
374th COMMUNICATIONS SQADRON
U.S. AIR FORCE
DRAWING NO.
SHEET OF
FOR OFFICIAL USE ONLY
CERTIFICATION CHANGES
INSTALLED
DATE
LTR DATEDESCRIPTION APPROVED
B01
72' – 6"
75'
24' – 1½” 23' 11½” 23' – 11½” 23' – 11½” 23' – 11½” 23' – 1½” 23' – 1½” 23' – 11½” 23' – 11½” 23' – 11½” 24' – 1½”
B02 B03 B04 B05 B07 B08 B09 B10
B06 B11
B13
B12 B15 B16
B14
B27
B26
B29
B25
B19 B20 B21 B22
B17 B18
B23
B24
B28
U P
UP
UP
UP
HVAC
H V
A C
25' – 7¼”
23' – 9½”
25' – 7¼”
ZNREB00650FP380
Building 650 Basement
Floor Plan
5 9
B30
65' – 11" 36' – 11" 64' – 10" 8'
6' – 5"
11' – 9¾”7' – 2" 12' 12' 18' – ½” 12' 12' 15' – 9¼”
15' – 9¼”
20' – 7"
14' – 6¼” 17' – 7½” 15' – 2½”
22' – 10¼”
40' – 4¼”
19' – 8½”
48' – 10½”
Pathway for electric cable from
Panel 23 to new power panels
B25 and TMGB to new TGBs
ExistingTMGB
Under the Floor
8 7 6 5 4 3 2 1
D
C
B
A
D
A
FOR CLASSIFIED DOCUMENTS, FOLLOW THE PROCEDURES IN DOD 5220.22-M, INDUSTRIAL SECURITY MANUAL, SECTION 11-19, OR DOD 5200.1-R, INFORMATION SECURITY PROGRAM REGULATION, CHAPTER IX.
DESTRUCTION NOTICE- FOR UNCLASSIFIED, LIMITED DOCUMENTS, DESTROY BY ANY METHOD THAT WILL PREVENT
DISCLOSURE OR RECONSTRUCTION OF THE DOCUMENT.
WARNING, EXPORT-CONTROLLEDDESTRUCTION NOTICE-
DISTRIBUTION F. FURTHER DISSEMINATION ONLY AS DIRECTED BY 374 CS/SCX,
YOKOTA AB, JAPAN 96328; JUN 2012; OR HIGHER DOD AUTHORITY.
REVISIONS
5PJB1
AIR FORCE CODE
IDENT NO
SIZE
D
AIR FORCE AUTHENTICATION
AIR FORCE RELEASE
ENG
CHK
DR
SCALE NONE
TITLE
374 CS/SCXP YOKOTA AIR BASE, JAPAN 96328
374th COMMUNICATIONS SQADRON
U.S. AIR FORCE
DRAWING NO.
SHEET OF
FOR OFFICIAL USE ONLY
CERTIFICATION CHANGES
INSTALLED
DATE
LTR DATEDESCRIPTION APPROVED
ZNREB00650FP380
7 9
B25
H V
A C
23' – 11½” 23' – 11½” 23' – 11½”
64' – 10" 8'
25' – 7¼”
14' – 9"
40' – 4¼”
Building 650 Room B25
Each cabinet (5) shall have two (2)
L6-30R from each power panel installed under them on a whip. Four
(4) L6-30R per cabinet, twenty (20)
L6-30R total
New Power Panel 208v 4W
300A Main breaker with 38 each 2P-30A circuit breakers
Two (2) new TGB connected back to TMGB in room 103
| Bldg 650 D Size.vsdx |
| Legend |
| First Floor |
| 109 |
| 122 |
| Basement |
| B06 |
| B25 |
| B26 |
| B26 - E |
File details come from the government source that posted it. Updated .