6.PWS_Appendix_B_-_Solvent_Properties_ _Test_Methods.xlsx
XLSX spreadsheet 11 KB Posted
- Attached to
- Parts Washer Solvent Replacement for Yokota Air Base and Tama Service Annex, Tokoyo, Japan
- Solicitation number
- FA520915T0171
About this file
PWS Appendix B (Added)
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Minutes_for_Pre-proposal_Conference.pdf | ||
| 1.FA520915T0171-Amendment0001.pdf | ||
| 5.PWS_Appendix_A-_service_Locations_and_Service_Schedule_v2.xlsx | XLSX spreadsheet | |
| 4.PWS_Parts_Washer_solvent_replacement_rev20150820.docx | DOCX document | |
| 3.Exhibit_1_-_Pricing_Schedule.xlsx | XLSX spreadsheet | |
| 2.FA520915T0171-ConformedDocument.pdf | ||
| 6.Envelope_label_OF-17.pdf | ||
| 4.SolicitationAttach1-PWS.docx | DOCX document | |
| 1.Notice_to_Offerors_for_FA520915T0171.pdf | ||
| 2.Government_Policy_Letter.pdf | ||
| 3.Solicitation__FA520915T0171.doc | DOC document | |
| 5.PWS_Appendix_A-_Service_Locations_and_Service_Schedule.xlsx | XLSX spreadsheet |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Appendix B for Performance Work Statement - Solvent Properties and Test Methods required by MIL-PRF-680 | ||
| MIL-PRF-680 Type II | ||
| Properties | Test Methods for Inspections | |
| Flash point °C(°F) | 61-92(141-198) | ASTM methods D56 |
| Distillation °C | ASTM methods D86 | |
| Initial boiling pt., minimum (min) | 177 | |
| Dry point °C, maximum (max) | 212 | |
| Kauri-Butanol value | 27 to 45 | ASTM methods D1133 |
| Aromatic content, vol %., max | 1 | ASTM methods D3257 |
| Total phenol content, parts per million (ppm), max | 0.5 | EPA 420.1 |
| Dichlorobenzene, milligrams per liter (mg/L) , max Benzene, mg/L, max | 0.5, 0.5 | EPA 3585 and 8260B |
| Tetrachloroethylene, mg/L, max | 0.7 | EPA 3585 and 8260B |
| Trichloroethylene, mg/L, max | 0.5 | EPA 3585 and 8260B |
| Apparent specific gravity, 60/60F | 0.754 to 0.82 | ASTM methods D1298 |
| Total chlorine content (PPM), Max | 100 | |
| Non-volatile residue, (mg/100mL), max | 8 | ASTM methods D1353 |
| Color, min | 25 | ASTM methods D156 |
| Odor | low & non-residual | ASTM methods D1296 |
| Corrosion, copper, max | 1b | ASTM methods D130 |
| Sandwich corrosion, max | 1 | ASTM methods F1110 |
| Total immersion corrosion | Pass | ASTM methods F483 |
| Titanium stress corrosion | No cracking | ASTM methods F945 |
| Acidity | Neutral | ASTM methods D847 |
| Doctor test | Negative | ASTM methods D235 |
| Vapor pressure, millimeters of Mercury (mm Hg) @ 20°C, max | 2 | ASTM methods D2879 |
| Soil cleaning test, %, min | 85 | FED-STD-791 Method, 7502 |
| VOC, g/l, max | NR | SCAQMD 313 |