FA520525QB054 - Questions and Answers.pdf
PDF 113 KB Posted
- Attached to
- Haz Storage, Misawa Air Base, Japan Federal contract opportunity
- Solicitation number
- FA520525QB036
About this file
This document is a Questions and Answers file for a hazardous materials storage locker solicitation for Misawa Air Base, Japan. The Q&A provides detailed specifications for a 16-drum storage unit, including chemical storage requirements (Hydraulic Fluid, Coolant, PAO, Oil), fire safety specifications (4-hour fire-rated model, minimum 10' distance from building), and electrical requirements (internal lighting at 120volts/50Hz, 20 amps). The storage unit will be placed on a concrete surface and does not require HVAC.
Shipping and delivery details include two potential addresses: one at Misawa Air Base in Japan (Unit 5016, APO AP 96319) and an alternate stateside delivery location at the Defense Logistics Agency Distribution Depot in Tracy, CA. The military unit associated with the procurement is FB5205 35 LRD LGRD. This solicitation is part of a federal contract opportunity issued by the Department of the Air Force Pacific Air Forces, specifically seeking a hazardous materials storage solution with specific safety and functional requirements.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 0003 to FA520525QB036 - Haz Storage.pdf | ||
| Amendment 0002 to FA520525QB036 - Haz Storage.pdf | ||
| Amendment 0001 to FA520525QB036 - Haz Storage.pdf | ||
| FA520525QB036 - Haz Storage.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
QUESTIONS AND ANSWERS
1. Types of chemicals being stored?
Hydraulic Fluid, Coolant, PAO, Oil
2. Building size needed for your site location?
16 Drums
3. Single bay or separate bay storage required for separating incompatible chemicals?
Single Bay
4. Fire-rating required?
The Haz Storage must be at least 10’ Feet or Less Distance from building, a 4 hour fire-rated model will be required.
5. Any electrical options required including lights, HVAC and dry chemical fire suppression required, and please confirm the electrical supply voltage and phase available if known.
Internal Lighting is needed (120volts/50Hz/ rated at 20amps)
6. The temperature range that you need to meet for any of the HVAC options required.
HVAC is not Required
7. Please provide the military unit and address as needed to prepare your quote.
FB5205 35 LRD LGRD
UNIT 5016 APO AP 96319-5016
8. There are two shipping addresses. Which one should we quote delivery to?
If you are looking to do direct shipping from stateside, you would ship to the address below:
ATTN: MSgt Dustin Grantom (315) 226-1330
13 FGS/MXAQF
Unit 5016, APO AP 96319 Misawa Air Base, Japan
The second address in that line is specific for if you are shipping from inside Japan.
Also, the address we recommend shipping to (if you are stateside) is the address listed below:
Defense Logistics Agency Defense Distribution Depot San Joaquin (DDJC), Tracy Depot Address: Bldg. 30, CCP, 25600 Chrisman Road, Tracy, CA 95376
9. Is the ground at the installation site asphalt, concrete, or dirt?
The ground beneath the storage locker will be concrete.