3. Q&A - ROWPU.pdf
PDF 74 KB Posted
- Attached to
- Reverse Osmosis Water Purification Unit (ROWPU)
- Solicitation number
- FA520524QB034
About this file
This document appears to be a Q&A related to a Solicitation (FA520524QB034) for a Reverse Osmosis Water Purification Unit (ROWPU) issued by the Department of the Air Force Pacific Air Forces.
The key details are:
- The ROWPU is required to be capable of operating on 115V 50Hz or 240V 50Hz power, with a preference for a dedicated generator.
- The end use of the water is to clean a water source and release it to the environment, with the potential for human consumption in contingency operations.
- The feed water source is brackish water. The water quality requirements include reducing PFOS/A content below 50ppm.
- The work will be performed in Japan, and the contractor must be authorized to operate and do business in Japan.
- The solicitation does not obligate the government to award a contract or pay for bid/proposal preparation costs.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1. RFQ 0003.pdf | ||
| 1. RFQ 0002.pdf | ||
| 1. RFQ 0001.pdf | ||
| 1. RFQ.pdf | ||
| 2. Clauses.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
What type of SCADA system is onsite?
Is the system to be rated for electricity service for Japan or the USA?
Is a delivery time of 120 days acceptable? Yes
None, we are looking to add SCADA system later on at the shop located on the oposite side of the installation from the work site, thus we are requesting a transmitter be incorporated to the unit if possible
115V 50HZ is most prevalent, but 240V 50HZ is available on the work site; a dedicated genetator for the unit is desired but not necessary in case of power outage.
The intent is to clean the source and release to the environment
Is fresh water, mostly rain
Yes
Military
Is it acceptable for the trailer to be an enclosed trailer such as a cargo trailer?
Will the work being performed by the US contractor be for the US military?
Is the ROWPU being operated only on base at Misawa Air base in Japan?
What is the end use of the water?
Questions FA520524QB034: Reverse Osmosis Water Purification Unit Q&A
Yes
What is the quality of water required?
Another way of asking is the water to be used for human consumption or technical use.
Are the specs for stainless steel for the filter itself or the housing for the filter?
What will the feed water source be?
Answers
The housing
Brackish water
Is the water being produced for human consumption? (potable water)
Yes, the original intent is to reduce the water source PFOS/A content below 50ppm. In the event of contingency operations, it can potentially be utilized for human consumption.
Sheet1
File details come from the government source that posted it. Updated .