This is a solicitation for a firm fixed price construction contract. The U.S. Air Force is seeking bids to upgrade and repair the Parachute Shop at Eielson Air Force Base in Alaska, including exterior walls, roofing, structural, plumbing, HVAC, lighting, electrical and fire protection systems, as well as interior configuration and site work. The estimated value is between $1 million and $5 million. A pre-bid site visit will be held on December 19th and questions are due by December 27th. Electronic bids will not be accepted. Bids must remain valid until April 8th, 2020. The bid opening will be on January 9th, 2020. Points of contact are provided for any questions regarding this solicitation.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Submittal Register
| TITLE: | FINAL CONSTRUCTION DOCUMENT | SUBMITTAL REGISTER | ||||||||||||||||||
| JOB NAME: | REPAIR PARACHUTE SHOP | |||||||||||||||||||
| LOCATION: | EIELSON AFB, ALASKA | |||||||||||||||||||
| CONTRACT NO: | FTQW 19-1003 | |||||||||||||||||||
| CONTRACTOR: | ||||||||||||||||||||
| CONTRACTOR SCHEDULE DATES | CONTRACTOR ACTION | APPROVING AUTHORITY | ||||||||||||||||||
| (a) | (b) | (c) | (d) | (e) | (f) | (g) | (h) | (i) | (j) | (k) | (l) | (m) | (n) | (o) | (p) | (q) | (r) | |||
| Line | Activity # | Trans-mittal # | Specification Section | SD # | Submittal Description | Item Submitted | Paragraph # | Classification: GOVT or A/E Revwr | Submit | Approval Needed By | Material Needed By | Action Code | Date Of Action | Date FWD to APPR / Auth Date RCD From CONTR | Date FWD To Other Revwr | Date RCD From Other Revwr | Action Code | Date Of Action | Mailed To CONTR/ Date RCD From APPR Authority | Remarks |
| 1 | 01 30 00 | 01 | Preconstruction Submittals | View Location Map | 1.4 | |||||||||||||||
| 2 | 01 30 00 | 01 | Preconstruction Submittals | Progress and Completion Pictures | 1.5 | |||||||||||||||
| 3 | 01 30 00 | 04 | Samples | Color Boards | 1.3 | G | ||||||||||||||
| 4 | 01 32 16.00 20 | 01 | Preconstruction Submittals | Baseline Construction Schedule | 1.2 | |||||||||||||||
| 5 | 01 32 16.00 20 | 07 | Certificates | Monthly Updates | 1.4 | |||||||||||||||
| 6 | 01 33 29 | 01 | Preconstruction Submittals | Preliminary High Performance and Sustainable Building Checklist | 1.5.3.1 | |||||||||||||||
| 7 | 01 33 29 | 01 | Preconstruction Submittals | Sustainability Action Plan | 1.4.1 | |||||||||||||||
| 8 | 01 33 29 | 01 | Preconstruction Submittals | Preliminary Sustainability eNotebook | 1.5.3.1 | |||||||||||||||
| 9 | 01 33 29 | 11 | Closeout Submittals | Final High Performance and Sustainable Building Checklist | 1.5.3.1 | G | ||||||||||||||
| 10 | 01 33 29 | 11 | Closeout Submittals | Final Sustainability eNotebook | 1.5.3.1 | G | ||||||||||||||
| 11 | 01 33 29 | 11 | Closeout Submittals | Third Party Certification Certificate, Assessment, or Validation | 3.2 | |||||||||||||||
| 12 | 01 35 26 | 01 | Preconstruction Submittals | Accident Prevention Plan (APP) | 1.6 | |||||||||||||||
| 13 | 01 35 26 | 06 | Test Reports | Notifications and Reports | 1.11 | |||||||||||||||
| 14 | 01 35 26 | 06 | Test Reports | Accident Reports | 1.11.2 | G | ||||||||||||||
| 15 | 01 35 26 | 06 | Test Reports | LHE Inspection Reports | 1.11.3 | |||||||||||||||
| 16 | 01 35 26 | 07 | Certificates | Crane Operators/Riggers | 1.5.1.4 | |||||||||||||||
| 17 | 01 35 26 | 07 | Certificates | Standard Lift Plan | 1.6.2.2 | |||||||||||||||
| 18 | 01 35 26 | 07 | Certificates | Critical Lift Plan | 1.6.2.3 | G | ||||||||||||||
| 19 | 01 35 26 | 07 | Certificates | Activity Hazard Analysis (AHA) | 1.7 | |||||||||||||||
| 20 | 01 35 26 | 07 | Certificates | Confined Space Entry Permit | 1.8.1 | |||||||||||||||
| 21 | 01 35 26 | 07 | Certificates | Hot Work Permit | 1.8.1 | G | ||||||||||||||
| 22 | 01 35 26 | 07 | Certificates | Certificate of Compliance | 1.11.4 | |||||||||||||||
| 23 | 01 35 26 | 07 | Certificates | License Certificates | 1.13 | |||||||||||||||
| 24 | 01 45 00.00 10 | 01 | Preconstruction Submittals | Contractor Quality Control (CQC) Plan | 3.2 | G | ||||||||||||||
| 25 | 01 45 00.00 10 | 06 | Test Reports | Verification Statement | 3.5.2 | |||||||||||||||
| 26 | 01 45 35 | 06 | Test Reports | Biweekly Reports | 3.1.1 | |||||||||||||||
| 27 | 01 45 35 | 07 | Certificates | Wood Truss Plant | 2.1 | |||||||||||||||
| 28 | 01 45 35 | 07 | Certificates | Ac472 Accreditation | 0 | |||||||||||||||
| 29 | 01 45 35 | 07 | Certificates | Special Inspector | 0 | |||||||||||||||
| 30 | 01 45 35 | 11 | Closeout Submittals | Interim Final Report | 3.1.2 | |||||||||||||||
| 31 | 01 45 35 | 11 | Closeout Submittals | Comprehensive Final Report | 3.1.2 | |||||||||||||||
| 32 | 01 50 00 | 01 | Preconstruction Submittals | Construction Site Plan | 1.3 | G | ||||||||||||||
| 33 | 01 50 00 | 01 | Preconstruction Submittals | Traffic Control Plan | 3.4.1 | G | ||||||||||||||
| 34 | 01 57 19 | 01 | Preconstruction Submittals | Preconstruction Survey | 1.6.1 | |||||||||||||||
| 35 | 01 57 19 | 01 | Preconstruction Submittals | Regulatory Notifications | 1.6.2 | |||||||||||||||
| 36 | 01 57 19 | 01 | Preconstruction Submittals | Environmental Protection Plan (EPP) | 0 | G | ||||||||||||||
| 37 | 01 57 19 | 01 | Preconstruction Submittals | Stormwater Notice of Intent and copy of ADEC approval | 0 | |||||||||||||||
| 38 | 01 57 19 | 01 | Preconstruction Submittals | Dirt and Dust Control Plan | 1.7.11.1 | |||||||||||||||
| 39 | 01 57 19 | 01 | Preconstruction Submittals | Employee Training Records | 1.6.5 | |||||||||||||||
| 40 | 01 57 19 | 01 | Preconstruction Submittals | Environmental Manager Qualifications | 1.6.4 | |||||||||||||||
| 41 | 01 57 19 | 01 | Preconstruction Submittals | Completed Checklist For Spruce Lake Disposal | 0 | G | ||||||||||||||
| 42 | 01 57 19 | 01 | Preconstruction Submittals | Notice of Intent For Asbestos Abatement | 0 | |||||||||||||||
| 43 | 01 57 19 | 01 | Preconstruction Submittals | Notice Of Building Demolition | 0 | |||||||||||||||
| 44 | 01 57 19 | 01 | Preconstruction Submittals | Stormwater Pollution Prevention Plan (SWPPP) | 0 | |||||||||||||||
| 45 | 01 57 19 | 01 | Preconstruction Submittals | Evidence Of Delivery Of SWPPP to ADEC | 0 | |||||||||||||||
| 46 | 01 57 19 | 01 | Preconstruction Submittals | Contaminated Soil Sampling And Analysis Plan (SAP) | 0 | G | ||||||||||||||
| 47 | 01 57 19 | 01 | Preconstruction Submittals | Contaminated Soil Sampling And Analysis Field Report | 0 | |||||||||||||||
| 48 | 01 57 19 | 01 | Preconstruction Submittals | Initial Contractor Hazardous Material Inventory | 0 | G | ||||||||||||||
| 49 | 01 57 19 | 06 | Test Reports | Laboratory Analysis | 3.7.1.1.2 | |||||||||||||||
| 50 | 01 57 19 | 06 | Test Reports | Inspection Reports | 3.2.1.3 | |||||||||||||||
| 51 | 01 57 19 | 06 | Test Reports | Solid Waste Management Report | 3.7.2.1 | |||||||||||||||
| 52 | 01 57 19 | 07 | Certificates | Employee Training Records | 1.6.5 | |||||||||||||||
| 53 | 01 57 19 | 07 | Certificates | Erosion and Sediment Control Inspector | 1.6.5 | |||||||||||||||
| 54 | 01 57 19 | 07 | Certificates | ADEC Transport, Treatment, & Disposal Approval Form For Contaminated Media (ATT) | 0 | G | ||||||||||||||
| 55 | 01 57 19 | 11 | Closeout Submittals | Stormwater Pollution Prevention Plan Compliance Notebook | 3.2.1.4 | |||||||||||||||
| 56 | 01 57 19 | 11 | Closeout Submittals | Stormwater Notice of Termination to ADEC | 0 | |||||||||||||||
| 57 | 01 57 19 | 11 | Closeout Submittals | Waste Determination Documentation | 3.7.1 | |||||||||||||||
| 58 | 01 57 19 | 11 | Closeout Submittals | Disposal Documentation for Hazardous and Regulated Waste | 3.7.3.6 | G | ||||||||||||||
| 59 | 01 57 19 | 11 | Closeout Submittals | Assembled Employee Training Records | 1.6.5 | |||||||||||||||
| 60 | 01 57 19 | 11 | Closeout Submittals | Solid Waste Management Permit | 0 | G | ||||||||||||||
| 61 | 01 57 19 | 11 | Closeout Submittals | Solid Waste Management Report | 3.7.2.1 | G | ||||||||||||||
| 62 | 01 57 19 | 11 | Closeout Submittals | Hazardous Waste/Debris Management | 3.7.3.1 | G | ||||||||||||||
| 63 | 01 57 19 | 11 | Closeout Submittals | Regulatory Notifications | 1.6.2 | |||||||||||||||
| 64 | 01 57 19 | 11 | Closeout Submittals | Sales Documentation | 3.7.2.1 | |||||||||||||||
| 65 | 01 57 19 | 11 | Closeout Submittals | Contractor Certification | 0 | |||||||||||||||
| 66 | 01 57 19 | 11 | Closeout Submittals | As-Built Topographic Survey | 0 | G | ||||||||||||||
| 67 | 01 57 19 | 11 | Closeout Submittals | ADEC Approved Disposal Facility Weight and/or Acceptance Ticket for Contaminated Soil | 0 | G | ||||||||||||||
| 68 | 01 57 19 | 11 | Closeout Submittals | ADEC Approved Disposal Facility Certificate of Thermal Incineration or Disposal of Contaminated Soil along with Confirmatory Sample Results | 0 | G | ||||||||||||||
| 69 | 01 58 00 | 02 | Shop Drawings | Preliminary Drawing Indicating Layout And Text Content | 1.3.1 | G | ||||||||||||||
| 70 | 01 74 19 | 01 | Preconstruction Submittals | Waste Management Plan | 1.6 | G S | ||||||||||||||
| 71 | 01 74 19 | 11 | Closeout Submittals | Records | 1.7 | S | ||||||||||||||
| 72 | 01 78 00 | 03 | Product Data | Warranty Management Plan | 1.6.1 | G | ||||||||||||||
| 73 | 01 78 00 | 03 | Product Data | Warranty Tags | 1.6.3 | G | ||||||||||||||
| 74 | 01 78 00 | 03 | Product Data | Spare Parts Data | 1.4 | G | ||||||||||||||
| 75 | 01 78 00 | 08 | Manufacturer’s Instructions | Instructions | 1.6.1 | G | ||||||||||||||
| 76 | 01 78 00 | 10 | Operation and Maintenance Data | Operation and Maintenance Manuals | 3.6 | G | ||||||||||||||
| 77 | 01 78 00 | 11 | Closeout Submittals | As-Built Drawings | 3.1 | G | ||||||||||||||
| 78 | 01 78 00 | 11 | Closeout Submittals | Record Drawings | 3.2 | G | ||||||||||||||
| 79 | 01 78 00 | 11 | Closeout Submittals | As-Built Record Of Equipment And Materials | 3.5 | G | ||||||||||||||
| 80 | 01 78 00 | 11 | Closeout Submittals | Final Approved Shop Drawings | 3.3 | G | ||||||||||||||
| 81 | 01 78 00 | 11 | Closeout Submittals | Construction Contract Specifications | 3.4 | G | ||||||||||||||
| 82 | 01 78 00 | 11 | Closeout Submittals | Interim DD Form 1354 | 3.8 | G | ||||||||||||||
| 83 | 01 78 00 | 11 | Closeout Submittals | Checklist For DD Form 1354 | 3.8 | G | ||||||||||||||
| 84 | 01 78 23 | 10 | Operation and Maintenance Data | O&M Database | 1.3 | G | ||||||||||||||
| 85 | 01 78 23 | 10 | Operation and Maintenance Data | Training Plan | 3.1.1 | G | ||||||||||||||
| 86 | 01 78 23 | 10 | Operation and Maintenance Data | Training Outline | 3.1.3 | G | ||||||||||||||
| 87 | 01 78 23 | 10 | Operation and Maintenance Data | Training Content | 3.1.2 | G | ||||||||||||||
| 88 | 01 78 23 | 11 | Closeout Submittals | Training Video Recording | 3.1.4 | G | ||||||||||||||
| 89 | 01 78 23 | 11 | Closeout Submittals | Validation of Training Completion | 3.1.6 | |||||||||||||||
| 90 | 01 91 00.15 | 01 | Preconstruction Submittals | Commissioning Firm | 1.7 | |||||||||||||||
| 91 | 01 91 00.15 | 01 | Preconstruction Submittals | Lead Commissioning Specialist | 1.7.1 | |||||||||||||||
| 92 | 01 91 00.15 | 01 | Preconstruction Submittals | Technical Commissioning Specialists | 1.7.2 | |||||||||||||||
| 93 | 01 91 00.15 | 01 | Preconstruction Submittals | Commissioning Firm's Contract | 1.7 | |||||||||||||||
| 94 | 01 91 00.15 | 06 | Test Reports | Interim Construction Phase Commissioning Plan | 3.1.2.1 | G | ||||||||||||||
| 95 | 01 91 00.15 | 06 | Test Reports | Final Construction Phase Commissioning Plan | 3.1.2.2 | G | ||||||||||||||
| 96 | 01 91 00.15 | 06 | Test Reports | Building Envelope Inspection Checklists | 3.1.4.2 | |||||||||||||||
| 97 | 01 91 00.15 | 06 | Test Reports | Pre-Functional Checklists | 3.1.4.3 | |||||||||||||||
| 98 | 01 91 00.15 | 06 | Test Reports | Issues Log | 1.9 | |||||||||||||||
| 99 | 01 91 00.15 | 06 | Test Reports | Commissioning Report | 3.2 | G | ||||||||||||||
| 100 | 01 91 00.15 | 06 | Test Reports | Post-Construction Trend Log Report | 3.3.1 | |||||||||||||||
| 101 | 01 91 00.15 | 07 | Certificates | Certificate of Readiness | 1.10 | |||||||||||||||
| 102 | 01 91 00.15 | 11 | Closeout Submittals | Final Commissioning Report | 3.2 | G S | ||||||||||||||
| 103 | 02 26 00 | 01 | Preconstruction Submittals | Hazardous Materials Work Plan | 0 | G | ||||||||||||||
| 104 | 02 26 00 | 06 | Test Reports | Quality Control | 0 | G | ||||||||||||||
| 105 | 02 26 00 | 11 | Closeout Submittals | Closeout Reports | 0 | G | ||||||||||||||
| 106 | 02 41 00 | 01 | Preconstruction Submittals | Demolition/Deconstruction Plan | 1.2.2 | G | ||||||||||||||
| 107 | 02 41 00 | 01 | Preconstruction Submittals | Existing Conditions | 1.11 | |||||||||||||||
| 108 | 02 41 00 | 07 | Certificates | Notification | 1.7 | G | ||||||||||||||
| 109 | 02 41 00 | 11 | Closeout Submittals | Receipts | 3.3.4 | G | ||||||||||||||
| 110 | 02 61 13 | 02 | Shop Drawings | Surveys | 3.1 | |||||||||||||||
| 111 | 02 61 13 | 03 | Product Data | Work Plan | 1.3 | G | ||||||||||||||
| 112 | 02 61 13 | 03 | Product Data | Closure Report | 3.10 | |||||||||||||||
| 113 | 02 61 13 | 06 | Test Reports | Backfill | 2.2 | G | ||||||||||||||
| 114 | 02 61 13 | 06 | Test Reports | Surveys | 3.1 | |||||||||||||||
| 115 | 02 61 13 | 06 | Test Reports | Confirmation Sampling and Analysis | 3.5 | |||||||||||||||
| 116 | 02 61 13 | 06 | Test Reports | Sampling of Stored Material | 3.7.1 | |||||||||||||||
| 117 | 02 61 13 | 06 | Test Reports | Sampling Liquid | 3.7.2 | |||||||||||||||
| 118 | 02 61 13 | 06 | Test Reports | Compaction | 0 | G | ||||||||||||||
| 119 | 02 82 00 | 03 | Product Data | Amended Water | 1.2.2 | G | ||||||||||||||
| 120 | 02 82 00 | 03 | Product Data | Safety Data Sheets (SDS) for All Materials | 1.3.9 | G | ||||||||||||||
| 121 | 02 82 00 | 03 | Product Data | Encapsulants | 2.1 | G | ||||||||||||||
| 122 | 02 82 00 | 03 | Product Data | Respirators | 3.1.2.1 | G | ||||||||||||||
| 123 | 02 82 00 | 03 | Product Data | Local Exhaust Equipment | 3.1.7 | G | ||||||||||||||
| 124 | 02 82 00 | 03 | Product Data | Pressure Differential Automatic Recording Instrument | 3.1.7 | G | ||||||||||||||
| 125 | 02 82 00 | 03 | Product Data | Vacuums | 3.1.8 | G | ||||||||||||||
| 126 | 02 82 00 | 03 | Product Data | Glovebags | 0 | G | ||||||||||||||
| 127 | 02 82 00 | 06 | Test Reports | Air Sampling Results | 1.5.5 | G | ||||||||||||||
| 128 | 02 82 00 | 06 | Test Reports | Pressure Differential Recordings for Local Exhaust System | 1.5.6 | G | ||||||||||||||
| 129 | 02 82 00 | 06 | Test Reports | Encapsulation Test Patches | 0 | G | ||||||||||||||
| 130 | 02 82 00 | 06 | Test Reports | Clearance Sampling | 3.2.12.5 | G | ||||||||||||||
| 131 | 02 82 00 | 06 | Test Reports | Asbestos Disposal Quantity Report | 3.3.3.2 | G | ||||||||||||||
| 132 | 02 82 00 | 07 | Certificates | Employee Training | 1.3.4 | G | ||||||||||||||
| 133 | 02 82 00 | 07 | Certificates | Notifications | 1.3.5 | G | ||||||||||||||
| 134 | 02 82 00 | 07 | Certificates | Respiratory Protection Program | 1.3.7 | G | ||||||||||||||
| 135 | 02 82 00 | 07 | Certificates | Asbestos Hazard Abatement Plan | 1.3.10 | G | ||||||||||||||
| 136 | 02 82 00 | 07 | Certificates | Testing Laboratory | 1.3.11 | G | ||||||||||||||
| 137 | 02 82 00 | 07 | Certificates | Landfill Approval | 1.3.12 | G | ||||||||||||||
| 138 | 02 82 00 | 07 | Certificates | Delivery Tickets | 1.3.12 | G | ||||||||||||||
| 139 | 02 82 00 | 07 | Certificates | Waste Shipment Records | 1.3.12 | G | ||||||||||||||
| 140 | 02 82 00 | 07 | Certificates | Transporter Certification | 1.3.13 | G | ||||||||||||||
| 141 | 02 82 00 | 07 | Certificates | Medical Certification | 1.3.14 | G | ||||||||||||||
| 142 | 02 82 00 | 07 | Certificates | Private Qualified Person Documentation | 1.5.1 | G | ||||||||||||||
| 143 | 02 82 00 | 07 | Certificates | Competent Person | 1.5.2 | G | ||||||||||||||
| 144 | 02 82 00 | 07 | Certificates | Worker's License | 1.5.3 | G | ||||||||||||||
| 145 | 02 82 00 | 07 | Certificates | Contractor's License | 1.5.4 | G | ||||||||||||||
| 146 | 02 82 00 | 07 | Certificates | Federal, State or Local Citations on Previous Projects | 1.5.8 | G | ||||||||||||||
| 147 | 02 82 00 | 07 | Certificates | Encapsulants | 2.1 | G | ||||||||||||||
| 148 | 02 82 00 | 07 | Certificates | Equipment Used to Contain Airborne Asbestos Fibers | 3.1 | G | ||||||||||||||
| 149 | 02 82 00 | 07 | Certificates | Water Filtration Equipment | 3.1.3.3 | G | ||||||||||||||
| 150 | 02 82 00 | 07 | Certificates | Vacuums | 3.1.8 | G | ||||||||||||||
| 151 | 02 82 00 | 07 | Certificates | Ventilation Systems | 3.1.8 | G | ||||||||||||||
| 152 | 02 82 00 | 11 | Closeout Submittals | Permits and Licenses | 1.3.5 | G | ||||||||||||||
| 153 | 02 82 00 | 11 | Closeout Submittals | Notifications | 1.3.5 | G | ||||||||||||||
| 154 | 02 82 00 | 11 | Closeout Submittals | Respirator Program Records | 1.3.7.1 | G | ||||||||||||||
| 155 | 02 82 00 | 11 | Closeout Submittals | Protective Clothing Decontamination Quality Control Records | 1.5.7 | G | ||||||||||||||
| 156 | 02 82 00 | 11 | Closeout Submittals | Rental Equipment | 1.7.1 | G | ||||||||||||||
| 157 | 02 83 00 | 01 | Preconstruction Submittals | Competent Person | 1.5.1.1 | G | ||||||||||||||
| 158 | 02 83 00 | 01 | Preconstruction Submittals | Training Certification | 1.5.1.2 | G | ||||||||||||||
| 159 | 02 83 00 | 01 | Preconstruction Submittals | Occupational and Environmental Assessment Data Report | 1.5.2.3 | G | ||||||||||||||
| 160 | 02 83 00 | 01 | Preconstruction Submittals | Medical Examinations | 1.5.2.4 | G | ||||||||||||||
| 161 | 02 83 00 | 01 | Preconstruction Submittals | Lead Waste Management Plan | 1.5.2.8 | G | ||||||||||||||
| 162 | 02 83 00 | 01 | Preconstruction Submittals | Licenses, Permits and Notifications | 1.5.4 | G | ||||||||||||||
| 163 | 02 83 00 | 01 | Preconstruction Submittals | Occupant Protection Plan | 1.5.5 | G | ||||||||||||||
| 164 | 02 83 00 | 01 | Preconstruction Submittals | Lead, Cadmium, Chromium Compliance Plan | 0 | G | ||||||||||||||
| 165 | 02 83 00 | 01 | Preconstruction Submittals | Written Evidence of TSD Approval | 3.5.1.1 | G | ||||||||||||||
| 166 | 02 83 00 | 03 | Product Data | Respirators | 1.6.1 | G | ||||||||||||||
| 167 | 02 83 00 | 03 | Product Data | Vacuum Filters | 1.6.4 | G | ||||||||||||||
| 168 | 02 83 00 | 03 | Product Data | Negative Air Pressure System | 1.6.7 | G | ||||||||||||||
| 169 | 02 83 00 | 03 | Product Data | Materials and Equipment | 2.1 | G | ||||||||||||||
| 170 | 02 83 00 | 03 | Product Data | Expendable Supplies | 2.1.1 | G | ||||||||||||||
| 171 | 02 83 00 | 03 | Product Data | Local Exhaust Equipment | 3.1.1.4 | G | ||||||||||||||
| 172 | 02 83 00 | 03 | Product Data | Pressure Differential Automatic Recording Instrument | 3.1.1.4 | G | ||||||||||||||
| 173 | 02 83 00 | 03 | Product Data | Pressure Differential Log | 3.1.1.5 | G | ||||||||||||||
| 174 | 02 83 00 | 06 | Test Reports | Occupational and Environmental Assessment Data Report | 1.5.2.3 | G | ||||||||||||||
| 175 | 02 83 00 | 06 | Test Reports | Sampling Results | 1.5.2.3 | G | ||||||||||||||
| 176 | 02 83 00 | 06 | Test Reports | Pressure Differential Recordings For Local Exhaust System | 1.5.3 | G | ||||||||||||||
| 177 | 02 83 00 | 07 | Certificates | Testing Laboratory | 1.5.1.3 | G | ||||||||||||||
| 178 | 02 83 00 | 07 | Certificates | Third Party Consultant Qualifications | 0 | G | ||||||||||||||
| 179 | 02 83 00 | 07 | Certificates | Notification of the Commencement of Hazard Abatement | 0 | G | ||||||||||||||
| 180 | 02 83 00 | 07 | Certificates | Clearance Certification | 0 | G | ||||||||||||||
| 181 | 02 83 00 | 11 | Closeout Submittals | Hazardous Waste Manifest | 3.5.1.1 | G | ||||||||||||||
| 182 | 02 83 13.00 20 | 01 | Preconstruction Submittals | Occupational and Environmental Assessment Data Report | 1.5.2.3 | |||||||||||||||
| 183 | 02 83 13.00 20 | 01 | Preconstruction Submittals | Lead Compliance Plan | 1.5.2.2 | G | ||||||||||||||
| 184 | 02 83 13.00 20 | 01 | Preconstruction Submittals | Competent Person | 1.5.1.1 | |||||||||||||||
| 185 | 02 83 13.00 20 | 01 | Preconstruction Submittals | Training Certification | 1.5.1.2 | |||||||||||||||
| 186 | 02 83 13.00 20 | 01 | Preconstruction Submittals | Lead Waste Management Plan | 0 | G | ||||||||||||||
| 187 | 02 83 13.00 20 | 01 | Preconstruction Submittals | Medical Examinations | 1.5.2.4 | |||||||||||||||
| 188 | 02 83 13.00 20 | 06 | Test Reports | Sampling Results | 1.5.2.3 | |||||||||||||||
| 189 | 02 83 13.00 20 | 06 | Test Reports | Occupational and Environmental Assessment Data Report | 1.5.2.3 | |||||||||||||||
| 190 | 02 83 13.00 20 | 07 | Certificates | Testing Laboratory | 1.5.1.3 | |||||||||||||||
| 191 | 02 83 13.00 20 | 07 | Certificates | Occupant Notification | 3.1.1.1 | |||||||||||||||
| 192 | 02 83 13.00 20 | 07 | Certificates | Third Party Consultant Qualifications | 1.5.1.4 | |||||||||||||||
| 193 | 02 83 13.00 20 | 11 | Closeout Submittals | hazardous waste manifest | 3.5.2.1 | G | ||||||||||||||
| 194 | 02 83 13.00 20 | 11 | Closeout Submittals | turn-in documents or weight tickets | 3.5.2.1 | G | ||||||||||||||
| 195 | 02 84 16 | 07 | Certificates | Qualifications of CIH | 1.8.1 | G | ||||||||||||||
| 196 | 02 84 16 | 07 | Certificates | Training Certification | 1.8.1 | G | ||||||||||||||
| 197 | 02 84 16 | 07 | Certificates | PCB and Lamp Removal Work Plan | 1.8.2 | G | ||||||||||||||
| 198 | 02 84 16 | 07 | Certificates | PCB and Lamp Disposal Plan | 1.8.3 | G | ||||||||||||||
| 199 | 02 84 16 | 11 | Closeout Submittals | Transporter certification | 3.5.2 | G | ||||||||||||||
| 200 | 02 84 16 | 11 | Closeout Submittals | Certification of Decontamination | 3.2.4 | |||||||||||||||
| 201 | 02 84 16 | 11 | Closeout Submittals | Certificate of Disposal and/or recycling | 3.5.2.1 | |||||||||||||||
| 202 | 02 84 16 | 11 | Closeout Submittals | DD Form 1348-1 | 0 | |||||||||||||||
| 203 | 02 84 16 | 11 | Closeout Submittals | Testing results | 0 | |||||||||||||||
| 204 | 03 30 00 | 03 | Product Data | Joint Sealants | 2.4.7 | |||||||||||||||
| 205 | 03 30 00 | 03 | Product Data | Joint Filler | 2.4.6 | |||||||||||||||
| 206 | 03 30 00 | 03 | Product Data | Cementitious Materials | 2.4.1 | |||||||||||||||
| 207 | 03 30 00 | 03 | Product Data | Vapor Retarder | 2.4.5 | |||||||||||||||
| 208 | 03 30 00 | 03 | Product Data | Concrete Curing Materials | 2.3.3 | |||||||||||||||
| 209 | 03 30 00 | 03 | Product Data | Reinforcement | 2.5 | |||||||||||||||
| 210 | 03 30 00 | 03 | Product Data | Liquid Chemical Floor Hardener | 2.6.1 | |||||||||||||||
| 211 | 03 30 00 | 03 | Product Data | Admixtures | 2.4.4 | |||||||||||||||
| 212 | 03 30 00 | 03 | Product Data | Waterstops | 2.2.1 | |||||||||||||||
| 213 | 03 30 00 | 05 | Design Data | Mix Design | 2.3.1 | G | ||||||||||||||
| 214 | 03 30 00 | 06 | Test Reports | Concrete Mix Design | 1.6.1.1 | G | ||||||||||||||
| 215 | 03 30 00 | 06 | Test Reports | Aggregates | 2.4.3 | |||||||||||||||
| 216 | 03 30 00 | 06 | Test Reports | Compressive Strength Tests | 3.13.2.3 | G | ||||||||||||||
| 217 | 03 30 00 | 06 | Test Reports | Slump Tests | 3.13.2.1 | |||||||||||||||
| 218 | 03 30 00 | 07 | Certificates | Reinforcing Bars | 2.5.1 | |||||||||||||||
| 219 | 03 30 00 | 07 | Certificates | Safety Data Sheets | 0 | |||||||||||||||
| 220 | 03 30 00 | 07 | Certificates | Field Testing Technician and Testing Agency | 1.6.3.1 | |||||||||||||||
| 221 | 03 30 00 | 08 | Manufacturer’s Instructions | Liquid Chemical Floor Hardener | 2.6.1 | |||||||||||||||
| 222 | 03 30 00 | 08 | Manufacturer’s Instructions | Curing Compound | 2.3.3 | |||||||||||||||
| 223 | 04 20 00 | 03 | Product Data | Cementitious Materials | 2.4.1.1 | |||||||||||||||
| 224 | 04 20 00 | 03 | Product Data | Concrete Masonry Units (CMU) | 2.2.2.1 | G | ||||||||||||||
| 225 | 04 20 00 | 03 | Product Data | Admixtures for Masonry Mortar | 2.4.1.2 | |||||||||||||||
| 226 | 04 20 00 | 05 | Design Data | Masonry Compressive Strength | 2.1.2 | G | ||||||||||||||
| 227 | 04 20 00 | 06 | Test Reports | Field Testing of Mortar | 3.6.1.1 | G | ||||||||||||||
| 228 | 04 20 00 | 06 | Test Reports | Field Testing of Grout | 3.6.1.2 | G | ||||||||||||||
| 229 | 04 20 00 | 11 | Closeout Submittals | Recycled Content | 2.2.2.1.2 | S | ||||||||||||||
| 230 | 05 12 00 | 02 | Shop Drawings | Fabrication Drawings | 1.3.1 | G | ||||||||||||||
| 231 | 05 12 00 | 03 | Product Data | Shop Primer | 2.5.2 | |||||||||||||||
| 232 | 05 12 00 | 03 | Product Data | Welding Electrodes and Rods | 2.4.1 | |||||||||||||||
| 233 | 05 12 00 | 03 | Product Data | Direct Tension Indicator Washers | 0 | |||||||||||||||
| 234 | 05 12 00 | 03 | Product Data | Tension Control Bolts | 2.3.3 | |||||||||||||||
| 235 | 05 12 00 | 03 | Product Data | Recycled Content for Structural Steel | 2.2.1 | S | ||||||||||||||
| 236 | 05 12 00 | 03 | Product Data | Recycled Content for Structural Steel Tubing | 2.2.2 | S | ||||||||||||||
| 237 | 05 12 00 | 06 | Test Reports | Bolts, Nuts, and Washers | 2.3 | S | ||||||||||||||
| 238 | 05 12 00 | 06 | Test Reports | Weld Inspection Reports | 0 | S | ||||||||||||||
| 239 | 05 12 00 | 06 | Test Reports | Bolt Testing Reports | 3.6.2.1 | S | ||||||||||||||
| 240 | 05 12 00 | 07 | Certificates | Steel | 2.2 | |||||||||||||||
| 241 | 05 12 00 | 07 | Certificates | Bolts, Nuts, and Washers | 2.3 | |||||||||||||||
| 242 | 05 12 00 | 07 | Certificates | Welding Procedures and Qualifications | 1.3.2.1 | |||||||||||||||
| 243 | 05 12 00 | 07 | Certificates | Welding Electrodes and Rods | 2.4.1 | |||||||||||||||
| 244 | 05 12 00 | 07 | Certificates | Certified Welding Inspector | 3.6.1.1 | |||||||||||||||
| 245 | 05 12 00 | 07 | Certificates | NDT Technician | 0 | |||||||||||||||
| 246 | 05 12 00 | 07 | Certificates | Welding Procedure Specifications (WPS) | 3.4 | |||||||||||||||
| 247 | 06 10 00 | 02 | Shop Drawings | Modifications of Structural Members | 1.9.2 | G | ||||||||||||||
| 248 | 06 10 00 | 03 | Product Data | Structural-use plywood and OSB Panels | 0 | |||||||||||||||
| 249 | 06 10 00 | 03 | Product Data | Adhesives | 2.4.2 | |||||||||||||||
| 250 | 06 41 16 | 02 | Shop Drawings | Shop Drawings | 2.10 | G | ||||||||||||||
| 251 | 06 41 16 | 02 | Shop Drawings | Installation | 3.1 | |||||||||||||||
| 252 | 06 41 16 | 03 | Product Data | Wood Materials | 2.2 | S | ||||||||||||||
| 253 | 06 41 16 | 03 | Product Data | Wood Finishes | 0 | S | ||||||||||||||
| 254 | 06 41 16 | 03 | Product Data | Recycled Content | 2.1.3 | S | ||||||||||||||
| 255 | 06 61 16 | 02 | Shop Drawings | Detail Drawings | 0 | G | ||||||||||||||
| 256 | 06 61 16 | 03 | Product Data | Solid Polymer Material | 2.2 | |||||||||||||||
| 257 | 06 61 16 | 03 | Product Data | Qualifications | 1.5.1 | |||||||||||||||
| 258 | 07 05 23 | 01 | Preconstruction Submittals | Work Plan | 1.4 | G | ||||||||||||||
| 259 | 07 05 23 | 03 | Product Data | Thermal Imaging Camera | 2.2 | |||||||||||||||
| 260 | 07 05 23 | 05 | Design Data | Envelope Surface Area Calculations | 3.2 | |||||||||||||||
| 261 | 07 05 23 | 07 | Certificates | Pressure Test Agency | 1.6.2.1 | |||||||||||||||
| 262 | 07 05 23 | 07 | Certificates | Thermographer Qualifications | 1.6.2.2 | |||||||||||||||
| 263 | 07 05 23 | 07 | Certificates | Test Instruments | 1.6.3 | |||||||||||||||
| 264 | 07 05 23 | 07 | Certificates | Date Of Last Calibration | 1.6.3 | |||||||||||||||
| 265 | 07 05 23 | 06 | Test Reports | Pressure Test Procedures | 3.5 | |||||||||||||||
| 266 | 07 05 23 | 06 | Test Reports | Air Leakage Test Report | 3.5.6 | G S | ||||||||||||||
| 267 | 07 05 23 | 06 | Test Reports | Diagnostic Test Report | 3.6.4 | G S | ||||||||||||||
| 268 | 07 21 13 | 03 | Product Data | Manufacturer's Standard Details | 1.3 | |||||||||||||||
| 269 | 07 21 13 | 03 | Product Data | Block or Board Insulation | 2.1 | G | ||||||||||||||
| 270 | 07 21 13 | 03 | Product Data | Accessories | 2.3 | |||||||||||||||
| 271 | 07 21 13 | 03 | Product Data | Recycled Content for Block or Board Insulation | 2.1.4 | S | ||||||||||||||
| 272 | 07 21 13 | 08 | Manufacturer’s Instructions | Block or Board Insulation | 2.1 | |||||||||||||||
| 273 | 07 21 13 | 08 | Manufacturer’s Instructions | Adhesive | 2.3.1 | |||||||||||||||
| 274 | 07 21 16 | 03 | Product Data | Blanket Insulation | 2.1 | G | ||||||||||||||
| 275 | 07 21 16 | 03 | Product Data | Vapor Retarder | 2.4 | G | ||||||||||||||
| 276 | 07 21 16 | 03 | Product Data | Accessories | 2.6 | |||||||||||||||
| 277 | 07 21 16 | 08 | Manufacturer’s Instructions | Insulation | 3.3.1 | |||||||||||||||
| 278 | 07 22 00 | 03 | Product Data | Cover Board | 2.3 | |||||||||||||||
| 279 | 07 22 00 | 03 | Product Data | Fasteners | 2.5 | |||||||||||||||
| 280 | 07 22 00 | 03 | Product Data | Moisture Control | 2.4 | G | ||||||||||||||
| 281 | 07 22 00 | 03 | Product Data | Insulation | 2.2 | G S | ||||||||||||||
| 282 | 07 22 00 | 06 | Test Reports | Flame Spread Rating | 1.6.1 | |||||||||||||||
| 283 | 07 25 00 | 03 | Product Data | Material Characteristics | 0 | |||||||||||||||
| 284 | 07 25 00 | 07 | Certificates | ABAA Manufacturer Qualification | 0 | |||||||||||||||
| 285 | 07 27 10 | 04 | Samples | Mock-Up | 3.1.2 | G | ||||||||||||||
| 286 | 07 27 10 | 06 | Test Reports | Design Review Report | 1.8 | |||||||||||||||
| 287 | 07 27 10 | 06 | Test Reports | Testing and Inspection | 3.1.3 | G | ||||||||||||||
| 288 | 07 27 10 | 07 | Certificates | Air Barrier Inspector | 1.7 | G | ||||||||||||||
| 289 | 07 27 19.01 | 03 | Product Data | Self-adhering Air Barrier | 2.1 | G | ||||||||||||||
| 290 | 07 27 19.01 | 03 | Product Data | Primers, Adhesives, and Mastics | 2.2 | |||||||||||||||
| 291 | 07 27 19.01 | 03 | Product Data | Safety Data Sheets | 1.3.1 | |||||||||||||||
| 292 | 07 41 13 | 02 | Shop Drawings | Roofing Panels | 0 | G | ||||||||||||||
| 293 | 07 41 13 | 03 | Product Data | Roof Panels | 2.1 | G S | ||||||||||||||
| 294 | 07 41 13 | 03 | Product Data | Fasteners | 0 | |||||||||||||||
| 295 | 07 41 13 | 03 | Product Data | Underlayments | 2.7 | G | ||||||||||||||
| 296 | 07 41 13 | 03 | Product Data | Solar Reflectance Index (SRI) | 2.2 | S | ||||||||||||||
| 297 | 07 41 13 | 04 | Samples | Factory-applied Color Finish | 0 | G | ||||||||||||||
| 298 | 07 41 13 | 05 | Design Data | Wind Uplift Resistance | 1.2.1.2 | |||||||||||||||
| 299 | 07 41 13 | 11 | Closeout Submittals | Manufacturer's Warranties | 0 | |||||||||||||||
| 300 | 07 41 13 | 11 | Closeout Submittals | Contractor's Warranty | 0 | |||||||||||||||
| 301 | 07 42 13 | 02 | Shop Drawings | Installation Drawings | 0 | G | ||||||||||||||
| 302 | 07 42 13 | 03 | Product Data | Metal Wall Panels | 3.1 | G S | ||||||||||||||
| 303 | 07 42 13 | 03 | Product Data | Factory Color Finish | 2.2.2 | G | ||||||||||||||
| 304 | 07 42 13 | 03 | Product Data | Accessories | 2.5 | |||||||||||||||
| 305 | 07 42 13 | 11 | Closeout Submittals | Warranty | 1.7 | |||||||||||||||
| 306 | 07 53 23 | 02 | Shop Drawings | Roof Plan Drawing | 1.3.1 | G | ||||||||||||||
| 307 | 07 53 23 | 03 | Product Data | EPDM Sheet | 2.1.1 | G | ||||||||||||||
| 308 | 07 53 23 | 03 | Product Data | Roof Insulation | 0 | G | ||||||||||||||
| 309 | 07 53 23 | 03 | Product Data | warranty | 1.8 | |||||||||||||||
| 310 | 07 53 23 | 05 | Design Data | Wind Uplift Calculations | 1.4.4 | |||||||||||||||
| 311 | 07 53 23 | 11 | Closeout Submittals | Warranty | 1.8 | |||||||||||||||
| 312 | 07 60 00 | 02 | Shop Drawings | Flashing | 0 | G | ||||||||||||||
| 313 | 07 60 00 | 03 | Product Data | Vinyl bird mitigation | 0 | G | ||||||||||||||
| 314 | 07 60 00 | 04 | Samples | Finish Samples | 1.4.2 | G | ||||||||||||||
| 315 | 07 84 00 | 02 | Shop Drawings | Firestopping System | 0 | |||||||||||||||
| 316 | 07 84 00 | 03 | Product Data | Firestopping Materials | 2.2 | G S | ||||||||||||||
| 317 | 07 92 00 | 03 | Product Data | Sealants | 2.2 | S | ||||||||||||||
| 318 | 07 92 00 | 03 | Product Data | Primers | 2.3 | |||||||||||||||
| 319 | 07 92 00 | 03 | Product Data | Bond Breakers | 2.4 | |||||||||||||||
| 320 | 07 92 00 | 03 | Product Data | Backstops | 2.5 | |||||||||||||||
| 321 | 08 11 13 | 02 | Shop Drawings | Doors | 0 | G | ||||||||||||||
| 322 | 08 11 13 | 02 | Shop Drawings | Frames | 0 | G | ||||||||||||||
| 323 | 08 14 00 | 02 | Shop Drawings | Doors | 2.2 | G | ||||||||||||||
| 324 | 08 14 00 | 03 | Product Data | Doors | 2.2 | G | ||||||||||||||
| 325 | 08 14 00 | 03 | Product Data | Accessories | 2.3 | |||||||||||||||
| 326 | 08 14 00 | 03 | Product Data | Warranty | 1.5 | |||||||||||||||
| 327 | 08 14 00 | 03 | Product Data | Composite Wood and Agrifiber Materials | 0 | S | ||||||||||||||
| 328 | 08 14 00 | 03 | Product Data | Wood Finishes | 0 | S | ||||||||||||||
| 329 | 08 31 00 | 02 | Shop Drawings | Access Doors And Panels | 1.3 | |||||||||||||||
| 330 | 08 31 00 | 03 | Product Data | Access Doors And Panels | 1.3 | G | ||||||||||||||
| 331 | 08 31 00 | 03 | Product Data | Hardware | 1.3.1 | |||||||||||||||
| 332 | 08 31 00 | 03 | Product Data | Accessories | 2.1.7 | |||||||||||||||
| 333 | 08 54 13 | 02 | Shop Drawings | Shop Drawings | 0 | G | ||||||||||||||
| 334 | 08 54 13 | 03 | Product Data | Finish | 2.4 | G | ||||||||||||||
| 335 | 08 54 13 | 03 | Product Data | Low Profile (LP) fixed Window | 0 | G | ||||||||||||||
| 336 | 08 54 13 | 03 | Product Data | VOC Content | 0 | |||||||||||||||
| 337 | 08 54 13 | 03 | Product Data | U-Factor and structural rating charts | 0 | |||||||||||||||
| 338 | 08 54 13 | 04 | Samples | Color | 0 | G | ||||||||||||||
| 339 | 08 54 13 | 04 | Samples | Glass | 0 | |||||||||||||||
| 340 | 08 54 13 | 08 | Manufacturer’s Instructions | Installation Instructions | 0 | |||||||||||||||
| 341 | 08 54 13 | 11 | Closeout Submittals | Maintenance Instructions | 0 | |||||||||||||||
| 342 | 08 54 13 | 11 | Closeout Submittals | Special Warranties | 0 | |||||||||||||||
| 343 | 08 71 00 | 02 | Shop Drawings | Manufacturer's Detail Drawings | 1.3 | G | ||||||||||||||
| 344 | 08 71 00 | 02 | Shop Drawings | Hardware Schedule | 1.5 | G | ||||||||||||||
| 345 | 08 71 00 | 02 | Shop Drawings | Keying System | 2.3.6 | G | ||||||||||||||
| 346 | 08 71 00 | 03 | Product Data | Hardware Items | 2.3 | G | ||||||||||||||
| 347 | 08 71 00 | 08 | Manufacturer’s Instructions | Installation | 3.1 | |||||||||||||||
| 348 | 08 71 00 | 10 | Operation and Maintenance Data | Hardware Schedule | 1.5 | G | ||||||||||||||
| 349 | 08 71 00 | 11 | Closeout Submittals | Key Bitting | 1.6.1 | |||||||||||||||
| 350 | 09 29 00 | 03 | Product Data | Water-Resistant Gypsum Backing Board | 2.2.2 | |||||||||||||||
| 351 | 09 29 00 | 03 | Product Data | Accessories | 2.2.7 | |||||||||||||||
| 352 | 09 29 00 | 03 | Product Data | Gypsum Board | 2.2.1 | |||||||||||||||
| 353 | 09 29 00 | 11 | Closeout Submittals | Recycled Content for Gypsum Board | 0 | S | ||||||||||||||
| 354 | 09 29 00 | 11 | Closeout Submittals | VOC Content of Joint Compound | 2.2.4 | S | ||||||||||||||
| 355 | 09 51 00 | 03 | Product Data | Acoustical Ceiling Systems | 0 | G | ||||||||||||||
| 356 | 09 62 38 | 03 | Product Data | Static-Control Resilient Flooring | 2.1 | G S | ||||||||||||||
| 357 | 09 62 38 | 03 | Product Data | Adhesives | 0 | S | ||||||||||||||
| 358 | 09 62 38 | 04 | Samples | Static-Control Resilient Flooring | 2.1 | G | ||||||||||||||
| 359 | 09 62 38 | 11 | Closeout Submittals | Recycled content for Conductive Rubber Tile | 0 | S | ||||||||||||||
| 360 | 09 65 00 | 03 | Product Data | Resilient Flooring and Accessories | 2.8 | G | ||||||||||||||
| 361 | 09 65 00 | 03 | Product Data | Adhesives | 2.6 | |||||||||||||||
| 362 | 09 65 00 | 04 | Samples | Resilient Flooring and Accessories | 2.8 | G | ||||||||||||||
| 363 | 09 68 00 | 03 | Product Data | Entrance Carpet | 2.1 | G | ||||||||||||||
| 364 | 09 68 00 | 03 | Product Data | Adhesives | 0 | |||||||||||||||
| 365 | 09 68 00 | 04 | Samples | Carpet | 0 | G | ||||||||||||||
| 366 | 09 90 00 | 03 | Product Data | Coating | 2.1 | |||||||||||||||
| 367 | 09 90 00 | 03 | Product Data | Manufacturer's Technical Data Sheets | 2.1 | |||||||||||||||
| 368 | 09 90 00 | 04 | Samples | Color | 1.8 | G | ||||||||||||||
| 369 | 10 14 00.10 | 02 | Shop Drawings | Approved Detail Drawings | 3.1 | G | ||||||||||||||
| 370 | 10 14 00.10 | 03 | Product Data | Installation | 3.1 | |||||||||||||||
| 371 | 10 14 00.10 | 03 | Product Data | Exterior Signage | 1.2 | G | ||||||||||||||
| 372 | 10 14 00.20 | 02 | Shop Drawings | Detail Drawings | 1.3.1 | G | ||||||||||||||
| 373 | 10 14 00.20 | 03 | Product Data | Warranty | 1.5 | |||||||||||||||
| 374 | 10 26 00 | 03 | Product Data | Fiberglass Reinforced Panels | 0 | G | ||||||||||||||
| 375 | 10 26 00 | 04 | Samples | Finish | 2.4 | |||||||||||||||
| 376 | 10 28 13 | 03 | Product Data | Finishes | 2.1.2 | G | ||||||||||||||
| 377 | 10 28 13 | 03 | Product Data | Accessory Items | 2.2 | G | ||||||||||||||
| 378 | 12 21 00 | 02 | Shop Drawings | Installation | 3.2 | G | ||||||||||||||
| 379 | 13 48 00 | 02 | Shop Drawings | Bracing | 3.1 | |||||||||||||||
| 380 | 13 48 00 | 02 | Shop Drawings | Equipment Requirements | 2.1 | |||||||||||||||
| 381 | 13 48 00 | 03 | Product Data | Bracing | 3.1 | |||||||||||||||
| 382 | 13 48 00 | 03 | Product Data | Equipment Requirements | 2.1 | |||||||||||||||
| 383 | 13 48 00 | 03 | Product Data | Anchor Bolts | 3.3 | |||||||||||||||
| 384 | 13 48 00 | 06 | Test Reports | Anchor Bolts | 3.3 | |||||||||||||||
| 385 | 21 13 13.00 10 | 02 | Shop Drawings | Shop Drawings | 1.4.3 | G | ||||||||||||||
| 386 | 21 13 13.00 10 | 02 | Shop Drawings | As-Built Drawings | 3.7 | G | ||||||||||||||
| 387 | 21 13 13.00 10 | 03 | Product Data | Fire Protection Related Submittals | 1.4.1 | G | ||||||||||||||
| 388 | 21 13 13.00 10 | 03 | Product Data | Materials and Equipment | 2.3 | G | ||||||||||||||
| 389 | 21 13 13.00 10 | 03 | Product Data | Spare Parts | 1.6 | |||||||||||||||
| 390 | 21 13 13.00 10 | 03 | Product Data | Preliminary Tests | 3.6 | G | ||||||||||||||
| 391 | 21 13 13.00 10 | 03 | Product Data | Final Acceptance Test | 3.7 | G | ||||||||||||||
| 392 | 21 13 13.00 10 | 03 | Product Data | Onsite Training | 3.8 | |||||||||||||||
| 393 | 21 13 13.00 10 | 03 | Product Data | Fire Protection Specialist | 1.4.1 | |||||||||||||||
| 394 | 21 13 13.00 10 | 03 | Product Data | Sprinkler System Installer | 1.4.2 | |||||||||||||||
| 395 | 21 13 13.00 10 | 05 | Design Data | Sway Bracing | 1.4.3 | |||||||||||||||
| 396 | 21 13 13.00 10 | 05 | Design Data | Hydraulic Calculations | 1.2.1.3 | |||||||||||||||
| 397 | 21 13 13.00 10 | 06 | Test Reports | Preliminary Test Report | 3.6 | G | ||||||||||||||
| 398 | 21 13 13.00 10 | 06 | Test Reports | Final Acceptance Test Report | 3.7 | G | ||||||||||||||
| 399 | 21 13 13.00 10 | 07 | Certificates | Inspection by Fire Protection Specialist | 3.3 | G | ||||||||||||||
| 400 | 21 13 13.00 10 | 10 | Operation and Maintenance Data | Operating and Maintenance Manuals | 3.8 | G | ||||||||||||||
| 401 | 21 30 00 | 01 | Preconstruction Submittals | Fire Pump Installation Related Submittals | 1.3 | |||||||||||||||
| 402 | 21 30 00 | 01 | Preconstruction Submittals | Fire Protection Specialist | 1.7.1 | |||||||||||||||
| 403 | 21 30 00 | 02 | Shop Drawings | Installation Drawings | 3.3.1 | G | ||||||||||||||
| 404 | 21 30 00 | 02 | Shop Drawings | As-Built Drawings | 3.9.2 | G | ||||||||||||||
| 405 | 21 30 00 | 02 | Shop Drawings | Piping Layout | 3.3.2 | G | ||||||||||||||
| 406 | 21 30 00 | 02 | Shop Drawings | Pump Room | 3.3.2 | G | ||||||||||||||
| 407 | 21 30 00 | 03 | Product Data | Catalog Data | 2.1 | G | ||||||||||||||
| 408 | 21 30 00 | 03 | Product Data | Spare Parts | 1.6 | |||||||||||||||
| 409 | 21 30 00 | 03 | Product Data | Preliminary Tests | 3.7.2 | G | ||||||||||||||
| 410 | 21 30 00 | 03 | Product Data | Field Tests | 3.7 | G | ||||||||||||||
| 411 | 21 30 00 | 03 | Product Data | Manufacturer's Representative | 1.7.6 | |||||||||||||||
| 412 | 21 30 00 | 03 | Product Data | Field Training | 3.9.1 | |||||||||||||||
| 413 | 21 30 00 | 06 | Test Reports | Preliminary Tests | 3.7.2 | G | ||||||||||||||
| 414 | 21 30 00 | 07 | Certificates | Fire Protection Specialist | 1.7.1 | |||||||||||||||
| 415 | 21 30 00 | 07 | Certificates | Qualifications of Welders | 1.7.2 | |||||||||||||||
| 416 | 21 30 00 | 07 | Certificates | Qualifications of Installer | 1.7.3 | |||||||||||||||
| 417 | 21 30 00 | 07 | Certificates | Preliminary Test Certification | 1.7.4 | G | ||||||||||||||
| 418 | 21 30 00 | 07 | Certificates | Final Test Certification | 1.7.5 | G | ||||||||||||||
| 419 | 21 30 00 | 10 | Operation and Maintenance Data | Operating and Maintenance Instructions | 3.9.1 | G | ||||||||||||||
| 420 | 21 30 00 | 10 | Operation and Maintenance Data | Flow Meter | 2.12 | G | ||||||||||||||
| 421 | 22 00 00 | 02 | Shop Drawings | Plumbing System | 3.8.1 | G | ||||||||||||||
| 422 | 22 00 00 | 03 | Product Data | Fixtures | 2.4 | G | ||||||||||||||
| 423 | 22 00 00 | 03 | Product Data | Flush Valve Water Closets | 2.4.1 | G | ||||||||||||||
| 424 | 22 00 00 | 03 | Product Data | WaterSense Label for Flush Valve Water Closet | 2.4.1 | S | ||||||||||||||
| 425 | 22 00 00 | 03 | Product Data | Wall Hung Lavatories | 2.4.2 | G | ||||||||||||||
| 426 | 22 00 00 | 03 | Product Data | WaterSense Label for Lavatory Faucet | 0 | S | ||||||||||||||
| 427 | 22 00 00 | 03 | Product Data | Service Sinks | 2.4.3 | G | ||||||||||||||
| 428 | 22 00 00 | 03 | Product Data | Water Heaters | 2.8 | G | ||||||||||||||
| 429 | 22 00 00 | 03 | Product Data | Pumps | 2.9 | G | ||||||||||||||
| 430 | 22 00 00 | 03 | Product Data | Backflow Prevention Assemblies | 3.8.1.1 | G | ||||||||||||||
| 431 | 22 00 00 | 03 | Product Data | Welding | 1.5.1 | |||||||||||||||
| 432 | 22 00 00 | 03 | Product Data | Plumbing System | 3.8.1 | G | ||||||||||||||
| 433 | 22 00 00 | 06 | Test Reports | Tests, Flushing and Disinfection | 3.8 | G | ||||||||||||||
| 434 | 22 00 00 | 06 | Test Reports | Test of Backflow Prevention Assemblies | 3.8.1.1 | G | ||||||||||||||
| 435 | 22 00 00 | 07 | Certificates | Materials and Equipment | 1.3 | |||||||||||||||
| 436 | 22 00 00 | 07 | Certificates | Bolts | 2.1.1 | |||||||||||||||
| 437 | 22 00 00 | 10 | Operation and Maintenance Data | Plumbing System | 3.8.1 | |||||||||||||||
| 438 | 22 07 19.00 40 | 03 | Product Data | Adhesives and Sealants | 2.3 | S | ||||||||||||||
| 439 | 22 07 19.00 40 | 03 | Product Data | Coatings | 2.3 | S | ||||||||||||||
| 440 | 22 07 19.00 40 | 03 | Product Data | Insulating Cement | 2.3 | |||||||||||||||
| 441 | 22 07 19.00 40 | 03 | Product Data | Insulation Materials | 2.3 | G | ||||||||||||||
| 442 | 22 07 19.00 40 | 03 | Product Data | Jacketing | 2.3 | G | ||||||||||||||
| 443 | 23 00 00 | 02 | Shop Drawings | Detail Drawings | 1.4.4 | G | ||||||||||||||
| 444 | 23 00 00 | 03 | Product Data | Metallic Flexible Duct | 2.9.1.1 | G | ||||||||||||||
| 445 | 23 00 00 | 03 | Product Data | Insulated Nonmetallic Flexible Duct Runouts | 2.9.1.2 | G | ||||||||||||||
| 446 | 23 00 00 | 03 | Product Data | Duct Connectors | 2.9.1.2 | |||||||||||||||
| 447 | 23 00 00 | 03 | Product Data | Duct Access Doors | 2.9.2 | |||||||||||||||
| 448 | 23 00 00 | 03 | Product Data | Fire Dampers | 2.9.3 | G | ||||||||||||||
| 449 | 23 00 00 | 03 | Product Data | Manual Balancing Dampers | 2.9.4 | G | ||||||||||||||
| 450 | 23 00 00 | 03 | Product Data | Sound Attenuation Equipment | 2.9.8 | G | ||||||||||||||
| 451 | 23 00 00 | 03 | Product Data | Diffusers | 2.9.9.1 | G | ||||||||||||||
| 452 | 23 00 00 | 03 | Product Data | Registers and Grilles | 2.9.9.2 | G | ||||||||||||||
| 453 | 23 00 00 | 03 | Product Data | Louvers | 2.9.10 | G | ||||||||||||||
| 454 | 23 00 00 | 03 | Product Data | Air Vents, Penthouses, and Goosenecks | 2.9.11 | G | ||||||||||||||
| 455 | 23 00 00 | 03 | Product Data | Ceiling Exhaust Fans | 0 | G | ||||||||||||||
| 456 | 23 00 00 | 03 | Product Data | Energy Star label for ceiling exhaust fan product | 0 | S | ||||||||||||||
| 457 | 23 00 00 | 03 | Product Data | Air Handling Units | 2.11 | G | ||||||||||||||
| 458 | 23 00 00 | 03 | Product Data | Test Procedures | 1.4.5 | G | ||||||||||||||
| 459 | 23 00 00 | 03 | Product Data | Diagrams | 1.2.1.2 | |||||||||||||||
| 460 | 23 00 00 | 03 | Product Data | Indoor Air Quality for Duct Sealants | 2.9.1 | S | ||||||||||||||
| 461 | 23 00 00 | 06 | Test Reports | Performance Tests | 3.9 | G | ||||||||||||||
| 462 | 23 00 00 | 06 | Test Reports | Damper Acceptance Test | 0 | |||||||||||||||
| 463 | 23 00 00 | 07 | Certificates | Bolts | 0 | |||||||||||||||
| 464 | 23 00 00 | 07 | Certificates | Ozone Depleting Substances Technician Certification | 1.4.3 | |||||||||||||||
| 465 | 23 00 00 | 08 | Manufacturer’s Instructions | Manufacturer's Installation Instructions | 3.2 | |||||||||||||||
| 466 | 23 00 00 | 08 | Manufacturer’s Instructions | Operation and Maintenance Training | 3.11.2 | |||||||||||||||
| 467 | 23 00 00 | 10 | Operation and Maintenance Data | Operation and Maintenance Manuals | 3.11.1 | G | ||||||||||||||
| 468 | 23 00 00 | 10 | Operation and Maintenance Data | Fire Dampers | 2.9.3 | G | ||||||||||||||
| 469 | 23 00 00 | 10 | Operation and Maintenance Data | Manual Balancing Dampers | 2.9.4 | G | ||||||||||||||
| 470 | 23 00 00 | 10 | Operation and Maintenance Data | Automatic Smoke-Fire Dampers | 0 | G | ||||||||||||||
| 471 | 23 00 00 | 10 | Operation and Maintenance Data | Air Handling Units | 2.11 | G | ||||||||||||||
| 472 | 23 00 00 | 11 | Closeout Submittals | Indoor Air Quality During Construction | 3.10 | G S | ||||||||||||||
| 473 | 23 05 15 | 03 | Product Data | Piping Specialties | 2.4 | G | ||||||||||||||
| 474 | 23 05 15 | 03 | Product Data | Valves | 2.5 | G | ||||||||||||||
| 475 | 23 05 15 | 03 | Product Data | Supporting Elements | 2.8 | |||||||||||||||
| 476 | 23 05 15 | 03 | Product Data | Valve Application Schedule | 2.5 | |||||||||||||||
| 477 | 23 05 15 | 03 | Product Data | Hot Water Unit Heaters | 2.6.1 | G | ||||||||||||||
| 478 | 23 05 15 | 03 | Product Data | Hot Water Cabinet Unit Heaters | 2.6.2 | G | ||||||||||||||
| 479 | 23 05 15 | 03 | Product Data | Heating System Fluid | 2.1 | G | ||||||||||||||
| 480 | 23 05 15 | 03 | Product Data | Air Separator | 2.4.1 | G | ||||||||||||||
| 481 | 23 05 15 | 03 | Product Data | Diaphragm Expansion Tank | 2.4.3 | G | ||||||||||||||
| 482 | 23 05 15 | 04 | Samples | Manufacturer's Standard Color Charts | 2.6.2 | |||||||||||||||
| 483 | 23 05 15 | 10 | Operation and Maintenance Data | Operation and Maintenance Manuals | 3.12 | G | ||||||||||||||
| 484 | 23 05 48.19 | 02 | Shop Drawings | Bracing | 3.1 | G | ||||||||||||||
| 485 | 23 05 48.19 | 02 | Shop Drawings | Equipment Restraint | 2.2 | |||||||||||||||
| 486 | 23 05 48.19 | 02 | Shop Drawings | Contractor Designed Bracing | 1.2.4 | |||||||||||||||
| 487 | 23 05 48.19 | 03 | Product Data | Bracing | 3.1 | |||||||||||||||
| 488 | 23 05 48.19 | 03 | Product Data | Equipment Restraint | 2.2 | |||||||||||||||
| 489 | 23 05 48.19 | 03 | Product Data | Contractor Designed Bracing | 1.2.4 | |||||||||||||||
| 490 | 23 05 48.19 | 03 | Product Data | Anchor Bolts | 3.3 | |||||||||||||||
| 491 | 23 05 48.19 | 05 | Design Data | Design Calculations | 1.2.4 | |||||||||||||||
| 492 | 23 05 48.19 | 06 | Test Reports | Anchor Bolts | 3.3 | |||||||||||||||
| 493 | 23 05 93 | 01 | Preconstruction Submittals | Records of Existing Conditions | 0 | |||||||||||||||
| 494 | 23 05 93 | 02 | Shop Drawings | TAB Schematic Drawings and Report Forms | 1.3.3 | G | ||||||||||||||
| 495 | 23 05 93 | 03 | Product Data | Equipment and Performance Data | 1.3 | G | ||||||||||||||
| 496 | 23 05 93 | 03 | Product Data | TAB Related HVAC Submittals | 0 | G | ||||||||||||||
| 497 | 23 05 93 | 06 | Test Reports | Completed Pre-Final DALT Report | 0 | G | ||||||||||||||
| 498 | 23 05 93 | 06 | Test Reports | Certified Final DALT Report | 0 | G | ||||||||||||||
| 499 | 23 05 93 | 07 | Certificates | Independent TAB Agency and Personnel Qualifications | 1.5.1 | |||||||||||||||
| 500 | 23 05 93 | 07 | Certificates | DALT and TAB Submittal and Work Schedule | 0 | G | ||||||||||||||
| 501 | 23 05 93 | 07 | Certificates | TAB Pre-Field Engineering Report | 0 | G | ||||||||||||||
| 502 | 23 07 00 | 03 | Product Data | Pipe Insulation Systems | 2.4 | G | ||||||||||||||
| 503 | 23 07 00 | 03 | Product Data | Duct Insulation Systems | 3.3 | G | ||||||||||||||
| 504 | 23 07 00 | 03 | Product Data | Jackets | 2.3.8 | G | ||||||||||||||
| 505 | 23 07 00 | 11 | Closeout Submittals | Reduce Volatile Organic Compounds (VOC) | 2.1.1 | S | ||||||||||||||
| 506 | 23 21 23 | 03 | Product Data | Hydronic Pumps Equipment Data | 2.2.3 | G | ||||||||||||||
| 507 | 23 21 23 | 10 | Operation and Maintenance Data | Operation and Maintenance Manuals | 3.5.1 | G | ||||||||||||||
| 508 | 23 22 26.00 20 | 03 | Product Data | Valves | 2.1.2 | G | ||||||||||||||
| 509 | 23 22 26.00 20 | 03 | Product Data | Valve Operating Mechanism | 0 | G | ||||||||||||||
| 510 | 23 22 26.00 20 | 03 | Product Data | Condensate Meters | 0 | G | ||||||||||||||
| 511 | 23 22 26.00 20 | 03 | Product Data | Traps | 2.1.4.2 | G | ||||||||||||||
| 512 | 23 22 26.00 20 | 03 | Product Data | Strainers | 2.1.4.3 | G | ||||||||||||||
| 513 | 23 22 26.00 20 | 03 | Product Data | Flash Tanks | 2.1.4.5 | G | ||||||||||||||
| 514 | 23 22 26.00 20 | 03 | Product Data | Instrumentation | 2.1.3 | G | ||||||||||||||
| 515 | 23 22 26.00 20 | 03 | Product Data | Shell & Tube Heat Exchangers | 0 | G | ||||||||||||||
| 516 | 23 22 26.00 20 | 03 | Product Data | Condensate Return Pumping Units | 2.3.1 | G | ||||||||||||||
| 517 | 23 22 26.00 20 | 03 | Product Data | Pipe and Pipe System | 2.1 | G | ||||||||||||||
| 518 | 23 22 26.00 20 | 06 | Test Reports | Piping System | 0 | G | ||||||||||||||
| 519 | 23 22 26.00 20 | 06 | Test Reports | Valves | 2.1.2 | G | ||||||||||||||
| 520 | 23 22 26.00 20 | 06 | Test Reports | Instrumentation | 2.1.3 | G | ||||||||||||||
| 521 | 23 22 26.00 20 | 07 | Certificates | Welding Procedure | 1.4.1 | |||||||||||||||
| 522 | 23 22 26.00 20 | 07 | Certificates | Welder's Performance Qualification Record | 1.4.2 | |||||||||||||||
| 523 | 23 22 26.00 20 | 07 | Certificates | List of Welders and Welder's Symbols | 1.4.2 | |||||||||||||||
| 524 | 23 22 26.00 20 | 08 | Manufacturer’s Instructions | Condensate Return Pumping Units | 2.3.1 | |||||||||||||||
| 525 | 26 12 19.10 | 02 | Shop Drawings | Pad-mounted Transformer Drawings | 1.5.1 | G | ||||||||||||||
| 526 | 26 12 19.10 | 03 | Product Data | Pad-mounted Transformers | 2.2 | G | ||||||||||||||
| 527 | 26 12 19.10 | 06 | Test Reports | Acceptance Checks and Tests | 3.7.1 | G | ||||||||||||||
| 528 | 26 12 19.10 | 07 | Certificates | Transformer Efficiencies | 2.2.2.1 | |||||||||||||||
| 529 | 26 12 19.10 | 09 | Manufacturer’s Field Reports | Transformer Test Schedule | 2.7.1 | |||||||||||||||
| 530 | 26 12 19.10 | 10 | Operation and Maintenance Data | Transformer(s) | 1.6.1 | G | ||||||||||||||
| 531 | 26 20 00 | 02 | Shop Drawings | Panelboards | 2.11 | G | ||||||||||||||
| 532 | 26 20 00 | 02 | Shop Drawings | Transformers | 2.13 | G | ||||||||||||||
| 533 | 26 20 00 | 03 | Product Data | Receptacles | 2.10 | G | ||||||||||||||
| 534 | 26 20 00 | 03 | Product Data | Circuit breakers | 2.11.3 | G | ||||||||||||||
| 535 | 26 20 00 | 03 | Product Data | Switches | 2.8 | G | ||||||||||||||
| 536 | 26 20 00 | 03 | Product Data | Transformers | 2.13 | G | ||||||||||||||
| 537 | 26 20 00 | 03 | Product Data | Motor controllers | 2.15 | G | ||||||||||||||
| 538 | 26 20 00 | 03 | Product Data | Combination motor controllers | 0 | G | ||||||||||||||
| 539 | 26 20 00 | 03 | Product Data | Manual motor starters | 2.16 | G | ||||||||||||||
| 540 | 26 20 00 | 03 | Product Data | CATV outlets | 0 | G | ||||||||||||||
| 541 | 26 20 00 | 03 | Product Data | Grounding Busbar | 2.19.3 | G | ||||||||||||||
| 542 | 26 20 00 | 03 | Product Data | Surge protective devices | 2.25 | G | ||||||||||||||
| 543 | 26 20 00 | 06 | Test Reports | 600-volt wiring test | 3.5.2 | G | ||||||||||||||
| 544 | 26 20 00 | 06 | Test Reports | Grounding system test | 3.5.5 | G | ||||||||||||||
| 545 | 26 20 00 | 06 | Test Reports | Transformer tests | 3.5.3 | G | ||||||||||||||
| 546 | 26 20 00 | 06 | Test Reports | Ground-fault receptacle test | 3.5.4 | G | ||||||||||||||
| 547 | 26 20 00 | 07 | Certificates | Fuses | 2.9 | G | ||||||||||||||
| 548 | 26 20 00 | 09 | Manufacturer’s Field Reports | Transformer factory tests | 2.27.1 | G | ||||||||||||||
| 549 | 26 20 00 | 10 | Operation and Maintenance Data | Electrical Systems | 1.5.1 | G | ||||||||||||||
| 550 | 26 29 23 | 03 | Product Data | Variable Frequency Drives | 2.1 | G | ||||||||||||||
| 551 | 26 29 23 | 08 | Manufacturer’s Instructions | Installation instructions | 1.5.1 | |||||||||||||||
| 552 | 26 29 23 | 10 | Operation and Maintenance Data | Variable Frequency Drives | 2.1 | G | ||||||||||||||
| 553 | 26 51 00 | 03 | Product Data | Luminaires | 2.2 | G | ||||||||||||||
| 554 | 26 51 00 | 03 | Product Data | Vacancy Sensors | 2.5.3.2 | G | ||||||||||||||
| 555 | 26 51 00 | 03 | Product Data | Dimming Controllers (Dimmers) | 2.5.2 | G | ||||||||||||||
| 556 | 26 51 00 | 03 | Product Data | Exit Signs | 2.6.1 | G | ||||||||||||||
| 557 | 26 51 00 | 03 | Product Data | Occupancy Sensors | 2.5.3.1 | G | ||||||||||||||
| 558 | 27 10 00 | 03 | Product Data | Telecommunications cabling | 2.3 | G | ||||||||||||||
| 559 | 27 10 00 | 03 | Product Data | Patch panels | 2.4.5 | G | ||||||||||||||
| 560 | 27 10 00 | 03 | Product Data | Telecommunications outlet/connector assemblies | 2.5 | G | ||||||||||||||
| 561 | 27 10 00 | 03 | Product Data | Equipment support frame | 2.4.2 | |||||||||||||||
| 562 | 27 10 00 | 06 | Test Reports | Telecommunications cabling testing | 3.5.1 | G | ||||||||||||||
| 563 | 27 10 00 | 07 | Certificates | Telecommunications Contractor | 1.6.1.1 | |||||||||||||||
| 564 | 27 10 00 | 07 | Certificates | Key Personnel | 1.6.1.2 | |||||||||||||||
| 565 | 27 10 00 | 07 | Certificates | Manufacturer Qualifications | 1.6.1.3 | |||||||||||||||
| 566 | 27 10 00 | 07 | Certificates | Test plan | 1.6.2 | G | ||||||||||||||
| 567 | 27 10 00 | 09 | Manufacturer’s Field Reports | Factory reel tests | 2.10.1 | G | ||||||||||||||
| 568 | 27 10 00 | 10 | Operation and Maintenance Data | Telecommunications cabling and pathway system | 1.10.1 | G | ||||||||||||||
| 569 | 27 10 00 | 11 | Closeout Submittals | Record Documentation | 1.10.2 | |||||||||||||||
| 570 | 28 31 33.00 10 | 02 | Shop Drawings | Fire Alarm Reporting System | 0 | G | ||||||||||||||
| 571 | 28 31 33.00 10 | 02 | Shop Drawings | Wiring for Systems | 3.2.2 | G | ||||||||||||||
| 572 | 28 31 33.00 10 | 03 | Product Data | Battery | 2.3.2.1 | G | ||||||||||||||
| 573 | 28 31 33.00 10 | 03 | Product Data | Spare Parts | 0 | |||||||||||||||
| 574 | 28 31 33.00 10 | 03 | Product Data | Qualifications | 1.3 | |||||||||||||||
| 575 | 28 31 33.00 10 | 03 | Product Data | Training | 3.5 | |||||||||||||||
| 576 | 28 31 33.00 10 | 03 | Product Data | Test Procedures | 3.6 | G | ||||||||||||||
| 577 | 28 31 33.00 10 | 06 | Test Reports | Testing | 3.6 | G | ||||||||||||||
| 578 | 28 31 33.00 10 | 07 | Certificates | Equipment | 0 | |||||||||||||||
| 579 | 28 31 33.00 10 | 10 | Operation and Maintenance Data | Fire Alarm Reporting System | 0 | G | ||||||||||||||
| 580 | 28 31 76 | 02 | Shop Drawings | Wiring Diagrams | 3.2.1 | G | ||||||||||||||
| 581 | 28 31 76 | 02 | Shop Drawings | System Layout | 1.7 | G | ||||||||||||||
| 582 | 28 31 76 | 02 | Shop Drawings | System Operation | 2.3 | G | ||||||||||||||
| 583 | 28 31 76 | 02 | Shop Drawings | Notification Appliances | 2.15 | G | ||||||||||||||
| 584 | 28 31 76 | 03 | Product Data | Technical Data And Computer Software | 1.6 | G | ||||||||||||||
| 585 | 28 31 76 | 03 | Product Data | Fire Alarm Control Unit (FACU) | 2.12 | G | ||||||||||||||
| 586 | 28 31 76 | 03 | Product Data | LCD, LED Display Unit (VDU) | 0 | G | ||||||||||||||
| 587 | 28 31 76 | 03 | Product Data | Terminal Cabinets | 3.2.2 | G | ||||||||||||||
| 588 | 28 31 76 | 03 | Product Data | Manual Stations | 2.14 | G | ||||||||||||||
| 589 | 28 31 76 | 03 | Product Data | Transmitters | 2.17 | G | ||||||||||||||
| 590 | 28 31 76 | 03 | Product Data | Batteries | 2.11.1 | G | ||||||||||||||
| 591 | 28 31 76 | 03 | Product Data | Battery Chargers | 2.11.2 | G | ||||||||||||||
| 592 | 28 31 76 | 03 | Product Data | Smoke Sensors | 2.9 | G | ||||||||||||||
| 593 | 28 31 76 | 03 | Product Data | Notification Appliances | 2.15 | G | ||||||||||||||
| 594 | 28 31 76 | 03 | Product Data | Addressable Interface Devices | 2.6 | G | ||||||||||||||
| 595 | 28 31 76 | 03 | Product Data | Remote Fire Alarm Control Units | 0 | G | ||||||||||||||
| 596 | 28 31 76 | 03 | Product Data | Radio Transmitter and Interface Panels | 2.17.1 | G | ||||||||||||||
| 597 | 28 31 76 | 05 | Design Data | Battery Power | 2.11.1.2 | |||||||||||||||
| 598 | 28 31 76 | 05 | Design Data | Battery Chargers | 2.11.2 | |||||||||||||||
| 599 | 28 31 76 | 06 | Test Reports | Field Quality Control | 3.7 | |||||||||||||||
| 600 | 28 31 76 | 06 | Test Reports | Testing Procedures | 3.7.1 | G | ||||||||||||||
| 601 | 28 31 76 | 06 | Test Reports | Smoke Sensor Testing | 2.9.3 | G | ||||||||||||||
| 602 | 28 31 76 | 07 | Certificates | Installer | 1.8.1.4 | |||||||||||||||
| 603 | 28 31 76 | 07 | Certificates | Formal Inspection and Tests | 3.7.2.2 | G | ||||||||||||||
| 604 | 28 31 76 | 07 | Certificates | Preliminary Testing | 0 | G | ||||||||||||||
| 605 | 28 31 76 | 07 | Certificates | Final Testing | 3.7.2.3 | G | ||||||||||||||
| 606 | 28 31 76 | 09 | Manufacturer’s Field Reports | System Operation | 2.3 | G | ||||||||||||||
| 607 | 28 31 76 | 09 | Manufacturer’s Field Reports | Fire Alarm System | 1.8.2.2 | G | ||||||||||||||
| 608 | 28 31 76 | 10 | Operation and Maintenance Data | Operation and Maintenance (O&M) Instructions | 3.10 | G | ||||||||||||||
| 609 | 28 31 76 | 10 | Operation and Maintenance Data | Instruction of Government Employees | 3.8 | G | ||||||||||||||
| 610 | 28 31 76 | 11 | Closeout Submittals | As-Built Drawings | 3.7.2.4 | G | ||||||||||||||
| 611 | 31 00 00 | 03 | Product Data | Utilization of Excavated Materials | 3.7 | |||||||||||||||
| 612 | 31 00 00 | 03 | Product Data | Opening of any Excavation or Borrow Pit | 0 | |||||||||||||||
| 613 | 31 00 00 | 06 | Test Reports | Testing | 3.12 | G | ||||||||||||||
| 614 | 31 00 00 | 06 | Test Reports | Borrow Site Testing | 0 | G | ||||||||||||||
| 615 | 31 00 00 | 07 | Certificates | Testing | 3.12 | |||||||||||||||
| 616 | 32 12 16 | 03 | Product Data | Mix Design | 2.4 | G | ||||||||||||||
| 617 | 32 12 16 | 03 | Product Data | Quality Control | 3.8 | |||||||||||||||
| 618 | 32 12 16 | 03 | Product Data | Material Acceptance | 3.9 | G | ||||||||||||||
| 619 | 32 12 16 | 03 | Product Data | Percent Payment | 1.1.3 | |||||||||||||||
| 620 | 32 12 16 | 04 | Samples | Asphalt Cement Binder | 2.3 | |||||||||||||||
| 621 | 32 12 16 | 04 | Samples | Aggregates | 2.2 | |||||||||||||||
| 622 | 32 12 16 | 06 | Test Reports | Aggregates | 2.2 | G | ||||||||||||||
| 623 | 32 12 16 | 06 | Test Reports | QC Monitoring | 3.8.2.10 | |||||||||||||||
| 624 | 32 12 16 | 07 | Certificates | Asphalt Cement Binder | 2.3 | |||||||||||||||
| 625 | 32 12 16 | 07 | Certificates | Testing Laboratory | 0 | |||||||||||||||
| 626 | 32 16 19 | 03 | Product Data | Concrete | 2.1 | G | ||||||||||||||
| 627 | 32 16 19 | 06 | Test Reports | Field Quality Control | 3.8 | |||||||||||||||
| 628 | 32 17 23 | 03 | Product Data | Surface Preparation Equipment List | 2.1.1.1 | |||||||||||||||
| 629 | 32 17 23 | 03 | Product Data | Application Equipment List | 2.1.2 | |||||||||||||||
| 630 | 32 17 23 | 03 | Product Data | Exterior Surface Preparation | 3.2 | |||||||||||||||
| 631 | 32 17 23 | 03 | Product Data | Safety Data Sheets | 1.4.1 | |||||||||||||||
| 632 | 32 17 23 | 03 | Product Data | Waterborne Paint | 2.2.1 | G | ||||||||||||||
| 633 | 32 92 19 | 03 | Product Data | Wood Cellulose Fiber Mulch | 0 | |||||||||||||||
| 634 | 32 92 19 | 03 | Product Data | Fertilizer | 2.3 | |||||||||||||||
| 635 | 32 92 19 | 06 | Test Reports | Topsoil Composition Tests | 2.2.3 | |||||||||||||||
| 636 | 32 92 19 | 07 | Certificates | Seed | 2.1 | |||||||||||||||
| 637 | 33 05 29.00 29 | 03 | Product Data | Materials | 1.4.1 | G | ||||||||||||||
| 638 | 33 05 29.00 29 | 06 | Test Reports | Hydrostatic tests | 3.14 | G | ||||||||||||||
| 639 | 33 05 29.00 29 | 06 | Test Reports | Disinfection | 2.7 | G | ||||||||||||||
| 640 | 33 05 29.00 29 | 08 | Manufacturer’s Instructions | Manufacturer's Recommendations | 1.4.2 | |||||||||||||||
| 641 | 33 05 33.00 29 | 03 | Product Data | Materials | 1.4.1 | G | ||||||||||||||
| 642 | 33 05 33.00 29 | 06 | Test Reports | Hydrostatic tests | 1.4.2 | G | ||||||||||||||
| 643 | 33 05 33.00 29 | 08 | Manufacturer’s Instructions | Manufacturer's Recommendations | 1.4.3 | |||||||||||||||
| 644 | 33 05 37.00 29 | 01 | Preconstruction Submittals | Welder qualifications | 3.4 | |||||||||||||||
| 645 | 33 05 37.00 29 | 03 | Product Data | Valves | 2.3 | G | ||||||||||||||
| 646 | 33 05 37.00 29 | 03 | Product Data | Steam Traps | 2.4 | G | ||||||||||||||
| 647 | 33 05 37.00 29 | 03 | Product Data | Expansion Joints | 2.8 | G | ||||||||||||||
| 648 | 33 05 37.00 29 | 03 | Product Data | Pipe Alignment Guides | 2.8 | G | ||||||||||||||
| 649 | 33 05 37.00 29 | 03 | Product Data | Insulation | 3.6 | G | ||||||||||||||
| 650 | 33 05 37.00 29 | 06 | Test Reports | Tests | 3.7 | G |