JA-4_Drawings.pdf

PDF 4 MB Posted

Attached to
Low Bay Office Lighting FTQW 11-1502 Federal contract opportunity
Solicitation number
FA5004-17-B-C005
Issued by
Department of the Air Force Pacific Air Forces

About this file

JA-4 Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Low Bay Office Lighting FTQW 11-1502, newest first.
File Type Posted
Questions_and_Answers_Low_Bay.pdf PDF
JA-3_Additional_Construction_Documents.pdf PDF
FA5004-17-B-C005-0002.pdf PDF
JA-2_Specifications.pdf PDF
JA-4_Drawings.pdf PDF
FA5004-17-B-C005-0001.pdf PDF
JA-3_Additional_Construction_Documents.pdf PDF
JA-3_Additional_Construction_Documents.pdf PDF
JA-5_AF_Form_66.pdf PDF
JA-6_Wage_Determination.pdf PDF
JA-2_Specifications.pdf PDF
FA5004-17-B-C005.pdf PDF
JA-1_Other_Contract_Requirements.pdf PDF
JA-4_Drawings.pdf PDF
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

G

FA5004-17-B-C005-0001 EIELSON AFB, AK ATTACHMENT JA-4 DRAWINGS

NORTH ARROWS

ROOM NUMBER

SCALE

TITLE

SHEET LOCATION

DETAIL NUMBER

A A4

SHEET LOCATION

SECTION NUMBER

DETAIL NUMBER

OFFICE

SHEET LOCATION

A A4

G000 TITLE SHEET

G001 GENERAL INFORMATION

DWG

DRAWING TITLE

SCALE

GOVERNING CODES:

2012 INTERNATIONAL BUILDING CODE - IBC

2012 INTERNATIONAL FIRE CODE - IFC

2015 NFPA 101 LIFE SAFETY CODE

2014 NFPA 70 - NATIONAL ELECTRICAL CODE - NEC

AUTHORITY HAVING JURISDICTION

E001 N/A GENERAL LIGHTING SCHEDULES, CRITERIA AND DETAILS

E101 3110 BUILDING 3110 LIGHTING DEMO PLAN

E201 3110 BUILDING 3110 LIGHTING PLAN

E101 2268 BUILDING 2268 LIGHTING DEMO PLAN

E201 2268 BUILDING 2268 LIGHTING PLAN

E101 3343 BUILDING 3343 MAIN FLOOR LIGHTING DEMO PLAN AREA 1

E102 3343 BUILDING 3343 MAIN FLOOR LIGHTING DEMO PLAN AREA 2

E103 3343 BUILDING 3343 SECOND FLOOR LIGHTING DEMO PLANS

E201 3343 BUILDING 3343 MAIN FLOOR LIGHTING PLAN AREA 1

E202 3343 BUILDING 3343 MAIN FLOOR LIGHTING PLAN AREA 2

E203 3343 BUILDING 3343 SECOND FLOOR LIGHTING PLANS

E101 3303 BUILDING 3303 LIGHTING DEMO PLAN

E201 3303 BUILDING 3303 LIGHTING PLAN

E101 1216 BUILDING 1216 LIGHTING DEMO PLANS

E201 1216 BUILDING 1216 LIGHTING PLANS

E101 1127 BUILDING 1127 LIGHTING DEMO PLAN

E201 1127 BUILDING 1127 LIGHTING PLAN

G

E

ELECTRICAL SYMBOL LEGEND

NOTE KEY - INDICATES NOTES APPLICABLE ON EACH SHEET

A3 LIGHTING FIXTURE TYPE - SEE LIGHTING FIXTURE SCHEDULE

SWITCHES UP 4'-0", UON: SPST; THREE-WAY

PILOT LIGHT SWITCH: LIGHTED IN 'OFF' POSITION

OCCUPANCY SENSOR, CEILING OR WALL UP 7'-6" AFF, UON ('X'=TYPE)

SURFACE OR PENDANT MOUNTED FIXTURE -

SEE LIGHTING FIXTURE SCHEDULE

WALL MOUNTED FIXTURE - SEE LIGHTING FIXTURE SCHEDULE

RECESSED DOWNLIGHT FIXTURE - SEE LIGHTING FIXTURE SCHEDULE

RECESSED OR SURFACE CEILING MOUNTED FIXTURE - SEE LIGHTING

FIXTURE SCHEDULE

FILLED TRIANGLE PATTERN INSIDE DEPICTED FIXTURE, TO INCLUDE

EMERGENCY BALLAST INTEGRAL TO FIXTURE

WALL MOUNTED LINEAR FIXTURE - SEE LIGHTING FIXTURE SCHEDULE

NL INDICATES NIGHT LIGHT FIXTURE - NOT ON SWITCHED CIRCUIT

WALL MOUNTED EMERGENCY FIXTURE - SEE LIGHTING FIXTURE SCHEDULE

EMERGENCY EXIT LIGHTING UNIT WITH ARROWS WHERE SHOWN: CEILING

MOUNTED; WALL MOUNTED - SEE LIGHTING FIXTURE SCHEDULE

PANELBOARD: FLUSH MOUNTED, SURFACE MOUNTED

JUNCTION BOX

WP WEATHERPROOF

UON UNLESS OTHERWISE NOTED

LOW VOLTAGE CONTROL CABLE - OCCUPANCY SENSOR INTERCONNECTIONS

CONCEALED CONDUIT (NOTE A BELOW)

EXPOSED CONDUIT (NOTE A BELOW)

INDICATES HOME-RUN (NUMBER OF ARROWS = NUMBER OF CIRCUITS)

(NOTE B BELOW)

OSX

L

ALL BRANCH CIRCUITS 2#12, 1/2" C. TO 20A., 1P. CIRCUIT BREAKER U.O.N.

e.g. A-30(4 #8, 3/4" C. TO 40/3) INDICATES CIRCUIT BREAKER 30

IN PANEL 'A' FEEDS TO EQUIPMENT FROM A 40 A. 3P. CIRCUIT BREAKER WITH

4 #8 AWG WIRES RUN IN 3/4" CONDUIT.

A. NO. OF WIRES (IF OTHER THAN 2) INDICATED BY NO. OF SLASHES

( = TWO 'HOT' WIRES AND TWO NEUTRAL WIRES )

B. HOME-RUN DESIGNATION: 'A' = PANELBOARD NOTATION, '-2,4' = CIRCUIT

NUMBERS

C. INSTALL INSULATED GROUNDING CONDUCTOR, SIZED IN ACCORDANCE

WITH NEC REQUIREMENTS IN ALL FEEDER AND BRANCH CIRCUIT

CONDUITS.

SYMBOLS SHOWN ABOVE ARE DRAWN AS THEY ARE USED ON THE

DRAWINGS TO INDICATE NEW WORK OR NEW LOCATIONS OF EXISTING

EQUIPMENT. EXISTING EQUIPMENT TO BE ABANDONED IN PLACE, REMOVED

OR RELOCATED IS SHOWN USING THE SAME SYMBOLS BUT DRAWN WITH

DASHED LINES.

GENERAL PROJECT NOTES

1. THE PROJECT'S MAIN GOALS ARE TO REPLACE THE EXISTING INEFFICIENT FLUORESCENT (PREDOMINANTLY T12 TYPE) LIGHTING SYSTEMS WITH

NEW ENERGY EFFICIENT AND LONG LIFE LED LIGHTING THROUGHOUT MOST OCCUPIED AREAS OF THE BUILDINGS INCLUDED WITHIN THE

PROJECT.

2. FLUORESCENT BALLASTS WITHIN THE WORK WHICH WILL BE DEMOLISHED HAVE NOT BEEN IDENTIFIED AS TO WHETHER THEY CONTAIN PCB'S OR NOT. CONTRACTOR SHALL TAKE RESPONSIBILITY FOR REMOVAL, TESTING, AND APPROPRIATE DISPOSAL OF THESE BALLASTS REMOVED FROM THE BUILDING. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR SAFE DISPOSAL OF THE FLUORESCENT LAMPS REMOVED DURING THE DEMOLITION PHASE OF THE PROJECT AND PROVIDE DOCUMENTATION OF PROPER DISPOSAL OF FLUORESCENT LAMPS AND BALLASTS

CONTAINING PCP'S.

2.1. WITHIN THE DEMOLITION DRAWING SOME LIGHTS HAVE NUMBERS ASSOCIATED WITH THEM FROM THE AS-BUILT INFORMATION OR SITE INVESTIGATIONS. THESE NUMBERS ARE INTENDED TO PROVIDE AN ESTIMATED NUMBER OF LAMPS WITHIN THE GIVEN FIXTURE.

- FOR EXAMPLE A 'T2' LIGHT WOULD INDICATE THE LIGHT CONTAIN 2 (FLUORESCENT) LAMPS. THIS WILL ASSIST THE CONTRACTOR IN

DEVELOPING A COST FOR DISPOSAL OF THESE QUANTITY OF LAMPS.

3. EXISTING HOME RUN CIRCUITS TO THE LIGHTING SYSTEM MAY BE RE-UTILIZED AS THE NEW LIGHTING POWER USAGE WILL BE LOWER THAN EXISTING. THESE EXISTING HOME RUN CIRCUITS AND WIRING SHALL REMAIN MOSTLY AS-IS FOR THE WORK. WITHIN THE ROOMS ADDITIONAL WORK WILL BE INCLUDED TO ACCOMMODATE THE NEW LIGHTING AND/OR CONTROLS FOR THESE SYSTEMS.

4. THE CONTRACTOR SHALL PROVIDE NEW CIRCUIT CONDUCTORS AS NEEDED TO SUPPORT FINAL CONNECTIONS TO THE NEW LIGHTS; CONTROLS INCLUDING OCCUPANCY SENSORS AND SWITCHING. WHERE EXISTING CONDUITS ARE SUITABLE FOR ROUTING THE NEW CIRCUIT CONDUCTORS THEY MAY BE RE-USED. WHERE NEW BOXES OR CONNECTIONS REQUIRE NEW CONDUIT SYSTEMS, THE CONTRACTOR SHALL PROVIDE THESE

SYSTEMS TO PRODUCE A FULLY FUNCTIONAL LIGHTING AND/OR CONTROL SYSTEM.

5. CONDUCTORS UTILIZED FOR LOW VOLTAGE CONNECTIONS (FOR EXAMPLE USED IN OCCUPANCY SENSORS AND LOW VOLTAGE 0-10V DIMMING SYSTEMS) MAY UTILIZE PLENUM RATED CABLES FOR THESE INTER-CONNECTIONS AND ARE NOT SPECIFICALLY REQUIRED TO BE ROUTED IN

RACEWAY SYSTEMS. CABLES SHALL HOWEVER BE SUPPORTED PER NEC REQUIREMENTS.

6. LIGHTING FIXTURE WHIPS WHICH PROVIDE BOTH POWER AND LOW VOLTAGE CONTROL FUNCTIONS MAY UTILIZE MC CABLES SPECIFICALLY INTENDED FOR THIS PURPOSE. CONTRACTOR SHALL PROVIDE APPROPRIATE SEPARATION OF THESE SYSTEMS IN THE ASSOCIATED JUNCTION

BOXES AS APPLICABLE TO NEC ARTICLES.

7. CIRCUITS AND PANEL SCHEDULES ASSOCIATED WITH THE LIGHTING WORK SHALL BE TRACED AND VERIFIED PRIOR TO WORK. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL PROVIDE NEW TYPEWRITTEN CIRCUIT IDENTIFICATIONS WITHIN NEW PANELS

SCHEDULES FOR ALL AFFECTED CIRCUITS.

8. FACILITIES INCLUDED WITHIN THIS WORK SHALL REMAIN IN OPERATION THROUGHOUT THE CONSTRUCTION PROCESS AND CONTRACTOR SHALL COORDINATE THE WORK IN SUCH A WAY AS TO MINIMIZE IMPACTS TO NORMAL OPERATIONS FOR THE FACILITIES. THIS COORDINATION MAY INCLUDE AFTER HOURS OR WEEKEND WORK TO ACCOMMODATE THE REPLACEMENT OF THE LIGHTING SYSTEMS. CONTRACTOR SHALL ENSURE THE PROJECT AREAS ARE CLEANED UP AND OPERATIONAL FOR BUILDING USERS AS REQUIRED TO MINIMIZE THESE IMPACTS.

9. NEW EXTERIOR LIGHTS SHOWN ON DRAWINGS ARE TO REPLACE EXISTING LIGHTS WHERE INSTALLED. WHERE NO EXISTING LIGHTS EXIST NO ADDITIONAL WORK WILL BE INDICATED FOR THE BUILDING WITH EXCEPTION OF ADDITIONAL EXTERIOR EMERGENCY EGRESS LIGHTING WHICH IS

REQUIRED BY CODE.

10. ROOM NUMBERS NOTED ON DRAWINGS WERE ASSIGNED USING AVAILABLE AS-BUILT INFORMATION AND OTHER SOURCES, BUT MAY NOT MATCH SPECIFICALLY THE NUMBERING CONVENTION WITHIN THE ACTUAL FACILITY. THESE NUMBERS WERE USED TO COORDINATE LIGHTING CALCULATIONS WITH THE ROOMS IN THE DESIGN EFFORT. THE CONTRACTOR SHALL COORDINATE WITH EACH FACILITY ON THE SPECIFIC NUMBERING OR LETTERING CONVENTION AND ROOM NAME ALLOCATIONS FOR THE SPACES AFFECTED BY THE CONSTRUCTION EFFORT AND AS

BUILT THESE IDENTIFICATIONS ON THE REDLINED DRAWINGS.

11. THE NUMERICAL DESIGNATION IN THE LIGHT FIXTURES THROUGHOUT ARE IS INTENDED TO DEPICT THE APPROXIMATE NUMBER OF T12 OR T8 LAMPS WHICH WILL NEED TO BE DISPOSED OF AS PART OF THE WORK; I.E F2 = 2-LAMPS, F3= 3 LAMPS, ECT... T5 TYPE LAMPS ARE IDENTIFIED WITH AN 'H' PREFIX. LIGHTS WITHOUT ANY ID ARE EITHER HID OR INCANDESCENT LAMPS WITH NO SPECIAL DISPOSAL REQUIREMENTS

12. PROVIDE ARCHITECTURAL DEMOLITION REQUIRED TO ACCOMMODATE NEW WORK.

13. WHERE FINISHES CALL TO 'MATCH EXISTING': MATERIAL, FINISH AND COLOR TO MATCH EXISTING ADJACENT MATERIAL, FINISH AND COLOR TO

THE GREATEST EXTENT POSSIBLE.

14. WHERE LIGHTING FIXTURES ARE DEMOLISHED AT ACOUSTIC CEILING TILE GRIDS TO REMAIN: PROVIDE PROVIDE INFILL ACOUSTIC TILE AT

REMOVED FIXTURE LOCATION; CEILING TILE TO MATCH EXISTING.

15. WHERE LIGHTING FIXTURES ARE DEMOLISHED AT HARD LIDS AND NEW FIXTURES DON'T COVER THE EXISTING PENETRATIONS OR DEMOLISHED LIGHT FIXTURE FOOTPRINT COMPLETELY: PATCH, REPAIR, AND REFINISH SURFACES TO MATCH EXISTING.

15.1. IF 50% OF FIXTURE PENETRATIONS AT ROOM ARE BEING PATCHED, PAINT ENTIRE CEILING AREA OF ROOM.

15.2. IF MORE THAN 50% OF FIXTURE PENETRATIONS REQUIRE NO WORK, BLEND PAINTED AREA OF PATCHED LOCATIONS TO MATCH EXISTING, APPROXIMATELY 4SF PER LOCATION.

16. WHERE WALL MOUNTED LIGHT FIXTURES ARE DEMOLISHED: PATCH, REPAIR, AND PAINT WALL TO MATCH EXISTING.

16.1. IF THREE OR MORE FIXTURE PATCHES OCCUR ON ONE WALL, PAINT ENTIRE AREA OF WALL TO MATCH EXISTING.

16.2. IF LESS THAN THREE FIXTURE PATCHES ARE REQUIRED ON ONE WALL, BLEND PAINTED AREA OF PATCHED LOCATION TO MATCH EXISTING, APPROXIMATELY 4SF PER LOCATION.

17. WHERE PENDANT LIGHTS ARE REMOVED AND/OR REPLACED, NEW CEILING FINISHES ARE NOT REQUIRED.

LIGHTING FIXTURE SCHEDULE

TYPE NOMINAL

POWER

LUMEN

CCT

DESCRIPTION MOUNTING

HEIGHT

BASIS OF DESIGN

A1 20W 2,380 4000K

2'X4' RECESSED LAY-IN FLAT PANEL LED

TROFFER WITH EVENLY DISPERSED LOW

GLARE ILLUMINATION OVER THE FACE OF

THE LIGHT, 120-277V DIMMABLE.

RECESSED

CEILING

DECO

SFP-LED-24-20-40-UNV

(PROVIDE EM FOR EMERGENCY

BACKUP OR SMK IF SURFACE MTD)

A2 31W 3,700 4000K

SAME AS A1 WITH HIGHER LUMEN OUTPUT. RECESSED

CEILING

DECO

SFP-LED-24-30-40-UNV

A3 41W 4,800 4000K

SAME AS A1 WITH HIGHER LUMEN OUTPUT. RECESSED

CEILING

DECO

SFP-LED-24-40-40-UNV

B1 20W 2,380 4000K

1'X4' SURFACE MOUNT FLAT PANEL LED

TROFFER WITH EVENLY DISPERSED LOW

GLARE ILLUMINATION OVER THE FACE OF

THE LIGHT, 120-277V DIMMABLE.

RECESSED

CEILING

DECO

SFP-LED-14-20-40-UNV-SMK

(PROVIDE EM FOR EMERGENCY

BACKUP OR SMK IF SURFACE MTD)

B2 31W 3,700 4000K

SAME AS B1 WITH HIGHER LUMEN OUTPUT. RECESSED

CEILING

DECO

SFP-LED-14-30-40-UNV-SMK

B3 41W 4,800 4000K

SAME AS B1 WITH HIGHER LUMEN OUTPUT. RECESSED

CEILING

DECO

SFP-LED-14-40-40-UNV-SMK

C1 20W 2,130 4000K

2'X2' RECESSED LAY-IN FLAT PANEL LED

TROFFER WITH EVENLY DISPERSED LOW

GLARE ILLUMINATION OVER THE FACE OF

THE LIGHT, 120-277V DIMMABLE.

RECESSED

CEILING

DECO

SFP-LED-22-20-40-UNV

(PROVIDE EM FOR EMERGENCY

BACKUP OR SMK IF SURFACE MTD)

C2 30W 3,160 4000K

SAME AS C1 WITH HIGHER LUMEN OUTPUT. RECESSED

CEILING

DECO

SFP-LED-22-30-40-UNV SMK

C3 40W 4,760 4000K

SAME AS C1 WITH HIGHER LUMEN OUTPUT. RECESSED

CEILING

DECO

SFP-LED-22-40-40-UNV SMK

D1 65W 8,100 4000K

ECONOMY 2' HIGH/LOW BAY LED LIGHT

FIXTURE, AREAS WITH MOUNTING HEIGHTS

FROM 10 TO 40 FT, MULTI-VOLT DRIVER.

FROSTED LENS FOR EVEN DISTRIBUTION.

PENDANT DECO

DHL-LP-LED-2-65-40-UNV-F

(PROVIDE EM OPTION AS SHOWN)

D2 90W 11,600 4000K

SAME AS D1 WITH HIGHER LUMEN OUTPUT. PENDANT DECO

DHL-LP-LED-2-90-40-UNV-F

D3 135W 17,050 4000K

SAME AS D1 WITH HIGHER LUMEN OUTPUT. PENDANT DECO

DHL-LP-LED-2-135-40-UNV-F

ER 10.85W

6 VDC

INPUT

COLD WEATHER RATED, ARCHITECTURAL

EMERGENCY LIGHTING REMOTE FIXTURE.

POWERED VIA FIXTURE TYPE 'EX'.

WALL LITHONIA LIGHTING

ELA-AFNR-DB-FWD

ET 5W

6-12 VDC

INPUT

INTERIOR TWIN HEAD ARCHITECTURAL

EMERGENCY LIGHTING REMOTE FIXTURE.

POWERED VIA FIXTURE TYPE 'EX'.

WALL LITHONIA LIGHTING

ELA W T L24 LP03VS

EX 3.3W 17,500

4000K

LED EXIT SIGN WITH WHITE

THERMOPLASTIC HOUSING, GREEN/RED

LETTERING, AND A HIGH-OUTPUT 6V/12W

LEAD-ACID BATTERY. POWERS FIXTURE

TYPE 'ER'.

WALL LITHONIA LIGHTING

LHQM-S-W-3-(G/R)-HO RO

(MATCH LETTERING COLOR FOR

REMAINDER OF EXIT LIGHTS FOR

EACH SPECIFIC FACILITY)

G1 60W 6,700 4000K

4' INDUSTRIAL VAPORTIGHT LED WITH

METAL HOUSING INSIDE A FIBERGLASS

SHELL, MULTI-VOLT DRIVER.

SURFACE

OR

PENDANT

DECO

DWH-LED-6-60-40-UNV

G2 100W 10,875 4000K

4' ENCLOSED VAPOR TIGHT LED WITH

METAL HOUSING INSIDE A FIBERGLASS

SHELL, POLYCARBONATE LENS AND

INTEGRATED MOTION SENSOR,

MULTI-VOLT DRIVER.

SURFACE

OR

PENDANT

DECO

DWP-LED-100-40-UNV-PC-MS

H1 25W 2,560 4000K

4' ROUND SURFACE MOUNT WITH DIE

FORMED CHANNEL AND FROSTED DIFFUSE

LENS, MULTI-VOLT DRIVER.

SURFACE DECO

DACH-LED-4-25-40-UNV-R

H2 35W 3,710 4000K

SAME AS H1 EXCEPT 4' LONG AND WITH

HIGHER OUTPUT.

SURFACE DECO

DACH-LED-4-35-40-UNV-R

H3 45W 5,415 4000K

SAME AS H1 EXCEPT 4' LONG AND WITH

HIGHER OUTPUT.

SURFACE DECO

DACH-LED-4-50-40-UNV-R

J1 35W 3,325 4000K

4' LINEAR SUSPENDED DIRECT LED

LUMINAIRE ACRYLIC DIFFUSER AND

ALUMINUM BODY, MULTI-VOLT DRIVER.

PENDANT DECO

BEAM-LED-4-35-()-40-UNV

J2 45W 4,275 4000K

SAME AS J1 WITH HIGHER LUMEN OUTPUT PENDANT DECO

BEAM-LED-4-45-()-40-UNV

M1 18W 1,500 4000K

6" LED RETROFIT CAN LIGHT FOR

INSTALLATION IN EXISTING HOUSING,

120-277V

RECESSED DECO

DLED-E-RET-6-18-40-UNV

N1 137W 25,100 4000K

LOW PROFILE HIGH BAY FIXTURE WITH

POLYCARBONATE LENS AND ALUMINUM

HEAT SINKS. MULTI-VOLT DRIVER.

PENDANT

+35' GYM

+16' POOL

LUMAX

HBRLED251L4K24-9CP

N2 460W 59,000 4000K

SIMILAR TO N1, BUT DIFFERENT LUMEN

OUTPUT.

PENDANT

+35' AFF

LUMAX

HBRLED629L4K48-9CP

N3 69W 9,400 4000K

SIMILAR TO N1, BUT DIFFERENT LUMEN

OUTPUT.

PENDANT

+35' GYM

LUMAX

HBRLED94L4K24-9CP

NE 137W 25,100

4000K

SAME AS N1, BUT ONLY USED FOR

EMERGENCY OPERATIONS

PENDANT

+35' GYM

LUMAX

HBRLED251L4K24-9CP

R1 15W 1,077 4000K

OUTDOOR GENERAL PURPOSE ROUND

CAST LED FLUSH MOUNT FIXTURE, 120V

SURFACE LITHONIA

OLCFM 15 WH

S1 30W 3,045 4000K

MEDIUM WALL PACK LED LIGHT WITH

ALUMINUM BODY, MOUNTED ABOVE DOOR,

120-277V WITH PHOTOCELL OPTION.

SURFACE DECO DECO-LED-30-40-UNV-BZ-PC

T1 94W 9,500 4000K

2X4 RECESSED FIXTURE FOR

RACQUETBALL COURT INSTALLATION,

TEMPERED GLASS LENS AND HEAVY DUTY

ALUMINUM HOUSING, MULTI-VOLT DRIVER.

RECESSED

CEILING

1ST SOURCE LIGHTING

RSD RCFM24 494 40 OTG U

(PROVIDE EM OPTION WHERE

SHOWN ON DRAWINGS)

U1 15W 1,240 4000K

SURFACE MOUNT RETROFIT KIT FOR

MOUNTING TO JUNCTION BOXES AND

INCLUDES TRIM RING, 120V.

SURFACE

CEILING

DECO

DLED-FRET-6-15-40-120-WH-RM

V1 30W 3,050 4000K

VANDAL RESISTANT CANOPY LIGHT WITH

SYMMETRICAL DISTRIBUTION AND MULTI

LEVEL MOTION SENSING CONTROL,

MUTLT-VOLT DRIVER.

SURFACE

CEILING

DECO

D536-LED-30-40-UNV-BL-BI-MSL2

W1 30W 3,040 4000K

QUARTER SPHERE WALL LIGHT WITH TYPE

IV DISTRIBUTION PHOTOCELL, MULTI-VOLT

DRIVER AND EM BACKUP.

SURFACE

WALL

DECO

D441-LED-30-40-UNV-BL-T4-BL-PC-EM

X1 29W 3,000 4000K

HALF-ROUND VERTICAL WALL SCONCE

WITH LED ELEMENTS AND MULTI-VOLT

DRIVER, GRAPHITE METALLIC COLOR.

SURFACE

WALL

SHAPER

673-37-W-L840-UNV-GRM

INV-250 & INV-400 EMERGENCY LIGHTING INVERTER UNITS:

INVERTERS FOR EMERGENCY LIGHTS BASIS OF DESIGN ARE PHILLIPS BODINE ELI-S-250 AND ELI-S-400 UNITS.

EMERGENCY LIGHTING REMOTE HEAD UNIT

SWITCH CONTROL FOR EXTERIOR LIGHTSEXT

Donald L. Hopkins

No. EE10582

ITEMS TYPICALLY SHOWN ON DEMOLITION

DRAWINGS WITH LIGHT DASHED LINES ARE TO BE

DEMOLISHED AS PART OF THE WORK UNLESS

SPECIFICALLY NOTED ON DRAWING FOR REUSE (R)

EXISTING TO REMAIN(E)

CABLE VAULT AREA

WITH WALL MOUNT

INCANDESCENT GLOBES

AND METAL PROTECTIVE

COVERS TO REMAIN

STORAGE/

ELECTRIC

MECH RM

BACKUP

POWER

OFFICE

112 ROOM

ROOM

VESTIBULE

V2

HALLWAY

H1

HALL

H2

VESTIBULE

V1

RESTROOM

JANITOR

RESTROOM

STORAGE

OFFICE

MECH

ROOM

VAULT

105ASTORAGE

SERVERS/

SWITCHES

106a

HALLWAY

H3

SERVERS/

SWITCHES

106c

CEILING GRID IN THIS AREA

TO BE DEMOLISHED

PANEL 'C'

PANEL 'M'

PANEL 'BATT ROOM'

PANEL 'GM'

PANEL 'MDP'

PANEL 'GMDP'

CT CAN & METER

SHUNT TRIP

PANEL 'D' &

DISCONNECT THROUGH WALL ABOVE

CEILING VENTS (TYP)

PANEL '??'

PANEL '??'

PANEL 'B'

SERVERS/

SWITCHES

106b

H4 FIXTURES IN THIS AREA USE T5HO LAMPS

E101

BUILDING 3110 LIGHTING DEMO PLAN

1/4"=1'-0"

E

GENERAL NOTES

1. THE EXISTING CEILING GRID AND ANY LAY-IN TILES IN ROOM 106b TO BE REMOVED BY THE CONTRACTOR AND DISPOSED OF. COORDINATE THIS

WORK TO HAVE THE MINIMAL IMPACTS TO THE NORMAL OPERATIONS OF THE FACILITY DURING THIS DEMOLITION EFFORT. EXISTING LIGHTING MAY REMAIN FOR USE AS TEMPORARY LIGHTING IF SUPPORTED BY OTHER MEANS THAN THE CEILING GRID DURING THIS EFFORT. CONTRACTOR TO ALSO TAKE CARE TO MINIMIZE THE DEBRIS WHICH MAY HAVE COLLECTED ON THESE TILES FROM ENTERING THE SENSITIVE ELECTRONIC EQUIPMENT BELOW OR IMPACTING THE COMMUNICATIONS CABLES IN THE AREA. CONTRACTOR SHALL PROVIDE DROP CLOTHS OR OTHER PROTECTION NEEDED SO THE EQUIPMENT IS PROTECTED. NOTE NORMAL PLASTIC SHEETS MAY INTRODUCE STATIC WHEN DEPLOYED OR REMOVED SO THIS NEEDS TO BE

TAKEN INTO ACCOUNT WHEN THE PROTECTION IS SELECTED.

2. MECHANICAL DUCTS AND DIFFUSERS WHICH ARE CURRENTLY LOCATED WITHIN THE CEILING GRID TO BE INDEPENDENTLY SUPPORTED AND REMAIN

IN PLACE IN THE EXISTING LOCATIONS.

3. THE NUMERICAL DESIGNATION IN THE LIGHT FIXTURE IS INTENDED TO DEPICT THE APPROXIMATE NUMBER OF T12 LAMPS WHICH WILL NEED TO BE DISPOSED OF AS PART OF THE WORK; I.E F2 = 2-LAMPS, F3= 3 LAMPS, ECT... T5 TYPE LAMPS ARE IDENTIFIED WITH AN 'H' PREFIX. LIGHTS WITHOUT ANY ID ARE EITHER HID OR INCANDESCENT LAMPS WITH NO SPECIAL DISPOSAL REQUIREMENTS.

Donald L. Hopkins

No. EE10582

A2

A2

A1 A1

A1 A1

A1

A1

A1

A1

A1 A1 A1 A1 A1 A2

A1 A1

A2

A2

B1

H3

H1

A1

(E)

(E)

(E)

(E)

(E)

EX

EX

EX

EX

D1

D1

D1

D1

R1

S1ER

ER

ER

S1

PANEL 'C'

PANEL 'M'

PANEL 'BATT ROOM'

PANEL 'GM'

PANEL 'MDP'

PANEL 'GMDP'

CT CAN & METER

SHUNT TRIP

PANEL '??'

PANEL 'D' &

DISCONNECT

THROUGH WALL ABOVE

CEILING VENTS (TYP)

PANEL '??'

PANEL 'B'

STORAGE/

ELECTRIC

MECH RM

BACKUP

POWER

OFFICE

112 ROOM

ROOM

VESTIBULE

V2

HALLWAY

H1

HALL

H2

VESTIBULE

V1

RESTROOM

JANITOR

RESTROOM

STORAGE

OFFICE

MECH

ROOM

VAULT

105ASTORAGE

SERVERS/

SWITCHES

106a

HALLWAY

H3

SERVERS/

SWITCHES

106c

SERVERS/

SWITCHES

106b

(E)

(E)

E201

BUILDING 3110 LIGHTNG PLAN

1/4"=1'-0"

E

GENERAL NOTES

1. LIGHTING WITHIN THE SERVERS/SWITCHES AREAS CONTAINS A NUMBER OF DUCTS, CABLE TRAYS, EQUIPMENT RACKS AND OTHER EQUIPMENT

WHICH HAVE THE POTENTIAL TO IMPACT THE LOCATION OF THE NEW LIGHTING. THE CONTRACTOR SHALL COORDINATE WITH THE USERS AND ADJUST AS NEEDED THE FINAL LOCATION OF THE LIGHTS SHOWN IN THESE AREAS SO THEY PROVIDE THE OPTIMAL ILLUMINATION OF THE

EQUIPMENT WHICH REQUIRES IT.

2. THE EXISTING CEILING GRID AND ANY LAY-IN TILES IN ROOM 106b TO BE REMOVED BY THE CONTRACTOR AND DISPOSED OF. COORDINATE THIS WORK TO HAVE THE MINIMAL IMPACTS TO THE NORMAL OPERATIONS OF THE FACILITY DURING THIS DEMOLITION EFFORT. EXISTING LIGHTING MAY REMAIN FOR USE AS TEMPORARY LIGHTING IF SUPPORTED BY OTHER MEANS THAN THE CEILING GRID DURING THIS EFFORT. CONTRACTOR TO ALSO TAKE CARE TO MINIMIZE THE DEBRIS WHICH MAY HAVE COLLECTED ON THESE TILES FROM ENTERING THE ELECTRONIC EQUIPMENT BELOW. CONTRACTOR SHALL PROVIDE DROP CLOTHS OR OTHER PROTECTION NEEDED SO THE EQUIPMENT IS PROTECTED. NOTE NORMAL PLASTIC SHEETS MAY INTRODUCE STATIC WHEN DEPLOYED OR REMOVED SO THIS NEEDS TO BE TAKEN INTO ACCOUNT WHEN THE PROTECTION

IS SPECIFIED.

Donald L. Hopkins

HVAC

ENTRY

SERVER

ROOM

NET ADMIN

MECHANICAL

12bOFFICE

OFFICE

OFFICE

MECHANICAL

RESTROOM

106 ECO REPAIR

ROOM

CONFERENCE

OFFICE

OFFICE

OFFICE

ROOM

OFFICE

102ENTRY

RESTROOM

JANITOR

ALCOVE

HELP DESK

MECHANICAL

12a

E101

BUILDING 2268 LIGHTING DEMO PLAN

3/16"=1'-0"

E

GENERAL NOTES

1. THE LIGHT FIXTURES WITHIN THE FACILITY WHICH ARE IDENTIFIED WITH A 'F2' DESIGNATION ARE MEANT TO DESCRIBE THE APPROXIMATE

NUMBER OF T12 LAMPS PRESENT IN THE FIXTURE WHICH WILL NEED TO BE DISPOSED OF IN THE PROJECT. LIGHTS WITHOUT ANY ID ARE

EITHER HID OR INCANDESCENT LAMPS WITH NO SPECIAL DISPOSAL REQUIREMENTS.

Donald L. Hopkins

HVAC

ENTRY

SERVER

ROOM

NET ADMIN

MECHANICAL

12b

OFFICE

OFFICE

OFFICE

MECHANICAL

RESTROOM

ECO REPAIR

ROOM

CONFERENCE

OFFICE

OFFICE

OFFICE

ROOM

OFFICE

ENTRY

RESTROOM

JANITOR

ALCOVE

HELP DESK

MECHANICAL

12a

E201

BUILDING 2268 LIGHTING PLAN

3/16"=1'-0"

E

Donald L. Hopkins

B-13

OPEN OFFICE

B-11

VAULT

LOBBY

B-8

STORAGE

B-5

AB ROOM

ELECTRICAL

ROOM

B-3

STORAGE

B-2

STORAGE

B-1

LOBBY

B-15

CARDIO

GYMNASIUM

B-7

MASSAGE

B-10

STORAGE

B-13b

SECURE

OFFICE

STORAGE

STORAGE

STORAGE

RACQUETBALL 3RACQUETBALL 4

HALL

HALL HALL

B-12

ENTRY

STAIR

STAIR

STAIR

STAIR

E N

TR

Y

E N

TR

Y

B-13c

CASH CAGE

(E)

(E)

(E)

(E)

(E)

(E)

PANEL 'A2'

A2-2,4,6(E) A2-1,3,5

PANEL 'C'

PANEL 'E1'

PANELS 'J' & 'L'

'L' CONTROLLED BY

LIGHTING CONTACTOR

PANEL 'B'

PANEL 'A'

(E)

(E)

E101

BUILDING 3343 GYMNASIUM TO LOBBY FIRST FLOOR DEMO LIGHTING PLAN AREA 1

3/32"=1'-0"

E

GENERAL NOTES

1. THE NUMERICAL DESIGNATION IN THE LIGHT FIXTURE IS INTENDED TO DEPICT THE APPROXIMATE NUMBER OF T12 LAMPS WHICH WILL NEED TO BE DISPOSED OF AS PART OF THE WORK; I.E F2 = 2-LAMPS, F3= 3 LAMPS, ECT... LIGHTS WITHOUT ANY ID ARE EITHER HID OR INCANDESCENT LAMPS WITH NO SPECIAL DISPOSAL

REQUIREMENTS.

Donald L. Hopkins

C-1/3

DUMBBELL

ROOM

HOT TUB

SHOWERS

SAUNA

STEAM ROOM

SWIMMING POOL

REST RM

STEAM ROOM

STORAGE

SHOWERS

SAUNA

B-19

AEROBICS

C-11

FREE WEIGHT ROOM

DV

DRESSING ROOM

B-20

OFFICE

H A

LL

LAUNDRY

LOCKER

ROOM

REST RM

B-24

REST RM

REST RM

REST RM

REST RM

REST RM

REST RM

JC

S H

O W

ER

S H

O W

ER

B-23

STORAGE

FRONT DESK

ENTRY

HALL

HALL

L

HALL

HALL

HALL

HALL

HALL

HALL

H A

LL

C-10

STORAGE

LOCKER

ROOM

LOCKER

ROOM

LOCKER

ROOM

LOCKER

ROOM

STAIR

STAIR

STAIR

B-26

OFFICE

POOL DECK

UNDER POOL AREA

F2F2

F2F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2F2F2F2

F2F2F2F2

F2F2

F2

F2

F2

F2

F2

F2

F2

F2

F2 F2 F2 F2 F2

F2 F2 F2

F2

F2 F2

F2

F2

F2

F2

F2

F2 F2

F2

F2F2

PANEL 'D' PANEL 'G'

PANEL 'H'

PANEL 'DA'

PANEL 'HA'

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2 b b b b ba a a a a a

F2

F2 a

LIGHTS ON BOTTOM OF

SOFFIT FOR DUCTS

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2 F2 F2

F2 F2 F2

F2 F2 F2

F2 F2 F2

NL

NL

NL

NL

NL

AREA

ENTERS

MENS

LOCKER

ROOM

AREA

ENTERS

MENS

LOCKER

ROOM

SOFFITSOFFIT

PENDANT LIGHTS FOR POOL AREA

ARE CORD/PLUG CONNECTED (TYP)

(E)

(E)

(E)

(E) (E) (E)

(E)

SWIMMING POOL AREA LIGHTING

CONTROLLED VIA LIGHTING

CONTACTORS AND SWITCHES

E102

BUILDING 3343 LOBBY TO POOL FIRST FLOOR DEMO LIGHTING PLAN AREA 2

3/32"=1'-0"

E

GENERAL NOTES

1. THE NUMERICAL DESIGNATION IN THE LIGHT FIXTURE IS INTENDED TO DEPICT THE APPROXIMATE NUMBER OF T12 LAMPS WHICH WILL NEED TO BE DISPOSED OF AS PART OF THE WORK; I.E F2 = 2-LAMPS, F3= 3 LAMPS, ECT... LIGHTS WITHOUT ANY ID ARE EITHER HID OR

INCANDESCENT LAMPS WITH NO SPECIAL DISPOSAL REQUIREMENTS.

Donald L. Hopkins

LIGHT SWITCHES AND INDICATOR LIGHTS FOR

EMERGENCY BALLASTS AND TEST SWITCH

RB2

STORAGE

RB1

STORAGE

STORAGE ROOMS AT COURT LEVEL

VIEWING ROOM AT UPPER LEVEL

RB2

VIEWING

RB1

VIEWING

HALL

IR

MECHANICAL

POOL SEATING

RB2

ENTRY

RB1

ENTRY

RACQUETBALL 1RACQUETBALL2

PANEL 'J'

J-1,3,5 J-2,4,6

VIEWING ROOM AT UPPER LEVEL

PANEL 'G'

THIS AREA ILLUMINATED BY POOL SEATING LIGHTS

BREAK ROOM

STORAGE

UNDER

GYM

SEATING

NL

NL

NL

E103

BUILDING 3343 SECOND FLOOR GYM AREA S DEMO PLAN

3/32"=1'-0"

E

E103

BUILDING 3343 SECOND FLOOR POOL AREA N DEMO PLAN

3/32"=1'-0"

GENERAL NOTES

1. THE NUMERICAL DESIGNATION IN THE LIGHT FIXTURE IS INTENDED TO DEPICT THE APPROXIMATE NUMBER OF T12 LAMPS WHICH WILL NEED TO BE DISPOSED OF AS PART OF THE WORK;

I.E F2 = 2-LAMPS, F3= 3 LAMPS, ETC... LIGHTS WITHOUT ANY ID ARE EITHER HID OR INCANDESCENT LAMPS WITH NO SPECIAL DISPOSAL REQUIREMENTS.

SPECIFIC NOTES

Donald L. Hopkins

N2

N2

N2

N2

N2

N2

N2

N2 N2

N2

N2

N2

N2

N2

N2 N2

N2

N2

N2

N2 N2

N2

N2

N2

N2 N2

N2 N2

N2

N2

N2

N2

N2

N2

N2

N2

N2

N2

N2

A3

A3 A3

A3 A3

B1

B1

B1 B1

C2

A2

A2

U1

U1

U1 U1

A2

A2

A2

A2

A2

A2

A2

A2

A2 A2 A2

A2A2

B1

B-13

OPEN OFFICE

B-11

VAULT

LOBBY

B-8

STORAGE

B-5

AB ROOM

ELECTRICAL

ROOM

B-3

STORAGE

B-2

STORAGE

B-1

LOBBY

B-15

CARDIO

GYMNASIUM

B-7

MASSAGE

B-10

STORAGE

B-13b

SECURE

OFFICE

STORAGE

STORAGE

STORAGE

HALL

HALL HALL

B-12

ENTRY

STAIR

STAIR

STAIR

STAIR

E N

TR

Y

E N

TR

Y

B-13c

CASH CAGE

(E)

(E)

(E)

(E)

(E)

T1

T1

T1

T1

T1

T1

T1

T1

RACQUETBALL 3RACQUETBALL 4

(E)

PANEL 'A2'

A2-2,4,6 (E)

A2-1,3,5

T1 c

T1

T1 b

T1

T1 b

T1

T1 a

T1

N2

N2

N2 N2 N2

N1

PANEL 'C'

PANEL 'E1'

A3

A3

A3 A3 A3 A3 A3

A3A3A3A3A3

A3 A3 A3 A3 A3

U1 U1

1 1

V1

V1

V1

V1

V1

C1

C1

V1

W1

N1

N1

PANELS 'J' & 'L'

'L' CONTROLLED BY

LIGHTING CONTACTOR

PANEL 'B'

400W INVERTER

V1

V1

EX

EX

EX

EX

c b b aa b b c a b b c a a a a b b b b

(E)

E201

BUILDING 3343 GYMNASIUM TO LOBBY FIRST FLOOR LIGHTING PLAN AREA 1

3/32"=1'-0"

E

SPECIFIC NOTES

REPLACE PANELS IN COURT CEILING (8 PANELS) WHERE LIGHTING IS NOT RE-INSTALLED TO FILL HOLES FROM DEMOLITION OF FIXTURES. PANELS TO

MATCH ADJACENT PANELS.

N1 TYPE LIGHTING IN GYM AREA TO BE CONNECTED TO EMERGENCY POWER INVERTER TO PROVIDE REQUIRED ILLUMINATION DURING POWER OUTAGES.

THESE LIGHTS PROVIDE REQUIRED ILLUMINATION COVERAGE FOR THE GYMNASIUM AREA INCLUDING THE UPPER SEATING AREAS.

Donald L. Hopkins

A1 A1

N1 N1 N1

N1

N1 N1 N1

N1

C1

HOT TUB

SHOWERS

SAUNA

STEAM ROOM

SWIMMING POOL

REST RM

STEAM ROOM

STORAGE

SHOWERS

SAUNA

C-11

FREE WEIGHT ROOM

DV

DRESSING ROOM

B-20

OFFICE

H A

LL

STORAGE

LOCKER

ROOM

REST RM

REST RM

REST RM

REST RM

REST RM

REST RM

JC

S H

O W

ER

S H

O W

ER

FRONT DESK

ENTRY

HALL

HALL

L HALL HALL

HALL

HALL

HALL

HALL

H A

LL

C-10

STORAGE

LOCKER

ROOM

LOCKER

ROOM

LOCKER

ROOM

LOCKER

ROOM

STAIR

STAIR

STAIR

B-26

OFFICE

POOL DECK

UNDER POOL AREA

G2G2

G2

G1

G2

G2

G1

PANEL 'D'

PANEL 'H'

PANEL 'DA'

PANEL 'HA'

G2

G1

G2 G2G1

G2

G1

G1 G2 G1 G1

NL

NL

NL

NL

A3

A3

A3 A3

A3

A3

A3

A3

A3

A3

A3

A3

A3 A3

A3

A3

A1 A1 A1

A1A1A1

U1

A1 A1

A1 A1

A1

A1 A1

A1

A1 A1

NL NL

NL

A1 A1

A1 A1

A1 A1

A1 A1 A1

A1 A1

A1 A1 A1

A1 A1 A1 A1 A1 A1

LIGHTS ON BOTTOM OF

SOFFIT FOR DUCTS

SOFFITSOFFIT

C-1/3

DUMBBELL

ROOM

B-19

AEROBICS

U1

(E)

(E)

X1 X1

X1

X1

EX

EXEX

EX

EX

EX

AREA

ENTERS

MENS

LOCKER

ROOM

(E) (E)

U1

SWIMMING POOL AREA LIGHTING TO

BE RE-CONNECTED TO EXISTING

CONTROLS VIA LIGHTING

CONTACTORS AND SWITCHES

G2 TYPE LIGHTS HAVE INTEGRAL OCCUPANCY

SENSORS SO DO NOT NEED ADDITIONAL CONTROLS

SWITCH TO REMAIN TO CONTROL NIGHT LIGHT

FIXTURES SO THEY MAY BE TURNED OFF IF DESIRED,

BUT THIS WILL NOT INTERFERE WITH EMERGENCY

CIRCUIT WHICH SHALL BE UNSWITCHED

E202

BUILDING 3343 LOBBY TO POOL FIRST FLOOR LIGHTING PLAN AREA 2

3/32"=1'-0"

E

Donald L. Hopkins

STORAGE ROOMS AT COURT LEVEL

CONNECT TO EXISTING SWITCH

H1

H1

H1 H1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

C1 C1

HALL

IR

MECHANICAL

POOL SEATING

RB1

ENTRY

RB2

ENTRY

RB1

VIEWING

RB2

VIEWING

RB1

STORAGE

RB2

STORAGE

PANEL 'G'

A1

A1 A1

A1

VIEWING ROOM AT UPPER LEVEL

PANEL 'J'

VIEWING ROOM AT UPPER LEVEL

CENTER ROOM AT UPPER LEVEL

X1X1

N1N1N1

250W INVERTER

a b b c a b b cc b b a c b b a

RACQUETBALL 2RACQUETBALL 1

A1

A1 A1

A1 A1

A1

A1

A1 A1

A1A1

A1

J2

J2

J2

J2

J2

J2

J2

J2

J2

STORAGE

UNDER

GYM

SEATING

(E)

(E)

NL

N1

N1

N1

N1

N1

EX

EX

EX

EX

BREAKROOM

E203

BUILDING 3343 SECOND FLOOR GYM AREA S LIGHTING PLAN

3/32"=1'-0"

E

E203

BUILDING 3343 SECOND FLOOR POOL AREA N LIGHTING PLAN

3/32"=1'-0"

Donald L. Hopkins

PANEL 'L4'

PANEL 'L2'

PANEL 'L3'

MAIN DISCONNECT

& 3-PANELS

E101

BUILDING 3303 LIGHTING DEMO PLAN

1/4"=1'-0"

E

GENERAL NOTES

1. THE NUMERICAL DESIGNATION IN THE LIGHT FIXTURE IS INTENDED TO DEPICT THE APPROXIMATE NUMBER OF T12 LAMPS WHICH

WILL NEED TO BE DISPOSED OF AS PART OF THE WORK; I.E F = 2-LAMPS, F = 4 LAMPS.

2. ROOMS WHICH HAVE BANKS OF 3-WAY LIGHT SWITCHES NEAR THE ENTRY DOORS TO CONTROL VARIOUS LIGHTS WITHIN THE SPACE AS IDENTIFIED BY THE LETTER (a,b,c,...) WITHIN THE LIGHT FIXTURE. WHERE NO SWITCH APPEARED TO CONTROL THE

LIGHTS, THIS IS IDENTIFIED WITH A 'NS' DESIGNATION WITHIN THE LIGHT FIXTURE.

Donald L. Hopkins

PANEL 'L3'

PANEL 'L2

PANEL 'L4'

MAIN DISCONNECT

& 3-PANELS

E201

BUILDING 3303 LIGHTING PLAN

1/4"=1'-0"

E

Donald L. Hopkins

ROOM

VESTIBULE

ELEV

E1

STAIR

S1

ROOM

ELEV

E2

STAIR

S2

ROOM

ROOM

ELEV

E3

STAIR

S3

ROOM

ELEV

E4

STAIR

S4

ROOM

ELEV

E5

STAIR

S5

ROOM

ELEV

E6

STAIR

S6

ROOM

ELEV

E7

STAIR

S7

ROOM

ELEV

E8

STAIR

S8

ROOM

ELEV

E9

STAIR

S9

ROOM

ELEV

E10

STAIR

S10

ROOM

ROOM

ROOM

ROOM

E101

BLDG 1216 1ST FLOOR DEMO PLAN

3/16"=1'-0"

E101

BLDG 1216 4TH FLOOR DEMO PLAN

3/16"=1'-0"

E101

BLDG 1216 2ND FLOOR DEMO PLAN

3/16"=1'-0"

E101

BLDG 1216 5TH FLOOR DEMO PLAN

3/16"=1'-0"

E101

BLDG 1216 3RD FLOOR DEMO PLAN

3/16"=1'-0"

E101

BLDG 1216 6TH FLOOR DEMO PLAN

3/16"=1'-0"

E101

BLDG 1216 7TH FLOOR DEMO PLAN

3/16"=1'-0"

E101

BLDG 1216 8TH FLOOR DEMO PLAN

3/16"=1'-0"

E101

BLDG 1216 9TH FLOOR DEMO PLAN

3/16"=1'-0"

E101

BLDG 1216 10TH FLOOR DEMO PLAN

3/16"=1'-0"

E101 3/16"=1'-0"

E

GENERAL NOTES

1. THE NUMERICAL DESIGNATION IN THE LIGHT FIXTURE IS INTENDED TO DEPICT THE APPROXIMATE NUMBER OF T12 LAMPS WHICH WILL

NEED TO BE DISPOSED OF AS PART OF THE WORK; I.E F2 = 2-LAMPS, F3= 3 LAMPS, ECT...

Donald L. Hopkins

S1

ROOM

VESTIBULE

ELEV

E1

STAIR

S1

ROOM

ELEV

E2

STAIR

S2

ROOM

ROOM

ELEV

E3

STAIR

S3

ROOM

ELEV

E4

STAIR

S4

ROOM

ELEV

E5

STAIR

S5

ROOM

ELEV

E6

STAIR

S6

ROOM

ELEV

E7

STAIR

S7

ROOM

ELEV

E8

STAIR

S8

ROOM

ELEV

E9

STAIR

S9

ROOM

ELEV

E10

STAIR

S10

ROOM

ROOM

ROOM

ROOM

E201

BLDG 1216 1ST FLR LIGHTING PLAN

3/16"=1'-0"

E201

BLDG 1216 4TH FLR LIGHTING PLAN

3/16"=1'-0"

E201

BLDG 1216 2ND FLR LIGHTING PLAN

3/16"=1'-0"

E201

BLDG 1216 5TH FLR LIGHTING PLAN

3/16"=1'-0"

E201

BLDG 1216 3RD FLR LIGHTING PLAN

3/16"=1'-0"

E201

BLDG 1216 6TH FLR LIGHTING PLAN

3/16"=1'-0"

E201

BLDG 1216 7TH FLR LIGHTING PLAN

3/16"=1'-0"

E201

BLDG 1216 8TH FLR LIGHTING PLAN

3/16"=1'-0"

E201

BLDG 1216 9TH FLR LIGHTING PLAN

3/16"=1'-0"

E201

BLDG 1216 10TH FLR LIGHTING PLAN

3/16"=1'-0"

E201 3/16"=1'-0"

E

SPECIFIC NOTES

Donald L. Hopkins

SHOP

SHOP

OFFICE

BREAK

ROOM

STORAGE

OFFICE

OFFICE

RESTROOM

RESTROOM

MECH

ROOM

LOADING

BAY

PARTS

STORAGE

TOOL

ROOM

OFFICE

OFFICE

OFFICE

SHOP

STORAGE

PLAN

LAYOUT

NETWORK

111a

ROOM OPEN TO ABOVE

E101

BUILDING 1127 LIGHTING DEMO PLAN

1/8"=1'-0"

E

GENERAL NOTES

1. THE NUMERICAL DESIGNATION IN THE LIGHT FIXTURE IS INTENDED TO DEPICT THE

APPROXIMATE NUMBER OF T12 LAMPS WHICH WILL NEED TO BE DISPOSED OF AS PART

OF THE WORK; I.E F2 = 2-LAMPS, F3= 3 LAMPS, ETC...

Donald L. Hopkins

SHOP

SHOP

OFFICE

BREAK

ROOM

STORAGE

OFFICE

OFFICE

RESTROOM

RESTROOM

MECH

ROOM

LOADING

BAY

PARTS

STORAGE

TOOL

ROOM

OFFICE

OFFICE

OFFICE

SHOP

STORAGE

PLAN

LAYOUT

NETWORK

111a ROOM OPEN TO ABOVE

E201

BUILDING 1127 LIGHTING PLAN