Salient Characteristics Fitness Door REF: FA500019QA045
1. General requirement: To replace all four main entry door assemblies and associated hardware at the
Elmendorf Fitness Center, Building 9510, JBER. The doors will reuse the existing door frame, glass, and kits. The entryway is comprised of two paired openings, one side will be known as the electrified paired opening and the other the mechanical paired opening. One leaf of one paired opening functions as an automatic door; additionally this pair is also controlled via a card access system to provide secure access to authorized users. The installed doors and hardware must be compatible with the entry control system. The current doors utilize a top latch system and the facility would like to switch to a removable mullion on both paired openings.
2. Salient Characteristics quoted products must be equal or better to the following:
a. Electrified paired opening:
i. Quantity 2 – 3’-0” x 7’-0” (measurements to be confirmed by contractor)
ii. 16 gauge A60 galvanized and urethane foam injected doors
iii. Doors to have glass cutouts with steel reinforced perimeters.
iv. Dark bronze, geared, continuous hinges (one of the hinges must have integral power transfer)
v. Power supply shall be equal or better to a Von Duprin PS914 4-amp power supply with battery back-up kit
1. Output shall be 12 or 24 VDC selectable
2. Input shall be 120/240 VAC
vi. Mullion shall be a keyed removable mullion with stabilizers
vii. Electric door leaf locking mechanism shall be Von Duprin EL99TP-CD rim exit device with electrical latch reaction and a cylinder dogging and keyed thumb latch pull trim.
viii. Mechanical door leaf locking mechanism shall be a Von Duprin 99TP-CD rim exit device with cylinder dogging and keyed thumb latch pull trim.
ix. All locking cylinders shall be Best cylinder housings
x. The leafs shall have two overhead concealed stops set to a 110 degree swing.
xi. The mechanical leaf closer shall be equal or better to an LCN 4111 EDA parallel arm closer
xii. The electrical leaf closer shall be equal or better to an LCN Senior Swing series swing operator with wireless actuators.
1. The swing operator must have a push and release function that allows the door to function mechanically when a user manually opens the door without wireless switch activation.
xiii. The exterior meeting edges of the face of the door leafs shall have a brush astragals on each edge
xiv. A 10”x 36” bronze kick plate will be installed on each leaf
xv. The door shall come drilled and tapped for continuous hinges, exit devices, closer, concealed overhead stops.
xvi. All doors shall be painted with a minimum of two coats of silicone alkyd enamel paint equal or better to Rodda Powerkote
xvii. The door locking hardware shall have an inside release to ensure that building users of the facility after staffed hours can exit freely. The door release must be mechanical in nature and independent of electrical power.
xviii. In the event of a power outage doors shall remain locked.
b. Mechanical paired opening:
i. Quantity 2 – 3’-0” x 7’-0” (measurements to be confirmed by contractor)
ii. 16 gauge A60 galvanized and urethane foam injected doors
iii. Doors to have glass cutouts with steel reinforced glass perimeters.
iv. Dark bronze, geared, continuous hinges (one of the hinges must have integral power transfer)
v. Mullion shall be a keyed removable mullion with stabilizers
vi. Door leaf locking mechanisms shall be Von Duprin EL99TP-CD rim exit device with electrical latch reaction and a cylinder dogging and keyed thumb latch pull trim.
vii. All locking cylinders shall be Best cylinder housings
viii. The leafs shall have two overhead concealed stops set to a 110 degree swing.
ix. The mechanical leaf closers shall be equal or better to an LCN 4111 EDA parallel arm closer
x. The exterior meeting edges of the face of the door leafs shall have a brush astragals on each edge
xi. A 10”x 36” bronze kick plate will be installed on each leaf
xii. The door shall come drilled and tapped for continuous hinges, exit devices, closer, concealed overhead stops.
xiii. All doors shall be painted with a minimum of two coats of silicone alkyd enamel paint equal or better to Rodda Powerkote