Question and Answers Ground Support Equipment XFS 23

Dated 22 May 2023

Question 1: The specifications on the generators call for 50 Hz. Is this accurate. The U.S. uses AC power at 60 Hz, but most other countries use 50 Hz. I just want to be clear we are specifying the correct power generation at 50 Hz (50 cycles per minute).

Answer 2: This is accurate. We are looking at 50 Hz for our equipment.