Attachment_5_-_Construction_Data_Sheet_-_17_Jun_15.pdf
PDF 543 KB Posted
- Attached to
- CRU Flooring Bldg. 205 Federal contract opportunity
- Solicitation number
- FA4897-16-B-0006
About this file
Attachment 5 - Construction Data Sheet
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Abstract_FA4897-16-B-0006.pdf | ||
| FA4897-16-B-0006-0003.pdf | ||
| FA4897-16-B-0006-0002.pdf | ||
| Addendum__1 _2_August_2016.pdf | ||
| FA4987-16-B-0006-0001.pdf | ||
| Questions_and_Answers.pdf | ||
| Site_Visit_Meeting_Minutes_-_29_June_2016.pdf | ||
| Attachment_3_-_Wage_Determination_-_Building.pdf | ||
| Attachment_4_-_Grand_View_Gate_Information.pdf | ||
| Attachment_1_-_CRU_Floor _Hangar_205_Specifications.pdf | ||
| FA4897-16-B-0006_IFB.pdf | ||
| Attachment_6_-_Determination_of_Responsibility.pdf | ||
| Attachment_7_-_Certificate_of_Insurance.pdf | ||
| Attachment_2_-_Schedule_of_Material_Submittals.xls | XLS spreadsheet |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONSTRUCTION DATA SHEET
The following 18 pages are the Construction Data Sheet, required by Mountain Home Air Force Base. This document must be filled in and turned into the Contracting Office a minimum of 3 weeks prior to Final Inspection.
Construction Data Sheet is compiled of 4 sections:
Construction Data Sheet 01 33 00 Supplement pgs 1-14
Building Information 01 33 00 Supplement pgs 15-16
Real Property Installed Equipment 01 33 00 Supplement pg 17
Demolition / Removal of existing items from facility 01 33 00 Supplement pg 18
Attachment 5 FA4897-16-B-0006
Construction Data Sheet A B C D E F
5 Progress Payment:
6 Building/Facility No. Category Code Status of Worksheet:
7 Project Number Gross SF Interim 8 Project Title Type A & B Design Cost Beneficial Occupancy 9 Beneficial Occup Date Type C Services Final
10 Completion Date Total Construction Cost 11 Total Project Cost 12 Construction Project No. COTR:
13 Construction Contractor POC:
14 Design Contract No. Verified By:
15 Design Contractor 16 INDEX: Page No. Page No.
17 A. Heating Systems 2 11 G. Roadway Facilities / Other Pavements 18 B. Air Conditioning Systems 2,3 11 Curbs & Gutters 19 C. DDC (Direct Digital Control 3 11 Sidewalks 20 D. Fire Protections Systems & Security Alarm 4,5 12 Driveway 21 E. Fuel Tanks 6 12 Road 22 F. Base Infrastructure / Systems: 6 12 Parking 23 Electric 6,7,8 13 Storage Yard 24 Underground Ducts 8 13 Equip Pads 25 Cathodic Protection 8 13 H. Airfield 26 Gas Mains 8 13 Taxiway Lighting 27 Sewage & Waste 9 13 Apron 28 Water 10 14 Taxiway 29 Fence 11 14 Paved Shoulders
Building/Facility No.
Unit of Measure Quantity Category Code Total Cost
(include installation cost)
33 A. HEATING SYSTEMS:
HEATING FUEL OIL STORAGE
Tank used to store diesel for backup heating fuel GA X 821-112
HEATING PLANT
Provides government-owned generation of heat.
Plant capacity is in millions of British Thermal Units (MB). Please note MBs do not equal MBTUs. MBTUs are thousands of British Thermal Units. Covert MBTUs to MB by dividing by 1,000; example 50,000 MBTUs/1000 = 50 MBs.
A plant must have at least 1000 MBTUs (1 MB) to be reportable. MB X 821-115
37 B. AIR CONDITIONING SYSTEMS:
Related equipment such as air handling units, condensers, fans, pumps, etc., should be broken out with size and cost of the RPIE List. The costs for this related equipment, however, should be included in the cost shown here for the plant. Tons No. of Tons
A/C Plant 5 to 25 TN A package unit or unitary air conditioner consisting of one ore more factor made assemblies which includes an evaporator (cooling coil), a compressor and condenser combination and may include a heating (Heat Pump) function as well TN X 890-121
A/C Plant 25 to 100 TN A packaged unit or unitary air conditioner consisting of one or more factor made assemblies which includes an evaporator, compressor, condenser, and may include heating (heat pump) function as well (includes roof-top units) TN X 890-122
Building/Facility No.
Unit of Measure Quantity Category Code Total Cost
(include installation cost)
A/C Plant Over 100 TN Central Air Condition Plant that houses refrigeration equipment with capacities that meet or exceed 100 tons TN X 890-123
A/C Plant Less Than 5 TN A unitary air conditioner consisting of one or more factory-made assemblies which includes an evaporator (cooling coil), a compressor and condenser combination and may include a heating or dehumidification features TN X 890-125
43 (Amt of SF cooled) SF
A/C WINDOW UNITS
Self contained package units complete with compressor, evaporator, fan, and thermostat control and may include heating or dehumidification TN X 890-126
45 (Amt of SF cooled SF 47 C. DDC (Direct Digital Control)
DDC Field Equipment The necessary field interface devices and associated equipment necessary to tie into the central system for the purpose of controlling and monitoring energy use on the installation EA X 890-272
DDC Data Lines The data transmission system between the central station and the field interface equipment. LF X 890-273
Buildi ng/Facility No.
Unit of Measure Quantity Category Code
Total Cost (include installation cost)
D. FIRE PROTECTION
SYSTEMS
and SECURITY ALARM:
CLOSED HEAD AUTO
SPRINKLER
A component of a fire protection sprinkler system The closed head is opened when a fire melts the lead seal. Report amount of SF covered SF X 880-211
53 # of heads HD
OPEN HEAD DELUGE SYSTEM
Fire protection system currently installed in some existing aircraft hangars. This system is not authorized for new construction. Report amount of SF covered SF X 880-212
55 # of heads HD
PRE-ACTION SPRINKLER
SYSTEM
Automatic detector system which automatically releases water into the sprinkler system when a fire is detected. Report amount of SF covered SF X 880-216
57 # of heads HD
AFFF PA SPRINKLER SYSTEM
(Aqueous film forming form pre-action sprinkler system) - fire protection system consisting of piping, sprinkler heads, detection equipment, underwing nozzles, agent storage and proportioning system. Cost to include sprinkler system, detection system, underwing nozzles, agent storage and proportioning system but not additional water pumps, and/or storage. Report amount of SF covered SF X 880-217
59 # of heads HD
Buildi ng/Facility No.
Unit of Measure Quantity Category Code
Total Cost (include installation cost)
AUTO FIRE DETECTION SYSTEM
Cost to include automatic fire detection devices, circuits, or tubing connected circuitry, control panels, signal indicators, and other feature as required. Report amount of SF covered SF X 880-221
61 # of heads HD
MANUAL FIRE ALARM SYSTEM
(Interior) Fire protection system designed for alarming occupants within a building of a fire. Cost to include pull stations, bells, etc. EA (System) X 880-222
FOAM FIRE SYSTEM
Fire protection system required primarily in hangar type facilities for protection of high value resources EA X 880-232
OTHER FIRE SYSTEM
All other fire protection systems not found under specific category codes. Examples would be Halon 1211 or explosion suppression system, etc. EA X 880-233
DRY CHEMICAL SYSTEM
Fire suppression system with automatic fire detection capability and automatic discharge of fire suppression agent. This system is normally used for local application but may be used for special hazard total flood systems EA X 880-235
SECURITY ALARM SYSTEM Intrusion detection alarm system consist of electronic monitoring devices, detection devices, and associated transmission lines, power supplies, and signaling equipment EA X 872-841
Building/Facility No.
Unit of Measure Quantity Category Code Total Cost
(include installation cost)
68 E. FUEL TANKS / STORAGE TANK
OPERATING STORAGE, DIESEL
Storage tanks that provide an operating and reserve supply of diesel fuel GA (gallons) X 124-134
OPERATING STORAGE, JET
FUEL
Storage tanks that provide an operating and reserve supply of jet fuel GA E 124-135
OPERATING STORAGE, MOGAS
Storage tanks that provide an operating and reserve supply of motor gas GA X 124-137
PIPELINE, LIQUID FUELS
Fuel pipelines are provided for each different grade of fuel, except for cross country pipelines and offshore pipelines LF X 125-554
MISCELLANEOUS STORAGE
TANK
Those tanks used to store waste petroleum products or other type of liquid that is not considered hazardous waste and is not covered under other categories.
42 gals per BL (Barrels) X 890-171
75 F. BASE INFRASTRUCTURE/SYSTEMS:
76 ELECTRIC
ELECT EMERG/POWER GENERATOR
PLANT
Facility designed to provide emergency standby power is specified for essential facilities such as hospitals, airfield lighting, visual aids navigation, communications, and critical command KW E or X 811-147
Buildi ng/Facility No.
Unit of Measure Quantity Category Code
Total Cost (include installation cost)
PRIMARY DISTRIBUTION LINE
(OVERHEAD)
Utility component of the base electrical distribution system. The equipment includes poles, guys, crossarms, insulators, hardware, transformers, lightning arresters fuses, line switches and other related equipment LF E 812-223
79 Transformer KVA 80 Poles LF
PRIMARY DISTRIBUTION LINE
(UNDERGROUND)
Utility components of the base electrical system.
UG distribution primary line consists of ducts, manholes, vaults, cables, potheads, transformers, switches, protection devices, and associated equipment LF E 812-225
82 Transformer KVA
SECONDARY DISTRIBUTION LINE
(OVERHEAD)
Utility components of the base electric distribution system. Overhead secondary line conductors, insulators, service droops, control devices, and other related equipment LF E 812-224
84 Transformer KVA
SECONDARY DISTRIBUTION LINE
(UNDERGROUND)
Cost to include conductors, ducts, conduit, splice boxes, manholes, services, control and protective devices and associated equipment. LF E 812-226
86 Transformer KVA
Buildi ng/Facility No.
Unit of Measure Quantity Category Code
Total Cost (include installation cost)
EXTERIOR AREA LIGHTING
Applies to lighting for parking lots, streets, aircraft parking apron, aircraft alter areas, and security lighting for areas such as weapons storage, etc. EA E 812-926
88 (Mercury, Vapor, etc.) TYPE
90 UNDERGROUND DUCTS
TELEPHONE DUCT FACILITY
Ductwork for underground distribution of the telephone cable installed for reasons of protection and ease of expansions and additions. This application is normally used for the cable under pavements. LF E 135-583
UTILITY LINE DUCTS
Underground concrete encased ducts used for installation of electrical, telephone cable, optical communication lines, steam or hot water lines LF E 890-181
94 CATHODIC PROTECTION
CATHODIC PROTECTION SYSTEM
System designed to prevent corrosion of underground piping or other metallic objects and also used to prevent corrosion of metal storage tanks about and below ground EA E or X 890-269
97 GAS MAINS
GAS MAINS
Supply piping that runs from the central heat plant to the facilities requiring heat LF E 824-964
Buildi ng/Facility No.
Unit of Measure Quantity Category Code
Total Cost (include installation cost)
100 SEWAGE and WASTE
SEWAGE SEPTIC TANK
Cost to include sewage septic tank drain tile and piping servicing an individual facility generating domestic wastewater. KG E or X 831-169
INDUSTRIAL WASTE
TREATMENT & DISPOSAL
(Oil/Water Separator) Provides for treatment and disposal of waterborne wastes generated by existing industrial-type operations., I.e., corrosion control, plating, maintenance, photo processing, etc. KG E or X 831-155
INDUSTRIAL WASTE FLUID-
SPILL COLLECT
(Oil/Water Separator) Collects and separates spilled fuel and oil carried by surface water draining from large paved aprons used for aircraft refueling, truck and tanker unloading. KG E or X 831-157
SANITARY SEWAGE MAIN
Sewage collections mains serving the sanitary (domestic) wastewater treatment and disposal system LF E 832-266
STORM DRAIN DISPOSAL
Components of the storm drainage system to include piping, channels, catch basins, culverts, manholes, etc. LF E 871-183
Buildi ng/Facility No.
Unit of Measure Quantity Category Code
Total Cost (include installation cost)
107 WATER
WATER DISTRIBUTION MAINS
Potable/domestic water distribution piping between the water supply mains and the individual buildings LF E 842-245
WATER DISTRIBUTION MAINS
(IRRIGATION SYSTEMS ONLY)
Potable/domestic water distribution piping between the water supply mains and the individual buildings LF E 842-245
FIRE PROTECTION WATER MAIN
Water mains used exclusively to provide water from fire protection water storage and or pump stations to fire protection systems and/or fire hydrants LF E 843-314
FIRE HYDRANT
Facility used to supply water for the fire protection of buildings, structures, open storage, material, parked motor vehicles and aircraft, fuel handling points, etc. EA E 843-315
WATER FIRE PUMP STATION
Pumping stations that provide large volumes of water for fire protection. These systems are normally used in deluge systems which automatically call for large amounts of water when a fire occurs SF A 843-316
113 GM (gal per min)
FIRE PROTECTION WATER
STORAGE Water storage tanks used exclusively for supplying potable or non-potable water to fire protection systems KG (1000 gal) E 843-319
Building/Facility No.
Unit of Measure Quantity Category Code Total Cost
(include installation cost)
116 FENCE
SECURITY FENCE
Security fence/vehicle barriers - structure designed for protection of restricted or controlled areas or any area where threat of terrorism is imminent or likely
118 Chain-Link LF E 872-247 119 Frangible LF E 872-247
INTERIOR FENCE
Fences that promote personnel or traffic safety, operating efficiency, or environmental protection. This structure is not for security or boundary demarcation
121 Chain-Link LF E 872-248 122 Wood LF E 872-248 123 Masonry LF E 872-248
BOUNDARY FENCE
The legal and physical demarcation of an installation's boundary, usually defined by a fence
125 Chain-Link LF E 872-245
127 G. ROADWAY FACILITIES / OTHER PAVEMENTS
CURBS & GUTTERS
Concrete structures used to line streets and parking lots to aid in collection and control surface storm water runoff LF E 851-143 (4)
SIDEWALK
Hard surfaced walkways that enable more efficient means of pedestrian traffic. Report in both SY and LF
130 Concrete SY / LF E 852-289 (4) 131 Asphalt SY / LF E 852-289 (5) 132 Brick SY / LF E 852-289
Buildi ng/Facility No.
Unit of Measure Quantity Category Code
Total Cost (include installation cost)
DRIVEWAY
Private roads leading from a street or other thoroughfare to a building
134 Concrete SY E 851-145 (4) 135 Asphalt SY E 851-145 (5) 136 Gravel SY E 851-145
ROAD
Structures designed to carry vehicle traffic.
Volume and composition of traffic determines the design of roads and streets. Reportable in both SY and LF
138 Concrete SY / LF E 851-147 (4) 139 Asphalt SY / LF E 851-147 (5) 140 Gravel SY / LF E 851-147 141 Dirt SY / LF E 851-147
VEHICLE PARKING,
OPERATIONS
(Organizational) Parking space for government vehicles
143 Concrete SY E 852-261 (4) 144 Asphalt SY E 852-261 (5)
VEHICLE PARKING, OPERATIONS
(Non-Organizational) Parking space for privately owned vehicles
146 Concrete SY E 852-262 (4) 147 Asphalt SY E 852-262 (5)
REFUELER VEHICLE PARKING
Parking area designed for use by loaded refueling units and hydrant hose trucks that support the flying mission
149 Concrete SY E 852-269 (4)
Buildi ng/Facility No.
Unit of Measure Quantity Category Code
Total Cost (include installation cost)
AIRCRAFT SUPPORT EQUIP (ASE)
STOR YARD Facility designed for the storage of powered and non-powered support equipment that serve various repaired aircraft
151 Concrete SY E 852-273 (4) 152 Asphalt SY E 852-273 (5)
NON-RECOVERABLE SUPPORT
FACILITY, RELOCATABLE
Supporting slabs, foundations, grade beam, etc.
used to support modular structures, relocatable buildings, or other tent like structures that are not real property EA E 890-311
PAD, EQUIPMENT
General purpose concrete pad used to support communications equipment such as air conditioners, generator towers, etc. SY / EA E 132-123 (4)
PAD, POWER CHECK WITH
SUPPRESSOR
The power check pad with suppressor is the prim facility on which operational check of jet engines are performed. Unsuppressed pads are used in back-up or interim facilities. The suppressor and associated devices are supplied as items of government furnished equipment SY E 116-665 (4)
157 H. AIRFIELD
TAXIWAY LIGHTING
All lighting provided regularly used use taxiways LF E 136-667
APRON
Pavement provided for aircraft parking servicing and loading SY E 113-321
Buildi ng/Facility No.
Unit of Measure Quantity Category Code
Total Cost (include installation cost)
TAXIWAY
Pavement provided for ground movement of aircraft SY E 112-211
PAVED SHOULDERS
The shoulders of runways, taxiways, etc. SY E 116-642
BUILDING INFORMATION
Facility No. Project No. Contract No.
BLDG DIMENSIONS Length Width Gross SF Net SF Main Building Wings Basement Offsets Attic Porches, Covered Foundation Roof
OTHER BLDG DATA Linear Feet Ceiling Height Main Bldg Ceiling Height Basement Largest Door Height Largest Door Width
FIRE RATING CODE
CONSTRUCTION
Specify Type of Material
Used in Construction Foundations (Concrete, etc.)
Floors (Concrete, etc.)
Walls (Masonry, Metal Stud, etc.)
Roof (Standing Seam, EPDM, Other (identify)
BUILDING INFORMATION
UTILITY CONNECTIONS Number of pipes Diameter of each pipe
Capacity of all inlet pipes
Metered yes / no
Water Gas Sewer Storm Drainage Electrical
SYSTEM Energy Source Location Fuel Description Air Circulation Heating Air Conditioning Hot Water Electrical
ELECTRIC Phase Voltage Wire Size Connected Load -
AMPS / KVA
Signature Date:
Printed Name Phone:
Title of Preparer
A B C D E F G H I J K L M N O
1 REAL PROPERTY INSTALLED EQUIPMENT
2 BLDG NO. CONTRACTOR:
3 PROJECT NO. DATE:
4 CONTRACT NO. CONTACT NAME: PHONE NO:
DESCRIPTION QTY MFG MODEL/TYPE SIZE SERIAL NO. UNIT COST
EXACT LOCATION OF
EQUIP WARRANTY INFORMATION EQUIP LABELED REMARKS6
Factory Start Date
Warranty Years Contractor
Start Date Warranty
Years YES / NO
DEMOLITION / REMOVAL OF EXISTING ITEMS FROM FACILITY
BLDG NO. PROJECT NO. CONTRACTOR
CONTRACT NO. PHONE NO. DATE:
Real Property Installed Equipment Removed from Building
DESCRIPTION QTY MFG SIZE SERIAL NO.
LOCATION OF
EQUIP REMARKS
Pavements and Fence Structural
Type Unit of Measure Quantity Concrete, Asphalt, etc. Type Unit of Measure Materials Quantity
Sidewalk SY Roofs SF Curbs/Gutters LF Exterior Bldg SF Driveway SY Interior Bldg Walls SF Roads SY Other Parking Areas SY Fence LF Other
Underground Systems Exterior and Interior Electric Type Unit of Measure Quantity Removed or Abandonded in Type Unit of Measure Size/Voltage/Phase Quantity
Storm Sewer/Drainage System LF l Primary OH LF / / Water Distribution Mains LF Primary UG LF / / Sanitary Sewer System LF Secondary OH LF / / Gas Distribution Mains LF Secondary UG LF / / Other LF Interior Electric LF / /
Transformers KVA Phase Other
File details come from the government source that posted it. Updated .