RFI Log - MDG Card System 08152022.xlsx
XLSX spreadsheet 20 KB Posted
- Attached to
- Facility Access Control Program, ID Badge Card Reader System, & Maintenance Federal contract opportunity
- Solicitation number
- FA488722Q0054
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B1146- Vet Clinic Card Readers.pdf | ||
| Door Reader Drawings (1130 1135 1514).pdf | ||
| Badge Reader and Controller Locations.xlsx | XLSX spreadsheet | |
| Solicitation - FA488722Q0054.pdf | ||
| MDG Card System - Statement of Work.pdf | ||
| MDG Card System - RFI Log.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| REQUEST FOR INFORMATION LOG | ||||||||||||
| CONTRACT #: | SOLICITATION #: | |||||||||||
| TBD | FA488722Q0054 | |||||||||||
| SUBMITTED BY CONTRACTOR | TO BE COMPLETED BY GOVERNMENT | |||||||||||
| RFI # | DATE | DOCUMENT | SHEET / PAGE / PARA | DISCIPLINE | QUESTION / ISSUE | RESPONSE DATE | RESPONSE | POC | CHANGE TO SOLICITATION REQUIRED (YES OR NO) | DOCUMENT REVISED | QUESTION SUBMITTED BY | |
| OFFICE SYM | NAME | |||||||||||
| 001 | 8-Aug-22 | Statement of Work | Can the Government provide a complete list of the existing equipment that is be integrated with the new ACS? This should include all card readers, door sensors, request to exit devices, door locks, network infrastructure, and power supplies. | Please see attachment. | ||||||||
| 002 | 8-Aug-22 | Statement of Work | Due to current product lead times and the project installation duration, a 30-day completion window after award is not realistic. Can the Government extend this completion window to 90 days?. Can the Government provide a floorplan of each building to include all device locations? | 90 days is a little extensive for us. Do we know a product lead time? Include lead time and proposed work PoP in quote. See attachment for floorplans w/ locations. | ||||||||
| 003 | 8-Aug-22 | Statement of Work | Can the government provide a floor plan of each building to include all device locations? | See attachment for floorplans w/ locations. | ||||||||
| 004 | 8-Aug-22 | Statement of Work | Can the contractor reutilize the existing power and communication infrastructure? | I had stated to replace power supplies as well, but if they are in good condition and up to code, then we can use existing power supplies. | ||||||||
| 005 | 10-Aug-22 | Statement of Work | Can you provide a map of each building showing door locations? | See attachment for floorplans w/ locations. | ||||||||
| 006 | 10-Aug-22 | Statement of Work | Can you provide an overview map on where buildings 1135, 1146 & 1514 are in relation to building 1130? | See attachment. | ||||||||
| 007 | 10-Aug-22 | Statement of Work | Can you provide a total number of readers in each building? | Bldg 1130 - 76 (Current) Adding 2 |
Bldg 1135 - 1 (Current) Bldg 1514 - 2 (Current) Bldg 1146 - 4 (Current) Bldg 1141- 0 (Current) Adding 1
| 008 | 10-Aug-22 | Statement of Work | If there are more than 72 existing readers then you will need more than the 36 two reader controllers in the bid spec. | See above for current reader count. |
| 009 | 10-Aug-22 | Statement of Work | Is there a network connection available between all of the buildings? | Connected by private fiber loaned to MDG from Comm underground between buildings. These will be re-used. No network connection. |
| 010 | 10-Aug-22 | Statement of Work | If there is not a network connection between all of the buidlings we would not be able to program them on one software package. | No network connection. |
| 011 | 10-Aug-22 | Statement of Work | Can we use the exsiting wire, door locking hardware, and readers? | Badge readers are not being replaced. Contractor will need to provide new wire, locking hardware and readers for the 3 new additional readers. |
| 012 | ||||
| 013 | ||||
| 014 | ||||
| 015 | ||||
| 016 | ||||
| 017 | ||||
| 018 | ||||
| 019 | ||||
| 020 | ||||
| 021 | ||||
| 022 | ||||
| 023 | ||||
| 024 | ||||
| 025 | ||||
| 026 | ||||
| 027 | ||||
| 028 | ||||
| 029 | ||||
| 030 | ||||
| 031 | ||||
| 032 | ||||
| 033 | ||||
| 034 | ||||
| 035 | ||||
| 036 | ||||
| 037 | ||||
| 038 | ||||
| 039 | ||||
| 040 | ||||
| 041 | ||||
| 042 | ||||
| 043 | ||||
| 044 | ||||
| 045 | ||||
| 046 | ||||
| 047 | ||||
| 048 | ||||
| 049 | ||||
| 050 | ||||
| 051 | ||||
| 052 | ||||
| 053 | ||||
| 054 | ||||
| 055 | ||||
| 056 | ||||
| 057 | ||||
| 058 | ||||
| 059 |
File details come from the government source that posted it. Updated .