Attach_6_CAFB_Labeling_Standards__2009_Rev1.pdf

PDF 482 KB Posted

Attached to
Replace Primary and Secondary Electrical Distribution Phase 1 Federal contract opportunity
Solicitation number
FA4855-16-R-0005
Issued by
Department of the Air Force Special Operations Command

About this file

Attachment 6/ Labeling Standards

View the file

Other files for this federal contract opportunity

Other files attached to Replace Primary and Secondary Electrical Distribution Phase 1, newest first.
File Type Posted
Phase_1_Evaluation_Notification.pdf PDF
Atch_12_Update_SOO_6_April.pdf PDF
Amendment_4-_0005.pdf PDF
Atch_11_Update_SOO_6_April.pdf PDF
Amendment_3-0005.pdf PDF
Additional_Qa.pdf PDF
QA_Phase_1.2.pdf PDF
FA4855-16-R-0005-P00002.pdf PDF
Attachment_11_Performance_Reference_Form.doc DOC document
QA_Phase_1.pdf PDF
Amendment_1-_0005.pdf PDF
Attach_10_CAFB_MAFR.pdf PDF
Attachment_1-SOO.pdf PDF
Attach_9_FA485516r0005WageDet.pdf PDF
Attach_2_SOMS_CZQZ13_1134_Replace_primary_and_secondary_overhead_phase_1.pdf PDF
Attach_7_CAFB_Electrical_Standards__-_2014.pdf PDF
Released_Solicitation.pdf PDF
Attachment_4.pdf PDF
Attach_5_CAFB_Architectural_Compatibility_Guide-2012.pdf PDF
Attachment_3.pdf PDF
Attach_8_CAFB_Sustainable_Landscape_Development_Plan_-_2012.pdf PDF
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PATCH PANEL

TELECOMMUNICATIONS RACK

PORT ON PANEL

R1 -A -1

HORIZONTAL CABLES

TR1 - TR2

100 PR 24 AWG

CA01 301 - 400

CABLE NUMBER TERMINATED COUNT

TERMINATION LOCATIONS

CABLE SIZE

TR1 - TR2

12 FIBER MM

FO 01 1-12

TERMINATION LOCATIONS

FIBER CABLE NUMBER

SINGLE OR CABLE SIZE

CABLE GUAGE

FIBER TERMINATIONS

BUILDING BACKBONE CABLES

MMAC - 1 - X

R1 -A - X

TELECOMMUNICATIONS RACK PATCH PANEL

JACK NUMBER

DEVICE

CARD NUMBER

PORT NUMBER

PATCH CABLES

MULTIMODE

WARNING

IF THIS CLAMP OR CABLE

IS LOOSE OR MUST BE

REMOVED PLEASE CALL THE

BUILDING TELECOMMUNICATIONS

MANAGER

TMGB

TR1

ER1

TELECOMMUNICATIONS

MAIN GROUNDING

BUSBAR

TELECOMMUNICATIONS

ROOM

EQUIPMENT ROOM

GROUNDING

TBB

TGB

TGB

TBB

FA4855-16-R-0005 Attachment 6

OUTLET PORT

R1-A 1 2

PATCH PANEL LETTER

(Patch Panels will be lettered in order starting with A)

TELECOMMUNICATIONS RACK NUMBER

(Telecommunications Racks will be numbered numerically, starting with 1, i.e. R1, R2)

3 R1-A 4

JACK LOCATION LABELS

R1-A 1 2

R1-A 5 6

Jacks shall be arranged and labeled according to their location in a room. They shall be arranged clockwise in ascending order around the room while standing in the doorway looking into the room. Floor jack number arrangement should work in clockwise order, looking out the TR doorway. The 27 SOCS labeling scheme adheres to the requirements outlined in the TIA/EIA 606 telecommunication standard.

A

PATCH PANEL

NUMBER

OUTLET PORT

LOCATION

PATCH PANEL

SINGLE GANG

DOUBLE GANG

R1-A 3 4 R1-A

3 4 R1-A 7 8

OUTLET PORT

(Ports will be numbered according to port number on patch panel. Ports will be numbered consecutively per quad face plate.)

1 R1-A 2

100 PR 24 AWG

CA01 301 - 400

CABLE NUMBER TERMINATED COUNT

CABLE SIZE

FO Bxx- Bxx 1-12 MM or SM

Fiber Optic Cable I.D.

FIBER CABLE NUMBER SINGLE OR

CABLE GUAGE

FIBER TERMINATIONS

OUTSIDE PLANT CABLES

MULTIMODE

Slide Number 1
Slide Number 2
Slide Number 3

File details come from the government source that posted it. Updated .