Summary: Statement of Objectives (SOO) – Dive Support Trailer

This Statement of Objectives describes requirements for the 38th Rescue Squadron (RSQ) to procure a custom-built, enclosed bumper-pull dive support trailer to replace a structurally compromised existing trailer. The trailer must safely transport and support continuous diving operations in remote Continental United States (CONUS) locations while withstanding prolonged exposure to corrosive saltwater environments. Key operational objectives include equipment transport and secure storage for a full heavy dive loadout, mobile support platform functionality, command and control capabilities for mission planning, dedicated workspace for pre- and post-dive maintenance and inspections, and high durability with corrosion resistance.

The trailer specifications require nominal dimensions of 8.5 feet (W) × 32 feet (L) with minimum 8 feet interior height and 7 feet 6 inches clear opening height at the rear ramp door. The unit must carry a minimum 3,000 pounds of dedicated support equipment and utilize heavy-duty dual or triple torsion axles rated for the fully loaded gross vehicle weight. Interior requirements include waterproof non-slip flooring, a 6-inch water-resistant kickplate, base cabinetry, and extensive E-track cargo management systems (floor tracks running 32 continuous feet; driver-side and passenger-side wall tracks at 2-foot and 4-foot heights). Equipment accommodation must support 20 SCUBA tanks, two air compressors, 15 BCDs, dive weights, personal gear for 15 personnel, underwater search equipment, and maintenance tools. Specialized storage includes a dedicated wet-gear drying cage (34" × 70") with floor drain and hanging rod, and a generator housing (27" × 40" × 33" minimum) with heavy-duty slide-out tray. Electrical systems require standard RV-style 50-amp external hook-up capacity to simultaneously operate two air conditioning units, one electric air compressor, all lighting, and underwater equipment battery chargers, with minimum four interior and four exterior GFCI-protected receptacles. Climate control comprises insulated walls and ceilings with two air conditioning units. Plumbing includes an enclosed bathroom with sink and toilet, self-contained freshwater and waste holding tanks for off-grid operations, and an exterior washdown system with water hose connection integrated into the freshwater system.

View the file

Other files

File Type Posted
SF 1449-Dive Trailer.pdf PDF
Dive Trailer Questions and Answers.pdf PDF
SF 1449 Dive Trailer.pdf PDF
Provisions and Clauses - Dive Trailer.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Objectives (SOO)

1.0 Background

The 38th Rescue Squadron (RSQ) requires a dedicated dive support trailer to execute and sustain Continental United States (CONUS) diving operations. The current dive trailer has suffered catastrophic structural failures, including broken axles, and is no longer safe or capable of supporting mission requirements. To maintain operational readiness, efficiency, and safety, the 38th RSQ requires a replacement trailer configured to transport a full dive loadout. Furthermore, this asset must withstand frequent exposure to highly corrosive saltwater environments without structural or functional degradation.

2.0 Objectives

The contractor shall provide a specialized dive support trailer that meets the following overarching operational objectives:

• Equipment Transport & Secure Storage: Safely transport, organize, and secure a full heavy dive loadout to and from remote operational sites.

• Mobile Support Platform: Function as a self-contained, mobile support platform capable of sustaining continuous diving operations in remote and austere CONUS locations.

• Command & Control: Serve as a central command post for dive operations, providing a controlled, dedicated space for mission planning and execution.

• Maintenance & Inspection: Provide an organized, accessible workspace for pre-dive and post-dive equipment inspections, maintenance, and staging.

• Environmental Survivability: Ensure high durability and corrosion resistance to withstand prolonged exposure to salty, marine environments.

3.0 Specific Requirements

The contractor shall manufacture and deliver a custom-built, enclosed bumper-pull trailer meeting the following minimum specifications:

3.1 Chassis, Dimensions & Design

• Style: Enclosed Bumper Pull Trailer.

• Dimensions: Nominal 8.5' (W) x 32' (L) (or equivalent interior volume).

• Clearance: Minimum 8' interior height with a minimum 7'6" clear opening height at the rear ramp door.

• Payload Capacity & Axles: Rated to carry a minimum of 3,000 lbs of dedicated support equipment. The contractor must utilize a heavy-duty axle configuration (e.g., dual or triple torsion axles) explicitly rated to safely support the trailer's gross vehicle weight (GVWR) when fully loaded with all specified equipment, cabinetry, wet-facilities, and fluids.

• Protection: The trailer rear frame must be equipped with skid protection (e.g., steel bogey wheels, skid rollers, or heavy-duty skid plates) to prevent damage to the frame and rear bumper when traversing uneven terrain or steep transitions.

• Jacks & Stabilization: Power-operated tongue jack system featuring a dedicated, enclosed independent power source, complemented by heavy-duty rear stabilizer jacks.

• Spare Tires: Provide two (2) matching spare tires with heavy-duty mounting hardware (interior or exterior, provided they do not obstruct primary workspaces or cargo pathways).

• Exterior Color: Any color is acceptable.

3.2 Exterior & Access Doors

• Side Door: Minimum 48” width side door featuring locking capabilities and providing sufficient clearance for personnel and gear entry/exit.

• Cable Access Panel: Minimum 15" x 18" access door constructed of non-conductive material to support external cable routing during dive site operations.

3.3 Equipment Load & Dedicated Storage

The trailer's interior footprint must securely accommodate the operational loadout, including 20 SCUBA tanks, two (2) air compressors, dive weights/clumps, 15 BCDs, personal gear for 15 personnel, U/W search equipment, maintenance tools, and a freshwater dip tank. Special storage requirements include:

• Drying Cage: A dedicated wet-gear drying cage accessible from the exterior, measuring approximately 34" (D) x 70" (W) and matching the interior height of the trailer. This cage must be equipped with a floor drain and a rod to hang diving gear.

(see attached picture)

• Generator Housing: An area designed to house a generator, measuring a minimum of 27" (D) x 40" (W) x 33" (H). This housing must feature a heavy-duty slide-out tray to facilitate ease of maintenance and operation. (see attached picture)

3.4 Interior Outfitting & Cargo Management (E-Track)

• Flooring: Durable, waterproof, and non-slip flooring designed to protect the subfloor from water damage and heavy diving gear.

• Kickplate: Minimum 6-inch-high durable, water-resistant kickplate installed along all interior walls and the front of the base cabinet.

• Cabinetry: Base cabinet installed on the front interior wall.

• Cargo Management System: The trailer must utilize a heavy-duty, multi-point, flush-mounted horizontal cargo securing track system (comparable to horizontal E-track profile) to accommodate standard spring-loaded tie-down fittings.

• Floor Tracks: One (1) set of two (2) parallel flush-mounted tracks running 32 continuous feet along the trailer floor.

• Driver-Side Wall Tracks: One (1) set of two (2) parallel wall-mounted tracks running 32 continuous feet. (height 2 feet and 4 feet)

• Passenger-Side Wall Tracks: One (1) set of two (2) parallel wall-mounted tracks running 24 continuous feet. (height 2 feet and 4 feet)

3.5 Electrical Requirements & Lighting

• Power Input: Standard RV-style external hook-up rated for a minimum of 50 AMPS.

• Capacity: Electrical panel must simultaneously run two (2) A/C units, one (1) electric air compressor, all lighting, and battery chargers for U/W equipment. (see attached model of air compressor)

• Interior Outlets: Minimum of four (4) interior two-plug receptacles across the workspace, with at least two (2) dedicated to the primary countertop/base cabinet area.

• Exterior Outlets: Minimum of four (4) exterior-rated, weather-resistant GFCI-protected receptacles positioned to support multi-directional exterior operations.

• Lighting Configuration: LED lighting must support safe operation, loading, and interior visibility. Exterior lighting must be sufficient to illuminate the entire length of the passenger side and the rear of the trailer, extending outward to a distance of approximately 15 feet to support nighttime exterior operations.

3.6 Climate Control

• Insulation: Insulated walls and ceilings throughout the trailer.

• HVAC: Provide and install two (2) Air Conditioning units.

3.7 Plumbing & Facilities

• Bathroom: Enclosed bathroom featuring a sink and toilet.

• RV-Style Plumbing: Self-contained configuration including onboard freshwater and waste holding tanks to ensure facilities are fully operational at remote, off-grid sites.

• Washdown System: The trailer must be equipped with an exterior water hose connection (spigot/port) integrated into the freshwater system to allow personnel to hose down equipment after use and prior to storage.

Appendix A: Reference Photographs - Current Dive Trailer

- Drying Cage -

- Generator Housing -

- Interior

Installed Electric Compressor

Wall E-Track