This is a Questions and Answers document for solicitation FA48192Q0007 addressing clarifications on the Big Top Shelter Sustainment contract at Tyndall Air Force Base. The document resolves five key ambiguities regarding scope, frequency, and technical requirements. There is no incumbent contractor currently performing these services. Approximately 4,000 feet of existing sunshades from other manufacturers at Tyndall AFB are excluded from the scope of work. The Big Top shelters will be installed in a typical military flightline environment. Contrary to initial solicitation language, there are no doors or enclosing side/end walls on the structures, and the requirement for door and track maintenance has been removed from the revised Performance Work Statement.

The primary clarification concerns the contractor's service visit frequency. While the solicitation initially referenced "Annual Preventive Maintenance" alongside references to "bi-annual inspections" in the Statement of Work section 2.3.4, the amendment confirms the requirement is for annual maintenance and inspection visits. The Performance Work Statement dated March 9, 2026 has been revised to reflect this change, eliminating the semi-annual frequency language. This document serves as an amendment to the original solicitation and should be read in conjunction with the updated PWS to ensure clarity on all contractual obligations.

View the file

Other files

File Type Posted
Big Top Sustainment PWS 9 March 2026.docx DOCX document
Solicitation - FA481926Q0007.pdf PDF
Big Top Sustainment PWS 25 Feb.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Q & A for Big Top Shelter Sustainment - Solicitation FA48192Q0007 Q1: Is there an incumbent performing the requested services? What is the company name Answer: No Q2: There appears to be approximately 4,000 feet of existing sunshades at Tyndall AFB from a manufacturer other than BigTop. Are these to be included in the SOW?

Answer: No Q3: There are no BigTop shelters at Tyndall that are readily discernible via Google Maps but commercially available satellite imagery is often out of date. Are the Big Top shelters located within a typical military flightline environment?

Answer: Yes, this will be installed in a flightline environment Q4: Are there any doors or enclosing side/end walls? The Solicitation refers to sunshades versus enclosed structures with doors but SOW 2.2.e calls for maintenance of doors and tracks.

Answer: No, there are no doors and requirement for maintenance for doors has been removed. (Check revised PWS) Q5: Verify contractor service visit frequency. The Solicitation (all CLINS) calls for “Annual Preventive Maintenance …” but the Statement of Work ¶2.3.4 calls for “bi-annual inspections.” What is the contractor’s visit frequency requirement Answer: Requirment calls for annual maintenance and inspection. PSW has been revised to reflect the change.