FA480324QB028 Heat Treat Oven Questions and Answers.pdf
PDF 150 KB Posted
- Attached to
- Aircraft Metals Technology Heat Treat Oven
- Solicitation number
- FA480324QB028
About this file
This document contains a set of questions and answers related to a federal contract opportunity, solicitation number FA480324QB028, for the procurement and installation of a heat treat oven. The key details are:
The heat treat oven is required to process aluminum and various steel samples, with each sample not exceeding 40 lbs. The agency requires the oven to have a temperature range of 375°F to 900°F, but does not have specific heating or cooling rate requirements. The requested interior chamber size is 24" H x 24" W x 60" L, and the power requirement is for single-phase 230V. The agency's current process uses a circulating air and still air furnace. There is no specific delivery date requirement, but the oven is needed within 3 months. The agency does not anticipate volatile outgassing from the samples and does not have access to a Thermogravimetric Analyzer (TGA). The agency has not specified the required instrumentation type for the oven.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ques�ons and Answers, FA480324QB028
20 CONS / PKA
321 Cullen Street Atn: Lawrence Jenkins Shaw AFB, SC 29152-2610
Phone: (803) 895-9396 E-Mail Address: lawrence.jenkins.1@us.af.mil
08 April 2024
1. What is your sample material?
Aluminum and various steels
2. How heavy is each sample, and how many samples will be loaded at a �me?
It varies on a case-by-case scenario. Nothing over 40lbs
3. Do you expect vola�le outgassing?
No
a. If yes, do you have a TGA available?
No
4. What two temperatures would you choose for the TUS at our factory?
375* F and 900*F
5. Which instrumenta�on type is needed? (A / B / C / D / E)
Unknown
6. Do you have required hea�ng or cooling rates?
No required rates
7. Is 24" H x 24" W x 60" L the AMS cer�fied dimensions needed, or just the total chamber size? If total chamber size, the AMS cer�fied por�on of the chamber will be smaller.
Interior Chamber size
8. For the 230v, do you have access to three phase or only single phase?
Single
9. What is your current solu�on for this process?
Circula�ng air, and s�ll air furnace
10. Do you have specific delivery date requirements?
Nothing specific, within 3 months.
11. Do you know if the applica�on will consist of vola�le outgassing? If yes, how much? Is a TGA available?
Currently this is not something we are required