Attachment 4-Floor Plan.pdf

PDF 305 KB Posted

Attached to
Vindicator Intrusion Detection System Installation Federal contract opportunity
Solicitation number
FA480321QB085
Issued by
Department of the Air Force Air Combat Command

View the file

Other files for this federal contract opportunity

Other files attached to Vindicator Intrusion Detection System Installation, newest first.
File Type Posted
Attachment 7-Questions with Answers.pdf PDF
Attachment 6-Wall Sections.pdf PDF
Attachment 8_Vindicator Brand Name JA_Redacted.pdf PDF
FA480321QB085 Amendment 0001.pdf PDF
Attachment 5-Building Sections.pdf PDF
COMBOSOL-21QB085-Vindicator IDS Installation B1130 Annex.pdf PDF
Attachment 2-SOW Vindicator IDS Install B1130 Annex.pdf PDF
Attachment 1-Facility Drawing Bldg 1130 Annex redo.pdf PDF
Attachment 3-Base Pass Request.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

UP

A200

A201

A201

A200 2

A

E

(B

LA

ST

W

AL

L

C O

NS

TR

UC

T I O

N)

1'-

8"

206'-8"

2 3 4 5 6 7

D

B

C

W1

W1

W1

W1

W1

W1

W1

W1

W1

W1 W1 W1

W1 W1 W1

9'-5"16'-0"4'-0"8'-0"4'-0"16'-0"4'-0"8'-0"4'-0"74'-0"

1'-0"

(BLAST WALL CONSTRUCTION)

39'-5 1/8"

147'-5"

(T

YP

I C

AL

E

XT

ER

IO

R W

AL

L

CO

NS

TR

U C

TI

O

N)

1'-

4"

(TYPICAL EXTERIOR WALL

CONSTRUCTION)

EXISTING BUILDING

NEW ADDITION

BOILER ROOM

MECHANICAL

ELECTRICAL

A2R GENERAL

BRIEFING

EXECUTIVE VTC

STAIR "B"

FEMALE

MALE

ELEV EQUIP

SECURE COMM

VEST

FM -

COMPTROLLER

117 FSO

FMA

119 STAIR "A"

FSOD-

DISBURSING

122 FSOD- VAULT

FSOD-

WORKSTATION

FM

FMZ - SYS.

ADMIN

FMZ SERVER

FM TRAINING/

BOARDROOM

BOARD STAFF

SUITE

BOARD

SUPERVISOR

NON-BOARD

SUPERVISOR

OPS

SUPERVISOR

SITE MANAGER

BOARD VIP

OFFICE

BOARD VISIT

OFFICE

RECORDS

STORAGE

DPU

STAIR "C"

MEDAL SET -

GENERAL

STORAGE

MALE

FEMALE

SSO- SECURITY

OFFICE

A2 MAN TRAP

ADMIN

SUPERINT

OFFICE

A2

9TH AF OFFICE

A2 TRAINING

A2Y MOBILITY

STORAGE

A2Y GENERAL

DYNAMICS

A2Y SERVER

GREEN DOOR-

BREAK

SHARED VTC

A2F

A2F CHIEF

159 A2Y CHIEF

A2Y OFFICE

A2F NCOIC

NON-SCIF

SECURE COMM

CORRIDOR

A2F OPEN

OFFICE

A2Y OPEN

OFFICE

A2 CORRIDOR

A2X

ELEV "B"

ELEV "A"

FEMALE

SHOWER

MALE SHOWER

A341

SIM

A340

SIM

MECH UNIT IN ATFP

ENCLOSURE - SEE SHEET

A531 FOR DETAILS

8' TALL SCREEN WALL

W/ FACE BRICK & SPLIT

FACE CMU BASE ON

EXTERIOR SIDE - SEE

SHEET A400 FOR

EXTENTS

CONCRETE

STAIRS WITH

PAINTED GALV

STL HANDRAIL

RAMP DOWN

CANOPY

ABOVE

CONCRETE RAMP

WITH 6" HIGH BY 10"

WIDE CURB

INSULATED

COILING

DOOR

CANOPY

ABOVE

'-9

/2

'-1

1/ 2"

'-0

'-0

18'-0" 40'-0" 32'-0" 34'-6" 26'-0" 39'-0"

GEN DYN

OFFICE

IM

9TH AF

CEM

DA2

COMMAND

SECTION

'-0

/4

'-1

1/

4"

'-3

/4

'-1 1"

18'-9"

'-2

/8

8'-

1/

4"

'-3

'-1

1/

8"

'-1

/4

" 5'-

1/ 4"

'-4

8'-

1/

4"

'-1

1/

2"

'-7

/8

'-8

'-9

15 15

11 16

5'-0"

7'-0"

KITCHENETTE

5'-1"

JAN

4'- 9"

123A

117A

121A

120A

113B

113C 114A

113A

112A

126A

127A

129A

128A

134B

146A

154AD

157A

125A

100B

132A

141A139A138A

145A

133A

146B

156B

157B

144A143A

156C

103A

150A

136A

124A

116A

101A

156A

135A

8 15

I400

I400

I4004

I400 5

NEW EXISTING

BLDG

CORRIDOR

EXISITING

OFFICE

EXISTING

ENTRANCE

LOBBY

5'X10' RECESSED

WALK-OFF MAT

A300

A300

100A

WF

A502

A502

A502

A502

A402

A402

A402

A402

A352

A351

A350

A503

37'-10 1/4" 20'-7 5/8" 23'-9 3/8" 8'-6" 35'-1" 36'-8" 39'-6"

30'-1 1/4" 7'-9" 20'-7" 6'-0" 110'-6" 27'-1"

A503

A403

A401

FEC

FE

FE

FEC

FEC

FEC

FE

FEC

FEC

FEC

FEC

FEC

FEC

FEC

173B

134A

CJ

CJ

EXISTING STAIR

SERVER ROOM

169A

A503

A503

A503

A402

A341

(B

LA

S T W

AL

L

C O

SN

TR

UC

T I O

N)

'-1

1/

2"

A502

A503

A503

8'-9 3/4" 16'-3 1/4"

A502

TYP

A503

50'-4" 15'-4 7/8"49'-8"

11'-4" 32'-0" 12'-1" 8'-7"

A503

A340

A404

12'-4"

6'-11"

(BLAST WALL CONSTRUCTION)

60'-8 3/4"

(TYPICAL EXTERIOR WALL CONSTRUCTION)

145'-11 1/4"

(B

LA

S T W

AL

L

C O

NS

TR

UC

T I O

N)

'-1

1/

2"

NEW CASED

OPENING - SEE

SHEET A404

8'- 8"

8'- 0"

4'- 0"

'-0

4'-

0" 8'-

0" 4'-

0" 8'-

0" 4'-

0"

'-0

4'- 0"

8'- 0"

4'- 0"

8'- 0"

8'- 8"

ELEC

EQUIPMENT -

SEE ELEC

FE

FEC

HVAC UNITS

- SEE MECH

CANOPY ABOVE

9'-4" 2'-0" 4'-0" 2'-0" 4'-0" 2'-0" 4'-0" 2'-0" 4'-0"

1'-0 1/2"

4'-0"

8'-

2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 4'-

0" 2'-

0" 8'-

9'-3" 2'-0" 4'-0" 2'-0" 4'-0" 2'-0" 4'-0" 2'-0" 4'-0" 2'-0" 4'-0" 2'-0" 4'-0" 8'-0" 6'-0" 16'-0" 6'-0" 8'-0" 4'-0" 8'-0" 4'-0" 8'-0" 4'-0" 8'-0" 4'-0" 8'-0" 4'-0" 8'-0" 4'-0" 8'-0" 4'-0" 8'-0" 4'-0" 8'-0" 4'-0" 8'-0" 9'-5"

CJ

172A

102A

SSO OFFICE

7"

7'-4"

ADA

SL

O

PE

8'-6 7/8"

'-7

/4

'-5

/4

'-8

5'-

3/

4"

'-3

1'-3 1/4"

10'-6 1/8"

1'-2"

13'-1 5/8"

1'-2"

10'-6 1/8"

1'-3 1/4"

10'-0" 13'-11 5/8" 7'-6 1/4"

4'-5" 22'-10 3/8"

6'-

1/ 8"

I400

A402

WF

ADA

13 33

13'-2 1/8"

161A

165A

18'-8 1/4"

12'-6 1/8" 8'-5"

162A

142A

10'-1 3/8"

148A

PAINT CURB

OSHA YELLOW 1

ASI-2

5'-0"

CR

U

CR

U

NET-

APPS

NET-

APPS

HOT

COLD

HOT

COLD

4'

- 6

3'

- 6

4'

- 7

3'

- 6

4'

- 9

3'

- 6

4'

- 7

/4

49' - 11 1/8"

WORKSTATION

WORKSTATION

SCIF PERIMETER

1. SEE A601 & A602 FOR PARTITION TYPES

2. ALL DIMENSIONS TAKEN FROM FACE OF FINISH

MATERIAL

3. SEE A600 FOR OPENING SCHEDULE

4. SEE I300 & I301 FOR DEMOUNTABLE PARTITION

PLANS & FURNITURE WORKSTATIONS

5. SEE LIFE SAFETY SHEETS AND PARTITION

TYPES FOR LOCATIONS OF RATED WALLS

6. FIRST FLOOR EXTERIOR WALLS IN THE SCIF

AREA TO RECEIVE WWF AND HAVE 16 GA MTL

STUDS PER DCID 6/9 - SEE WALL SECTIONS FOR

MORE INFORMATION

GENERAL NOTES

LEGEND

PERMANENT WALL

NON RAISED FLOOR

RAISED ACCESS FLOORING

DEMOUNTABLE WALL

TYPICAL EXTERIOR WALL

CONSTRUCTION

BLAST WALL CONSTRUCTION

FURNITURE WALL

1. ALL OPENINGS IN WALLS TO BE SEALED PER

OPEN STORAGE GUIDELINES.

2. ADJUST LIGHT FIXTURES, SMOKE DETECTORS,

STROBES, MECHANICAL FIXTURES, ETC. AS

REQUIRED.

3. ALL DOORS ENTERING THE OPEN STORAGE

CLASSIFICATION WILL REQUIRE A HEAVY-DUTY

AUTOMATIC DOOR CLOSER AND CIPHER LOCK.

OPEN STORAGE

GENERAL NOTES

OPEN STORAGE PERIMETER

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G C

O M

M

AN

D

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

CHK

OF

A/E PROJECT NO.:

AD

D

/A

LT

ER

U

SA

FC

EN

T

H

EA

D Q

U

AR

TE

R

S

Sh aw

A ir

Fo rc e Ba se Su m te r, So ut h

C ar ol in a

N69450-09D-1280-0002

A s-

B ui lt

As indicated

A110

BU

IL

DI

NG

A

DD

IT

IO

N

FL

OO

R

PL

AN

1S

T

FL

OO

R

9 AUGUST 2013

VBRKLK

10-062

MEL

15057484

3/32" = 1'-0"A200 A110

1 1ST FLOOR - FINISH FLOOR

0' 4' 8' 16' 32'

SCALE: 3/32"=1'-0"

N

File details come from the government source that posted it. Updated .