Attachment 3 - Questions and Answers - FA480026Q0061.pdf
PDF 72 KB Posted
- Attached to
- JLG Lift Repair
- Solicitation number
- FA480026Q0061
About this file
This is a Questions and Answers document for solicitation FA480026Q0061, a JLG Lift Repair project issued by the Department of the Air Force Air Combat Command. The document clarifies technical and logistical details regarding the repair of a JLG 600S Telescopic Boom Lift to be performed at Langley Air Force Base. Key clarifications include: the government will cover transportation within a 50-mile radius of Langley AFB, while the contractor assumes responsibility for distances exceeding 50 miles; the equipment is currently mobile and can move under its own power; replacement tires are 39 X 15-22.5 BLACKSTONE OTR pneumatic-filled units for the left front and rear positions and right rear position; a full hydraulic system flush is required rather than only topping off fluid levels; and water contamination is limited to the control panel, not the hydraulic system itself.
Additional clarifications address repair scope and responsibility allocation: the swing control valve requires replacement per Section 3.1 of the Statement of Work; any latent defects discovered during testing and the required 30-minute load test will be addressed through formal contract modification at government expense; and the government assumes financial responsibility for additional repairs beyond the specified work if the initial repairs fail to restore full functionality. The questions document confirms that a certified technician previously diagnosed the equipment and that no other issues beyond those documented are known to exist. This is a Total Small Business set-aside solicitation with a response due date of June 8, 2026.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions and Answers JLG Lift Repair - FA480026Q0061
1. Does the forklift only have the issues stated in the document?
a. There are no other issues that we are aware of.
2. Was this piece of equipment previously diagnosed properly?
a. Yes, diagnosed by a certified technician.
3. If the items mentioned in the PDF are replaced and repaired, but the equipment still does not work, who is responsible for the cost of repairs at that point?
a. The government will be responsible for the cost of additional repairs.
4. Logistics & Transport: Is the Government or the Contractor responsible for the round-trip transportation, rigging, loading, and hauling of the boom lift between Langley AFB and the contractor's repair facility?
a. The Government will be responsible for trans, rigging, loading, and hauling within a 50 miles radius of Langley AFB.
b. Any requirement greater than 50 miles will be the responsibility of the contractor to transport equipment from Langley (1334 Durand Rd, Langley AFB, 23665) to contractor’s repair location.
5. Asset Mobility: Does the unit's engine currently start and run? Is the machine capable of moving onto a transport trailer under its own power, or is it completely immobilized requiring heavy recovery winching?
a. Yes, the unit’s engine does start, run and can move under its own power.
6. Tire Requirements: Please provide the exact OEM specification, tire type, and filling requirements (e.g., pneumatic vs. foam-filled) for the three replacement tires outlined in Section 3.4. price has OEM tires could vary depending on type.
a. 39 X 15 -22.5 BLACKSTONE OTR /STABILIZER/ pneumatic filled
7. Hydraulic System Contamination: Given that Section 3.2 identifies water-contaminated electronic controls, has water contamination migrated into the hydraulic fluid system?
a. No, water has only infiltrated the control panel.
8. Does the SOW require a comprehensive system flush, or only topping off to specified levels per Section 3.5?
a. Yes, a full system flush is required.
9. Latent Defects & Acceptance Testing: Because this is a Firm-Fixed-Price effort, if the contractor successfully installs all parts listed in Section 3.0 but during testing and/or final 30-minute load test reveals additional, unlisted component failures
(e.g., hidden main pump or other hydraulic/electronics related damages or corrosion due to water contamination), will those additional repairs be handled via a formal contract modification?
a. Yes.
10. Can the boom lift be driven on a trailer for transport?
a. Yes.
11. Please clarify in section 3.1 of SOW – which directional control valve needs to be replaced?
a. Swing control valve.
12. Please clarify in section 3.4 of SOW - which 3 tires need to be replaced?
a. Left - front and rear tire
b. Right - rear tire only. (The right front tire is brand new)