Fort Eustis BLDG 2305.pptx
PPTX presentation 8 MB Posted
- Attached to
- Security Alarms & Installation Federal contract opportunity
- Solicitation number
- FA480024Q0041
About this file
This document appears to be a Solicitation for a security alarm and installation requirement at Fort Eustis, Virginia. The scope includes planning, procuring, and installing a Dismount Access Control System (DAMS) in multiple buildings. The contractor will provide all labor, equipment, and materials required to deliver a complete and usable DAMS. The work must comply with applicable documents, construction codes, and federal wage laws. The contractor must provide personnel with relevant certifications and training on the installed system. All cabling must be properly installed, and the contractor must clean up debris daily. A one-year warranty for labor is required, plus two additional years at-cost, and the alarms have a 5-year warranty. Quotes are due by 11:00 AM EST on September 13, 2024, and should be sent to Senior Airman Naomi Rants. The solicitation is issued by the Department of the Air Force Air Combat Command.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Site Visit Instructions.docx | DOCX document | |
| Fort Eustis Base Access Form.pdf | ||
| Solicitation - FA480024Q0041 Final.pdf | ||
| Eustis DAMS SOR - 2301 2303 2304 2305 2307 2308.docx | DOCX document | |
| Synopsis FA480024Q0041.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DC
C C C C C C
F
H
J
J.2
K
L
M
J.8
STAIRS #1
CORRIDOR
CORRIDOR 1112
3PN
2PN
LAUNDRY 1035
LAUNDRY 1033
DAY ROOM (MEDIA)
DAY ROOM (GAMES)
CUST.
1110K
JAN.
1112A
LAB CLOS. 1036A
DRYER CLO
1035A
CORRIDOR 1110
MATCHLINE -
SEE SHEET EY112
SEE SHEET EY112
ELEC CLO 1111A
E
LEARNING LAB
US Army Corps of Engineers ®
SIZE: ANSI 'D'
G F E D C B
CONTRACT NO.:
DATE & TIME STAMP:
2/18/2020 2:46:34 PM
US ARMY CORPS OF ENGINEERS
NORFOLK DISTRICT NORFOLK, VA
DESIGNED BY:
R. KUSTOWSKI
DRAWN BY:
E. MORTON
CHECKED BY:
R. KUSTOWSKI
SUBMITTED BY:
R. NAGEL
ISSUE DATE: MARCH 2020 SOLICITATION NO.:
RTA SUBMITTAL
BCOF - FIRST FLOOR PLAN - AREA 'A' - SECURITY
JBLE - FORT EUSTIS, VIRGINIA
AIT BARRACKS COMPLEX PHASE 4 - BCOF
PN 073391
NAO FILE NO.: 794
SCALE: 1/8" = 1'-0"
BCOF - FIRST FLOOR PLAN - AREA 'A' - SECURITY
KEY PLAN
'A' 'C' 'D' 'B'
| DATE |
| DESCRIPTION |
| MARK |
A
SHEET ID
NO SCALE PLAN NORTH
BCOF
EY111
0' 8' 16' 24'
SCALE: 1/8" = 1' - 0"
RED SQUARES are DOOR ALARM LOCATIONS.
C C C C C C C C
DC
DC DC
DCDC
O
N
VEST.
CO
XO SGT
WAITING ROOM
1ST SGT
WOMENS
STOR.
1012A
TELECOM
TELECOM
PROFILE RECOVERY
STAIRS #3
ELEV.
STAIRS #2
PROFILE RECOVERY
PLT SGT
LOBBY
RECYC.
WAITING ROOM
MENS
CO
XO SGT
STOR.
1002A
BA. 1016A
1ST SGT
BA. 1052A
CORRIDOR
CORRIDOR
SEE SHEET EY114
MATCHLINE -
SEE SHEET EY114
MATCHLINE -
SEE SHEET EY113
MATCHLINE -
SEE SHEET EY113
MATCHLINE -
SEE SHEET EY111
MATCHLINE -
SEE SHEET EY111
MATCHLINE -
C E
SHOWER
1006A
SHOWER 1011A
CATV
1002B
2. IDS-1 REMOTE ANNUNCIATOR (GFGI). PROVIDE (1) 1-INCH CONDUIT (WITH PULL STRING) TO THE IDS-1 PANEL (GFGI) IN ROOM 1035B. SEE SHEET EY114 FOR LOCATION AND SHEET EY701 (DOOR MONITORING SYSTEM (IDS-1) RISER DIAGRAM) FOR ADDITIONAL REQUIREMENTS.
3. IDS-2 REMOTE ANNUNCIATOR (GFGI). PROVIDE (1) 1-INCH CONDUIT (WITH PULL STRING) TO THE IDS-2 PANEL (GFGI) IN ROOM 1035B. SEE SHEET EY114 FOR LOCATION AND SHEET EY701 (IDS-2 RISER DIAGRAM) FOR ADDITIONAL REQUIREMENTS.
TELECOMMUNICATIONS NOTES (EY112): #
1. CCTV MONITORING EQUIPMENT (GFGI). PROVIDE (1) 1-INCH CONDUIT (WITH PULL STRING) FROM THE CCTV MONITORING EQUIPMENT (GFGI) IN ROOM 1016 TO EACH CCTV EQUIPMENT RACK / CABINET (GFGI) IN ROOM 2005. SEE SHEET EY122 FOR LOCATION AND SHEET EY702 (CCTV RISER DIAGRAM) FOR ADDITIONAL REQUIREMENTS.
G F E D C B
BCOF - FIRST FLOOR PLAN - AREA 'B' - SECURITY
JBLE - FORT EUSTIS, VIRGINIA
AIT BARRACKS COMPLEX PHASE 4 - BCOF
PN 073391
| ISSUE DATE: | ||||
| MARCH 2020 | SOLICITATION NO.: | CONTRACT NO.: | NAO FILE NO.: 794 | DATE & TIME STAMP: |
2/18/2020 2:46:41 PM
| DESIGNED BY: | ||
| R. KUSTOWSKI | DRAWN BY: | |
| E. MORTON | CHECKED BY: | |
| R. KUSTOWSKI | SUBMITTED BY: |
R. NAGEL
SIZE:
ANSI 'D'
| US ARMY CORPS OF ENGINEERS | ||
| NORFOLK DISTRICT NORFOLK, VA | RTA SUBMITTAL |
BCOF - FIRST FLOOR PLAN - AREA 'B' - SECURITY
'C' 'D' 'B'
| DATE |
| DESCRIPTION |
| MARK |
SHEET ID
NO SCALE PLAN NORTH
BCOF
EY112
0' 8' 16' 24'
C C C
LAUNDRY
LAUNDRY
STAIRS #4
DAY ROOM (MEDIA) 1070
DAY ROOM (GAMES) 1068
1115A
LAB CLOS.
1072A
ELEC CLO
1114A
1113K
1071A
MATCHLINE -
C E
LEARNING LAB 1072
G F E D C B
BCOF - FIRST FLOOR PLAN - AREA 'C' - SECURITY
JBLE - FORT EUSTIS, VIRGINIA
AIT BARRACKS COMPLEX PHASE 4 - BCOF
PN 073391
| ISSUE DATE: | ||||
| MARCH 2020 | SOLICITATION NO.: | CONTRACT NO.: | NAO FILE NO.: 794 | DATE & TIME STAMP: |
2/18/2020 2:47:01 PM
| DESIGNED BY: | ||
| R. KUSTOWSKI | DRAWN BY: | |
| E. MORTON | CHECKED BY: | |
| R. KUSTOWSKI | SUBMITTED BY: |
R. NAGEL
SIZE:
ANSI 'D'
| US ARMY CORPS OF ENGINEERS | ||
| NORFOLK DISTRICT NORFOLK, VA | RTA SUBMITTAL |
BCOF - FIRST FLOOR PLAN - AREA 'C' - SECURITY
'C' 'D' 'B'
| DATE |
| DESCRIPTION |
| MARK |
NO SCALE PLAN NORTH
0' A
SHEET ID
BCOF
EY113
8' 16'
C C C C C C C C C C C C C C
DS KP
MS
KP DS
MS
DC
DC DC
DC DC
DC DC
DC DC
DC
DCDC
DC DC
DC
DC DC
DC DC
DC
DC DC
DC
B
D
MECHANICAL
ELECTRICAL
COMPANY SUPPLY
WOMENS
MENS
ARMS VAULT
VEST.
STOR.
SCRUB ROOM
STOR.
STOR.
SCRUB ROOM
STOR.
VEST.
ARMS VAULT
CORRIDOR
MENS
WOMENS
COMPANY SUPPLY
A/V ROOM
CORRIDOR
A/V ROOM
MULTI-PURPOSE
B
MULTI-PURPOSE
A
MULTI-PURPOSE D
MULTI-PURPOSE
E
MULTI-PURPOSE F
MULTI-PURPOSE C
E.S.S.
1035B
FIRE
1035C
MATCHLINE -
SEE SHEET EY112
EY401
C E
A/V ROOM
A/V ROOM
STOR.
G F E D C B
BCOF - FIRST FLOOR PLAN - AREA 'D' - SECURITY
JBLE - FORT EUSTIS, VIRGINIA
AIT BARRACKS COMPLEX PHASE 4 - BCOF
PN 073391
| ISSUE DATE: | ||||
| MARCH 2020 | SOLICITATION NO.: | CONTRACT NO.: | NAO FILE NO.: 794 | DATE & TIME STAMP: |
2/19/2020 3:56:03 PM
| DESIGNED BY: | ||
| R. KUSTOWSKI | DRAWN BY: | |
| E. MORTON | CHECKED BY: | |
| R. KUSTOWSKI | SUBMITTED BY: |
R. NAGEL
SIZE:
ANSI 'D'
| US ARMY CORPS OF ENGINEERS | ||
| NORFOLK DISTRICT NORFOLK, VA | RTA SUBMITTAL |
BCOF - FIRST FLOOR PLAN - AREA 'D' - SECURITY
SCALE: 1/8" = 1'-0"
| DATE |
| DESCRIPTION |
| MARK |
'D' 'B'
0' A
SHEET ID
BCOF
EY114
8' 16'
DC
C C C
STAIRS #1
LAUNDRY 2024
LAUNDRY 2022
DAY ROOM (MEDIA)
CORRIDOR 2078
CORRIDOR 2077
DAY ROOM (GAMES)
2079K
2077A
LAB CLOS. 2025A
ELEC CLO 2078A
2024A
CORRIDOR 2079
SEE SHEET EY122
SEE SHEET EY122
LEARNING LAB
SIZE: ANSI 'D'
G F E D C B
CONTRACT NO.:
DATE & TIME STAMP:
2/18/2020 2:47:34 PM
US ARMY CORPS OF ENGINEERS
NORFOLK DISTRICT NORFOLK, VA
DESIGNED BY:
R. KUSTOWSKI
DRAWN BY:
E. MORTON
CHECKED BY:
R. KUSTOWSKI
SUBMITTED BY:
R. NAGEL
ISSUE DATE: MARCH 2020 SOLICITATION NO.:
RTA SUBMITTAL
BCOF - SECOND FLOOR PLAN - AREA 'A' - SECURITY
JBLE - FORT EUSTIS, VIRGINIA
AIT BARRACKS COMPLEX PHASE 4 - BCOF
PN 073391
NAO FILE NO.: 794
BCOF - SECOND FLOOR PLAN - AREA 'A' - SECURITY
'D' 'B'
MARK
DESCRIPTION
DATE
0' A
SHEET ID
BCOF
EY121
8' 16'
DN
C C C C
DC
DC
DC DC
O
N
LOBBY
STAIRS # 2
STAIRS # 3
ELEC
TELECOM
LUGGAGE
TELECOM
ELEV.
CORRIDOR
CORRIDOR
MATCHLINE -
SEE SHEET EY123
MATCHLINE -
SEE SHEET EY123
MATCHLINE -
SEE SHEET EY121
SEE SHEET EY121
TELECOMMUNICATIONS NOTES (EY122): #
1. CCTV EQUIPMENT RACK / CABINET (GFGI). PROVIDE (1) 1-INCH CONDUIT (WITH PULL STRING) FROM CCTV EQUIPMENT RACK / CABINET (GFGI) IN ROOM 2005 TO THE CCTV MONITORING EQUIPMENT (GFGI) IN ROOM 1016. SEE SHEET EY112 FOR LOCATION AND SHEET EY702 (CCTV RISER DIAGRAM) FOR ADDITIONAL REQUIREMENTS.
G F E D C B
BCOF - SECOND FLOOR PLAN - AREA 'B' - SECURITY
JBLE - FORT EUSTIS, VIRGINIA
AIT BARRACKS COMPLEX PHASE 4 - BCOF
PN 073391
| ISSUE DATE: | ||||
| MARCH 2020 | SOLICITATION NO.: | CONTRACT NO.: | NAO FILE NO.: 794 | DATE & TIME STAMP: |
2/18/2020 2:47:40 PM
| DESIGNED BY: | ||
| R. KUSTOWSKI | DRAWN BY: | |
| E. MORTON | CHECKED BY: | |
| R. KUSTOWSKI | SUBMITTED BY: |
R. NAGEL
SIZE:
ANSI 'D'
| US ARMY CORPS OF ENGINEERS | ||
| NORFOLK DISTRICT NORFOLK, VA | RTA SUBMITTAL |
BCOF - SECOND FLOOR PLAN - AREA 'B' - SECURITY
'B' 'C' 'D'
| DATE |
| DESCRIPTION |
| MARK |
0' A
SHEET ID
BCOF
EY122
8' 16'
DN
This is the start of the file's text. The full file is on GovTribe.