This document is a Salient Characteristics specification sheet for a Mobile Breathing Air Compressor System Trailer. The comprehensive specification details 14 key requirements for a high-pressure breathing air compressor system designed for emergency and professional use. Critical specifications include a compressor capable of delivering at least 6000 PSI to fill SCBA cylinders, meeting NFPA 1989 breathing air quality standards, with a minimum flow rate of 13 SCFM, and a multi-stage filtration system that includes moisture and oil separators and CO/CO2 removal.
The system must be mounted on a weather-resistant trailer compliant with DOT regulations, featuring an engine-driven or electric motor option suitable for stationary and mobile use. Additional requirements encompass a cascade storage system with at least two 6000 PSI cylinders, an efficient cooling system, a user-friendly digital control panel, comprehensive safety features, and certifications meeting OSHA, NFPA, and ANSI standards. The specification also mandates on-site training, comprehensive user manuals, easy maintenance access, and a minimum one-year warranty on parts and labor, indicating a robust and professional-grade breathing air compressor system.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ FA466125Q0222 - Mobile breathing Air recharging system - Copy.docx | DOCX document | |
| RFQ FA466125Q0222 - Mobile breathing Air recharging system.docx | DOCX document | |
| FA466125Q0222 - FAR Provisions and Clauses.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Mobile Breathing Air Compressor System Trailer
Salient Characteristics
ITEM
NUMBER
DESCRIPTION QUANTITY UNIT
01 Compressor:
Must be high-pressure breathing air compressor capable of delivering at least 6000 PSI to fill SCBA cylinders.
1 EA
02 Air Quality:
System must provide air quality that meets or exceeds the NFPA 1989 standard for breathing air quality.
1 EA
03 Capacity:
Must have a minimum flow rate of 13 SCFM (Standard Cubic Feet per Minute)
1 EA
04 Filtration System:
Should include a multi-stage filtration system with moisture separators, oil separators, and CO/CO2 removal.
1 EA
05 Storage Cylinders:
Should be equipped with a cascade storage system capable of holding at least 2 cylinders each with a capacity of 6000 PSI.
1 EA
06 Trailer Specifications:
Mounted on a weather-resistant trailer, equipped with appropriate lighting, reflectors, and braking system as per DOT regulations.
1 EA
07 Power Source:
Must include an engine-driven or electric motor option, suitable for both stationary and mobile use.
1 EA
08 Cooling System:
Should have an efficient cooling system to ensure continuous operation in high-temperature environments.
1 EA
09 Control Panel:
User-friendly control panel with digital readouts for pressure, temperature, and operational status.
1 EA
10 Safety Features:
Include automatic shut-off, pressure relief valves, and emergency stop mechanisms.
1 EA
11 Certification:
Must be certified to meet or exceed OSHA, NFPA, and ANSI standards for safety and performance.
1 EA
12 Maintenance and Service:
Easy access for maintenance with recommended service intervals and parts readily available.
1 EA
13 Training and Support:
Provide on-site training for operators and maintenance personnel, along with comprehensive user manuals.
1 EA
14 Warranty: 1 EA